| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹36.9 L+₹47,687.86 (1.31%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹36.9 L+₹48,204.90 (1.32%)Rejected-Finance A P NIMGAON DAKU TAL KARJAT DIST AHMEDNAGAR | KARJAT | AHMEDNAGAR | MAHARASHTRA | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹40.6 L+₹4.2 L (11.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Mar 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Prakash G Kalekar AGE(Contracts)
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIRS TO ROOF OF PADMANABHAN ENCLAVE, RODRIGUES ENCLAVE, MALHOTRA ENCLAVE AND ASC SUPPLY DEPOT AT AURANGABAD UNDER GE(S) AHMEDNAGAR
2022_MES_505876_1
8860/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹90,000
Yes
9 Mar 2022
4 Feb 2022
5 Mar 2022
4 Feb 2022
4 Mar 2022
18 Feb 2022
4 Feb 2022 - 11 Feb 2022
60 days
Amount
Demolition of brickwork/stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Dismantling asbestos cement sheets in roof (corrugated or semicorrugated) including ridges complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections of 20 mm bore, complete all as specified and as directed.
M&L for plain cement concrete, 1:3:6, type C-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge including anchorage/bed blocks for hold fasts including demolition of existing PCC complete all as specified and as directed.
M&L for brick work with old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per serial item No 8 but except bricks Note : Old bricks obtained from item No 1 shall be reused.
M&L for rolled mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections conforming to Fe 410-W(Gde-E250) quality A) including distance pieces, cleats etc. all as specified and as directed.
M&L for mild steel work in tubular pipe as in post , purlins, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 all as specified and as directed.
M&L for plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed.
M&L for mild steel flat iron for wind ties in roof sheeting including securing bolts, drilling holes all as specified & as directed.
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 5 to 10mm all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 12mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over one coat of chalk whiting complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over & including a coat of cement wash complete all as specified and as directed.
S&F 8mm thick PVC board, Ist quality, size 600mm x 600mm with and including galvanised iron frame work for seamless ceiling, comprising of galvanised iron perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to center/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm center to center with and including hanger wire, 4 mm dia, galvanised iron upto 1200 mm length adjustable level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and steel expansion fasteners with and including ceilling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to center frame work for false ceiling including dismantling of existing old false ceiling all as specified and as directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by GE, having tensile strength of 550 Mpa as in roof covering/ridges/valley gutters/cladding to wall, fixed with self tapping screws as specified, coloure and design as approved by GE
M&L for 6mm thick asbestos cement , corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed.
All as per serial item No 22 but except sheets all as specified and as directed.
M&L for 6mm thick asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts complete all as specified and as directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaing out and filling solidly with a hot mixture of bitumen and clean dry sand in ratio 1:1 (by weight) all as specified and as directed.
M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:- (i) Taking out old roof treatment including levelling concrete/plaster if any and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 500 mtr distance from starting point as directed. (ii) M&L for 25 mm (average) thick PCC 1:2:4, type B-0, using 12.5 mm graded stone aggregates as levelling course on roof surfaces, mixed with water proofing compound as per manufacturer's instructions, laid to required slope including finishing the concrete surface smooth for laying water proofing treatment. (iii) Cleaning of roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compount will be measured & paid seperatly.
Supply only integral water proofing compound, ISI mark all as specified and as directed.
M & L for preparing surfaces thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles and fill fine crack up to 1 mm with Dr.Fixit roofseal top coat directly by brush or roller after cleaning the cracks stir well prior to application. all joints/corners/drainage outlets and penetration points shall be treated prior to all application of two coat of Dr.Fixit Roofseal Top Coat. all corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating reinforcing fabric. Dr.Fixit Roof Seal Coat may be applied by roller,brush. Apply a coat of Dr.Fixit Roof Seal Coat (diluted with water in ratio 2:1) as self priming 9-10 Sq.mtr/Litre. Allow coating to dry for 3-4 hours prior to applying first coat and second coat. Apply two coats of Dr.Fixit Roof Seal Coat @ 2 -2.2 Sq mtr /litre/coat, without water dilution,the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total DFT of 450=500 micron. Allow the system to air cure for 3 days minimum all as specified and as directed.
Disconnecting existing water tank, exc 250 ltrs but n.exc 500 ltrs capacity, setting aside (or lowering if required) for other repair work, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position all as specified and as directed.
S&F 15mm bore steel water tubes, medium grade, galvanized with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old steel tubing 15mm bore, with and including new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, including taking down old rain water pipes complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed.
M/s S.R lahoti
M/S SHOURYA ENGINEERS AND CONTRACTORS
M/S Tirupati Goroba Shendge
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .