Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹26.8 L+₹6.0 L (29.0%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.8 L+₹8.1 L (38.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹29.3 L+₹8.6 L (41.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹29.5 L+₹8.8 L (42.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹28.6 L
EMD Value
₹57,200
Closing Date
14 Dec 2022, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
SPECIAL REPAIR / REPLACEMENT OF STREET LIGHTS AND SOLAR LIGHTS OF IN JETTY AT NAVAL WHARF AREA -NSRY AND OTHER MINOR WORKS AT COAST GUARD AND NSRY UNDER AGE E/M AT GE HADDO, PORT BLAIR
2022_MES_563535_1
8693/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and Category b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹57,200
Yes
6 Jan 2023
16 Nov 2022
21 Dec 2022
16 Nov 2022
14 Dec 2022
2 Dec 2022
17 Nov 2022 - 24 Nov 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in soft/loose soil; for foundation of poles or cable laying complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC type C1 (1:3:6) (using 20 mm graded stone aggregate) as in foundation of poles / stay assembly complete all as specified and as directed.
M&L for pre cast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including use and waste of form work complete all as specified and directed
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 10 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material and including taking down old u/s cable complete all as specified and as directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engg-in-Charge before the cable is laid. (ii)Excavation earth work will be measured and paid separately Make : Gloster / Havells / Anchor / Polycab / Finolex.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 25Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engg-in-Charge before the cable is laid. (ii)Excavation earth work will be measured and paid separately Make : Gloster / Havells / Anchor / Polycab / Finolex.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make : REX POLYEXTRUSION LTD/ Tirupati plastomatics Pvt Ltd
S&F FRP pole box of size 170x170x105mm consisting of 50 Amps, 4 pole connector - 1 No. and MCB, SP, 16 Amps, 10 KA - 1 No. with necessary clamps, bolts, nuts and washers including taking down old unserviceable one complete all as specified and as directed. MAKE of FRP Box: Hansel/ SINTEX Cat No. GS-JB-1414 MAKE of MCB: L&T/ HAVELLS/ LEGRAND
S&F timer, heavy duty, 110- 230 Volts, 50Hz with built in sealed rechargeable maintenance free battery 16 Amps, 12 AH capacity having backup of 100 hours, weekly programmable including taking down the old unserviceable timer complete all as specified and as directed. MAKE: INDO ASIAN Cat Part No. TA926453 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F contactor, 3 pole, 415 Volts, 40 Amps, ML-2, 2 NO+NC, heavy duty including taking down the old unserviceable contactor complete all as specified and as directed. MAKE: L&T Cat Part No. SS90701 or equivalent in HAVELLS or INDO ASIAN (Cat Part No. 850533)
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 70 Watts capacity, 8400 luminaire, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary brackets of suitable size, bolts, nuts and washers as required fixing on high mast of 16 mtr of power factor >0.9 and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable any type of light fitting complete all as specified and as directed. MAKE: PHILIPS Cart part No.BVP182 LED70 CW/NW/WW or equivalent in CROMPTON GREAVES/ HAVELLS
S&F LED street light fittings of high power LED, IP 66 protection and unique power lens to ensure uniform light distribution with LED of 70 Watts capacity, 8400 luminaire, 220 V, 50 Hz including necessary brackets of suitable size, bolts, nuts and washers as required and including taking down old unserviceable halogen / any type of light fittings complete all as specified and as directed. MAKE: PHILIPS Cart part No.BRP062 LED 84 CW SLC S1 PSU or equivalent model of CROMPTON GREAVES/ HAVELLS
S&F LED Bollard with round top 10 Watts, 220V, 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation, 3 core 2.5 Sqmm multistranded copper conductor drawn through and including 25mm dia rigid PVC conduit from one light to other (approx distance 30 metres) with cable connectors including taking down old unserviceable one complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LBLSN-10-CDL or equivalent in BAJAJ/ HAVELLS/ PHILIPS 58167 YOB PEDESTAl/C&S Cat Part No. Canis 10W
S&F LED post top luminaire, outdoor type (Prince opera midi) of 240 Volts, 50Hz, 40 watt capacity, IP 65 protection including mounting on 63mm dia galvanised medium grade pipe of 2.0 metre height from GL with necessary PCC (1:2:4) type B1 foundation and connecting up with and including 3 core 2.5 Sq mm multistranded copper conductor cable drawn through 25 mm dia rigid PVC conduit from one light to other (Approx distance between two posts 30 metres) including taking down old unserviceable one complete all as specified and as directed. MAKE:CROMPTON GREAVES Cat part No. LPTO-40-CDL or equivalent in PHILIPS/ C&S Cat Part No. LTGLC40WHPLED/W
M&L for steel tubular swaged poles 410 SP-31 (9.0 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed. MAKE : Kalinga Tubes/ The national Tubes Co/ India Tube & Co.
S&F MCCB, 4 pole, 125 Amps, 50Hz, 25kA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCB, SPN, "C" series, 240 volts, 40 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCB, TPN, "C" series, 240 volts, 63 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
M&L for 40mm dia or bore galvanised steel tubing, light grade, with all fittings and fixed to walls/poles or laid in floors complete as in protection of cables incl taking down old u/s GI pipe complete all as specified and as directed. MAKE : TATAT/ Jindal/ Surya / Prakash/ Bansal
M&L for street light mounting bracket made up of 40mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer including taking down old u/s brackets complete all as specified and directed.
S&F solar light street fitting of 175 lumen / watt having highly safe & advanced long life, maintenance free lithium ferro phosphate (LiRePO) battery & highly efficient microcontroller with driver and luminaire, having two days battery backup with factory setting dimmer profile, PIR sensor with properly DC connection including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cat Part No. BRP710 LED30 CW MR S1 12V LFP AIO Solar Equip IN 17W, 3000 Lumen/CG/ HAVELLS/C&S
S&F outdoor type street light timer panel/ Distribution board with 110A, 3 pole, 230 Volts contactor and Digital 24Hrs Anolog time switch, 125A MCCB, Manual and Auto Mode Toggle switch cable connectors all as specified and as directed. Make: IndoAsian Time Lite Cat No : TL065DB0/ Havells Cat No IHXTS09120/ L&T/ Legrand.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to GI strip of 25 x 4mm as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Supply, installation, commisioning of Water Cooler partially stainless steel, electric driven, single phase having approx storage and nominal cooling capacity as 40/80 Ltrs complete all as specified & directed.
Supply and laying of CPVC pipe of size 20mm, SDR 11 & plain CPVC SDR 11 including all fittings such as Tees/Bends/Sockets/Unions/Ball valves on walls/ Ceiling or laying in floors complete all as specified.
M&L for Point wiring complete with two 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board. Make of wire : Polycab / Gloster / Anchor / Havells / Finolex / Anchor Make of PVC Casing & Caping : Modi / Precision / Supreme / Finolex / Polycab
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
S&F socket outlet, 2-in-1, 3 pin, 5/15A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make : Anchor / Cona / Legrand
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma fileter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and direceted. NOTE : All connected pipes must be covered by insulation material. The drain out water pipe connection should be connected upto ground level. MAKE : LG/Whirl Pool/ Hitachi/ Blue Star.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma fileter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 TR complete all as specified and direceted. NOTE : All connected pipes must be covered by insulation material. The drain out water pipe connection should be connected upto ground level. MAKE : LG/Whirl Pool/ Hitachi/ Blue Star.
S&F Electronic voltage stablizer of 4 KVA capacity, wall mounting (Automatic Operation) type having features such as Intelligent time delay system of 2 to 4 minutes, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations, thermal over load protection, wide input variation between 170 Volts to 250 Volts with output voltage stablized at 230 Volts, with accuracy of +2.5% suitable for split type airconditioner complete all as specified and as directed. MAKE: V-GUARD / PREMIER
S&F Electronic voltage stablizer of 5 KVA capacity, wall mounting (Automatic Operation) type having features such as Intelligent time delay system of 2 to 4 minutes, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations, thermal over load protection, wide input variation between 170 Volts to 250 Volts with output voltage stablized at 230 Volts, with accuracy of +2.5% suitable for split type airconditioner complete all as specified and as directed. MAKE: V-GUARD / PREMIER
BHARAT MULTITECH INDUSTRIES PVT LTD
JKS CONSTRUCTION
M/s K Moorthi
ISLAND SALES ENTERPRISES
CHANDER SEKER ENTERPRISE
SKV Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .