Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC H NO 3 1 197 P58 MYTINAGAR COLONY LB NAGAR HYDERABAD 500 074 | HYDERABAD | HYDERABAD | TELANGANA | 500074 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹12.7 L+₹16,393.95 (1.31%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹12.9 L+₹37,831.85 (3.03%)Rejected-Finance | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹13.3 L+₹81,478.62 (6.52%)Rejected-Finance | L4 | Rejected-Finance Other than L1 bidder | |
| 5 | L5₹13.8 L+₹1.3 L (10.3%)Rejected-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L5 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L6 | Srinivasa Consructions L2 | MS ENTERPRISES L4 | POWER CONSTRUCTION COMPANY L7 | veerender constructions L1 | DPS sales and services india L5 | Srinivash Engineers L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed | 127.98 | Cum | 189 ₹24,188.22 Lowest | 280 ₹35,834.4 | 367 ₹46,968.66 | 270 ₹34,554.6 | 225 ₹28,795.5 | 400 ₹51,192 | 230 ₹29,435.4 |
| 2.00 | Excavation in trenches not exc. 1.5M wide and exc.1.5M & upto 3.0M tin depth for foundation of stay/ pole and etc and getting out in hard/dense soil complete all as specified and as directed | 2.43 | Cum | 360 ₹874.8 | 320 ₹777.6 | 497 ₹1,207.71 | 280 ₹680.4 Lowest | 630 ₹1,530.9 | 450 ₹1,093.5 | 300 ₹729 |
| 3.00 | Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed | 85.05 | Cum | 63 ₹5,358.15 | 40 ₹3,402 Lowest | 157 ₹13,352.85 | 45 ₹3,827.25 | 45 ₹3,827.25 | 150 ₹12,757.5 | 45 ₹3,827.25 |
| 4.00 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed | 36.45 | Cum | 63 ₹2,296.35 | 50 ₹1,822.5 Lowest | 227 ₹8,274.15 | 90 ₹3,280.5 | 72 ₹2,624.4 | 110 ₹4,009.5 | 55 ₹2,004.75 |
| 5.00 | M&L filling sand / Stone dust in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down complete all as specified and directed.
Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment. | 24.3 | Cum | 900 ₹21,870 | 650 ₹15,795 | 637 ₹15,479.1 | 1,350 ₹32,805 | 720 ₹17,496 | 1,800 ₹43,740 | 450 ₹10,935 Lowest |
| 6.00 | M&L in repairs for laying un-reinforced precast concrete cable cover, class HV , type 1 with , size 300 mmX180mmX 40mm complete all as directed | 1,250 | Each | 27 ₹33,750 | 22 ₹27,500 | 21 ₹26,250 | 33 ₹41,250 | 18 ₹22,500 Lowest | 25 ₹31,250 | 18 ₹22,500 Lowest |
| 7.00 | M/L in repairs for cement concrete in foundation (1:4:8) type D2 using 40 mm graded broken stone aggregate for base of foundation complete as specified | 0.81 | CUM | 3,600 ₹2,916 | 3,500 ₹2,835 | 3,677 ₹2,978.37 | 5,000 ₹4,050 | 2,700 ₹2,187 Lowest | 2,800 ₹2,268 | 3,200 ₹2,592 |
| 8.00 | M/L in repairs for cement concrete in foundation (1:3:6) type C2 using 40 mm graded broken stone aggregate including form work complete as specified | 4.51 | CUM | 3,330 ₹15,018.3 | 4,000 ₹18,040 | 3,877 ₹17,485.27 | 5,100 ₹23,001 | 3,600 ₹16,236 | 3,000 ₹13,530 Lowest | 3,200 ₹14,432 |
| 9.00 | M/L in repairs for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed. | 0.78 | Cum | 4,500 ₹3,510 | 4,500 ₹3,510 | 4,027 ₹3,141.06 | 5,400 ₹4,212 | 4,500 ₹3,510 | 2,500 ₹1,950 Lowest | 3,300 ₹2,574 |
| 10.00 | Supply, lay in replacement of GI tubing 100 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed | 6 | RM | 630 ₹3,780 | 800 ₹4,800 | 663 ₹3,978 | 500 ₹3,000 | 495 ₹2,970 Lowest | 850 ₹5,100 | 500 ₹3,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Oct 2025, 6:00 pmClosed
CWE (Army) Secunderabad
Commander Works Engineers Mudfort, MES Office Complex Secunderabad-500 003
REPAIR/MAINTENANCE OF HT DISTRIBUTION SYSTEM INCLUDING REPAIRS TO TRANSFORMERS, GODS LAS EARTHING AND ALLIED WORKS AT CDA, DAD, PAO (OR) AOC, PAO (OR) EME, RUDRAMA GUEST HOUSE UNDER AGE EM NO-II OF GE (UTILITY) SECUNDERABAD.
2025_MES_731947_1
86297
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
7 documents required · 7 mandatory
₹500
GE (UTILITY) Secunderabad
₹40,000
Yes
10 Dec 2025
20 Sept 2025
25 Oct 2025
20 Sept 2025
18 Oct 2025
11 Oct 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed
Excavation in trenches not exc. 1.5M wide and exc.1.5M & upto 3.0M tin depth for foundation of stay/ pole and etc and getting out in hard/dense soil complete all as specified and as directed
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed
M&L filling sand / Stone dust in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
M&L in repairs for laying un-reinforced precast concrete cable cover, class HV , type 1 with , size 300 mmX180mmX 40mm complete all as directed
M/L in repairs for cement concrete in foundation (1:4:8) type D2 using 40 mm graded broken stone aggregate for base of foundation complete as specified
M/L in repairs for cement concrete in foundation (1:3:6) type C2 using 40 mm graded broken stone aggregate including form work complete as specified
M/L in repairs for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed.
Supply, lay in replacement of GI tubing 100 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed
Supply, lay in replacement of GI tubing 80 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed
M&L for boring of horizontally holes under the road below 1.0 mtr from the road/hard surface by trenchless techonology using ultra sound technique and inclduing necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50m from the site of work including supply & laying HDPE pipe up to 150 mm dia suitable for 0.4 MPA work pressure. NOTE: AVERAGE WIDTH OF THE ROAD IS 20 RM. Necessary permissions required from state Govt and other Civil bodies for doing the job is the responsibility of contractor.
Supply, laying, testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core in trenches / pole/ ducts complete all as specified and directed. Note :- Earth work, sand cushioning and cable cover / bricks will be measured and paid for saperately under relevant item of Sch.
M&L for Supply, test, erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-55,11 mtrs HT poles complete all as directed . Note:-(i) Crane charges for erection shall be deemed to be including in quoted rate. (ii) Earth work,PCC,coping shall be measured and paid separately. (iii) The rates include staying the poles in a truely vertical position till the foundations are properly set. (iv)The rates include cast iron base plate,nuts,bolts,screws,painting of steel tubular poles,drilling of holes in steel tubular poles for fixing of clamps,hooks for continuous earth wire/strip.
M&L for Cable jointing kit for 11 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking out old u/s one complete all as directed
M&L for Cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking out old u/s one complete all as directed
M&L for Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking out old u/s one complete all as directed
Supply & Fixing in replacement of Disc insulator single disc 11 KV grade porcelain vitreous brown or green 145mm high and 255 mm dia incl taking down complete all as directed.
Supply & Fixing in replacement pin type insulator 11 KV grade porcelain vitreous brown or green insulator including one galvanised iron washer and one nut 150mm high and 150 mm dia including taking out old unserviceable one complete all as directed
Supply & Fixing in replacement of post top porcelain insulator vitrous brown with GI clamp nuts bolts etc suitable for 11000 Volts grade working pressure incl taking down old unsv one after disconnecting of electric supply connections and restore the supply complete all as directed .
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed.
Dismantling and taking out old UNSV GI Strip and Supply,fix earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm complete with S&F of suitable fixing arrangement, nuts, bolts and washers etc all as specified and directed.
Supply, test, install & commissioning of HT 11 KV outdoor type gang operated air break switch triple pole mechanically operated suitable for horizontal or vertical mounting(suitable for existing one) on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps and connecting up with jumpers, testing and commissioning including dismantling/disconnecting & taking down the old unserviceable one complete all as directed
Dismantling and taking out old UNSV stay assembly and M&L stay assembly comprising of MS stay plate 6 mm thick and of size 300 x 300 mm and 20 mm dia MS stay rod, 2150 mm long including thimbles GI stay strand 7/3.15 mm dia of required length complete all as shown on electrical plate No.1 on page No.495 of MES SSR Part-I 2009 including necessary excavation PCC 1:3:6 Type C2 (using 40mm graded stone aggregate), loop insulator as specified in SSR and including taking down old unserviceable one complete all as directed.
Dismantling and taking out old UNSV lightening arrestor and Supplying, fixing, connecting and testing in repair , single pole zinc oxide (gap less surge type), heavy duty, station class, self supporting outdoor type lighting arresters having rated voltage 09 KV (RMS), discharge current 10 KA insulation level 28/75 KV/KVp (peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of zinc oxide in dermetically sealed container, complete, with metal base, base insulator and suitable terminals for ground connections and pressure relieving arrangement, fixing with suitable nuts, bolts and washers etc complete all as specified and directed
M&L of cross arms i.e bracing supporting clamps back plates, nuts, bolts and washers complete including one under coat and one finishing coat with synthetic enamel paint over a coat of red oxide primer & including taking down old unserviceable complete all as directed
M&L ACSR jumpers in HT/LT over head line upto 10 mm dia as that of existing size including binding wire, nuts & bolts washers complete all as directed
Dismantling and taking out old UNSV danger notice board and M&L of danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white, with letters, figures and convention skull and bones in signal red colour and S&F with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and conforming to IS : 2551-1982
Supply and fixing Tinned Copper fuse wire of 16SWG to 22 SWG or 10 Amps to 100 Amps capacity suitable for 11kV supply specified and directed.
M&L for ACSR conductor, steel reinforced for LT / ht over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
M&L for Disconnection of all Primary/Secondary connections of the defective transformer rating up to 315 kVA out door / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and test, install & commissioning in its original existing position by making all neccessary connections complete all as directed
M&L for Opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body,remove the sludge from tank complete and segregation of HT/LT coil from transformer including job assembling of jointing the connections pf HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber of respective transformer capacity for remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket ( Bushing and tank) etc and welding if any leakage found in body or fins, making good dificient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint aftre cleaning inside transformer tanks and two coats of outside painting including writing KVA Capacity, repairs of body by means of welding, jointing if required complete for capacity up to 315 KVA with complete Testing and Commissioning all as directed
M&L in repairs for Making Primery/secondary coil with High conductivity Electrolytic copper wire of required gauge as per specification of old existing transformer including making of coil as required of various capacity of transformer complete all as directed
M&L for Reconditioning of over heated HT/ LT coil of transformer up to 315 KVA after removing all old insulation any type and re-insulation with insulated craft paper cotton tape Class 'F' insulation as required complete all as directed
M&L for Opening of the 11 KV / 0.433 KV Distribution transformer rating up to 315 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level,check leaked cork seal(if any), check the un sericeable insulators & LT/HT bush (if any) complete from the shell and making connections of LT/HT bush,insulators & cork seals to avoid leakage and refilling oil back to existing postion into the transformer complete testing & commissioning complete all as directed . Note: Spares shall be measured and paid separately under relevant items. Necessary arrangement for repairs on timely basis at site to be made by contractor and minor items like cork seal, insulators, bolts, nuts and washers required for arresting leakages are deemed to be included in the quoted rates.
S&F in renewal of transformer bushing LT side including brass set stems conical bush/gasket for indoor/outdoor transformer upto 315 KVA :- Note : The rates quoted is deemed to be included the cost of necessary labour charges for draining out transforer oil, opening of top cover by unscrewing nut, bolts washers and and suitable size pad type bus bar almuminium and nut pach washers etc
S&F following accessories of transformer in replacement of unserviceable, complete all as directed :-
Top cover gasket and gaskets set fo conservator tank etc complete of FOR DISTRIBUTION TRANSFORMER OF 50-315 KVA any capacity as per site requirement.
Temp gauge 0-100 degree Celcius suitable for distribution transformer 11/0. 433 KV with stem 6'' guage
Porcelain transformer bushing HT 11 KV including brass set stems, conical bush/ gasket for indoor/outdoor transformer upto 315 KVA as per IS-3347 complete all as specified and as directed.
LT rod / studs for any make of transformer rating up to 315 KVA mounted on pole/plinth, made of brass with nut, cup and washers and fittings etc as per size and shape of original complete including taking down old u/s one complete all as directed
S&F in renewal silca jel breather assembly with vent pipe for indoor/outdoor transformer of 63 to 315 KVA of size 250g capacity including silicagel complete all as directed.
Supply and filling in replacement of transformer oil as per IS :335 with 70KV di-electric strength complete in transformer plinth / pole mounted including testing insulation and vescocity of oil all as specified and directed .
M&L for Dehydration including filtration cleaning of transformer oil , testing of di-electric strength of transformer oil of indoor/Outdoor type transformer 11KV/433 volt. Filtration of transformer Oil by passing through filtration Machine/Plant to remove moisture , impurities and for improving di-electric strength to above 70 Kv for 2mm gap and machine having minimum Capacity 1000 to 30000 Ltr/hrs. Testing of insulation and vescocity of Oil before and after dehydration to be carried out site. Note to be added : Contractor Carryout the filtration at site by on line machine with giving printouts of di-electric strength shall cost quoted in unit rate only.
Arresting leakage of transformer fins by replacing fins etc, after removing of oil from inside of transformer and refilling of oil by opening top cover of transformer of capacity upto 315KVA
M&L for cleaning/Painting of 4 pole structure /2 Pole structure/single Pole structure of any type/size/length and removing existing painting by using wire brush using with emery paper and cleaning with chemical agents, after cleaning the poles two coats of red oxide primer and two coats of synthetic aluminium painting satisfactorily by Engr-in'Charge and Painting work carryout at any height and including marking of pole numbers as directed and safety eqpts & tools will be own arrangement and marking and colour washing of pole coping all as specified and directed of the following.
Two poles with cross Arms
Four Poles with cross Arms
Single HT 11mtr Pole with cross Arms
Inspection of defective 11kv HT cable(laid in UG/trench/tunnel/wall/surface) to locate the fault using cable fault Locator machine(by surge generators mounted on Van) (fault either by Short/Moisture/earth fault or any type) including complete all as directed.
Inspection of defective LT cable (laid in UG/trench/tunnel/wall/surface) to locate the fault using cable fault Locator machine(by surge generators mounted on Van) (fault either by Short/Moisture/earth fault or any type) including complete all as directed.
M&L for Spray painting of upto 500 KVA transformer pole mounted / plinth mounted at site and applying two coat of synthetic enameled Smoke grey paint after removing all dust & rust and paint including marking or transformer capacity with stencil letter with black or white paint and Font and Size of letter shall, complete all as specified and directed
Taking out and Relaying of HT 11 KV cable of size 95 sq mm to 150 Sqmm 3 core after carrying out necessary Repair such as joining with Suitable joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: (a) Earth work , sand Cushioning, brick protection, Joints shall be measured and paid separately under Relevent Item) (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item)
Relaying of serviceable bricks / pcc cover of any size retrived during taking out of HT cable complete all as directed
Cutting anxious green growth / vegetation growth for cleaning out the area around transformer installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm complete.
Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on HT/LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed.
Cutting the existing road straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. Note: Necessary work permissions for the works to be carried in Civil/Public ares/Defence areas to be taken by the contractor prior to starting the work. Laision with concerned departments is the responsibility of contractor. Department will do the necessary authorised correspondence for the said approvals. No extra payment will be entertained on this account.
Surface excavation in hard/dence soil n.exc (not exceeding) 30 cm deep and averaging 30cm deep and getting out complete alla s specified and as directed
M&L coarse aggregate 40mm graded deposited, spread and levelled complete all as specified and as directed for tranformer yard.
M&L Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Srinivasa Consructions (BID ID -3452040)
Srinivash Engineers (BID ID -3449438)
MS ENTERPRISES (BID ID -3456592)
DPS sales and services india (BID ID -3454376)
L and S ENTERPRISES (BID ID -3449192)
POWER CONSTRUCTION COMPANY (BID ID -3459419)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tender86297.pdf
Tender Documents • 1.03 MB
BOQ_819483.xls
BOQ • 0.94 MB
86297corrige03Oct.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .