Loading…
Loading…
Tender Value
₹14.6 L
EMD Value
₹29,200
Closing Date
13 Feb 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
GENERAL
27 conditions · 5 needing a document upload
Documents to be uploaded only in the website by the Tenderer Following Annexures duly filled and signed are to be uploaded online only prior to Closing of Tender. Original copy of all the documents to be submitted to office within 7 days whenever demanded by the Railway. Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/tenderers. Annexures are available at Upload/View Document menu in Home Page of IREPS portal for works tender.
The details of the works completed by the tenderer during the last three years to be filled in Annexure-I(a) & Details of contractual payment received by the Tenderer during the last 3 (three) financial years including the current financial year to be filled & submitted in Annexure-I(b).
The details of Plants and Machinery with the tenderer to be filled in Annexure- II.
Details of Personnel and Organization of the Tenderer to be filled in Annexure-III.
Details of Works presently on hand of the Tenderer to be filled in Annexure- IV.
The details regarding Association of Railway Officer s with the tenderer to be filled in Annexure- V.
List of the Arbitration cases of the Tenderer during last Five years to be filled in Annexure-VI.
List of the Court cases of the Tenderer during last Five years to be filled in Annexure- VII.
NEFT MANDATE FORM. All Payments to the agency including the refund of the Earnest Money of the unsuccessful bidder preferably will be remitted through NEFT. The Tenderer is required to submit Bank details and A/C No. etc. in Annexure- VIII.
Documents to be uploaded in the website by the Tenderer : Online payments have been made and no documents are to be deposited.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer shall upload scanned copy of valid PAN and GSTIN in PDF format.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII and VIII respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/tenderer's.
Annexure:- IV, V , VI, VII and VIII.
Asansol Division - Provision of new OFC Room in ASN DIVN.
EL-48-25~ER
EL-48-25
Open
Works - General
12 Months
Paschim Bardhaman, West Bengal
₹0
₹29,200
13 Feb 2026
21 Jan 2026
30 Jan 2026
57 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 14,60,152.38 | ||
| — | 90.00 | — | — | ||
| Price for supply of indoor T8(1x18w) / T8(1x20w)tube light fitting complete with all accessories and LED batten including built -in-driver. | — | — | — | 24,409.8 | |
| — | 90.00 | — | — | ||
| Price for erection, testing, electrical connection and commissioning of indoor LED T8(1x18W)/ T8(1x20w) fitting along with lamp. | — | — | — | 6,771.6 | |
| — | 18.00 | — | — | ||
| Price for supply of High efficiency BLDC fan with electronic regulator,(without remote),having sweep size1200MM, operating voltage 140V-270V maximum power consumption 26 watt(+/- 10%) with double ball bearing and airflow CMM210, white colour. | — | — | — | 47,430 | |
| — | 18.00 | — | — | ||
| Price for supply of polycarbonate penta step modular type fan regulator(white). | — | — | — | 4,702.5 | |
| — | 18.00 | — | — | ||
| Price for fixing charges of BLDC Fan & Regulator. | — | — | — | 958.5 | |
| — | 18.00 | — | — | ||
| Price for supply of single phase propeller type ventilating fans(Exhaust Fans) number of pole :4, sweep size(mm):300. | — | — | — | 36,000 | |
| — | 18.00 | — | — | ||
| Price for fixing charges of Exhaust Fan. | — | — | — | 4,323.96 | |
| — | 146.00 | — | — | ||
| Price for supply of wiring materials & PVC conduit/concealed wiring charges of Light point / Fan point/Ex. Fan point. | — | — | — | 61,150.64 | |
| — | 36.00 | — | — | ||
| Price for supply of wiring material & concealed / PVC conduit wiring charges for 5 Amps plug point with modular switch. | — | — | — | 10,790.28 | |
| — | 36.00 | — | — | ||
| Price for supply of wiring material & concealed/PVC conduit wiring charges for 15 Amps plug point with modular switch | — | — | — | 20,039.76 | |
| — | 2423.00 | — | — | ||
| price for Cable trenching laying & back filling electrical connection as per IS-1255, 1983 or latest. | — | — | — | 5,18,182.78 | |
| — | 375.00 | — | — | ||
| Price for Cable laying through wall/floor by groove cutting. | — | — | — | 23,122.5 | |
| — | 375.00 | — | — | ||
| Price for Cable laying on wall/Structure by MS/ Clamps nuts & bolts. | — | — | — | 21,045 | |
| — | 300.00 | — | — | ||
| Price for supply of GI pipe 50mm dia, medium gauge & cable laying through GI pipe for Track/road/drain crossing. | — | — | — | 1,11,486 | |
| — | 9.00 | — | — | ||
| Price for supply of 3m long 50 mm dia. medium gauge GI pipe & cable laying through GI pipe for protection. | — | — | — | 11,185.38 | |
| — | 9.00 | — | — | ||
| Price for supply & Fixing of 8 way outdoor type thermoplastic transparent LID , IP65, PC weatherproof Junction box size (300mm x 450mm x 132mm)with 04 nos. 100A capacitor, aluminium ,Busbar. | — | — | — | 2,12,400 | |
| — | 9.00 | — | — | ||
| Price for supply , installation, testing and commissioning of 100A LT outdoor panel location box. | — | — | — | 65,791.98 | |
| — | 300.00 | — | — | ||
| Price for supply of wiring materials & PVC conduit / concealed wiring charges of main wiring. | — | — | — | 31,368 | |
| — | 930.00 | — | — | ||
| Price for supply of wiring materials & PVC conduit / concealed wiring charges of sub main wiring. | — | — | — | 74,790.6 | |
| — | 9.00 | — | — | ||
| Price for supply and fixing of SP MCB DB 4 way along with MCB 6-32A & DP isolator 40A. | — | — | — | 16,633.44 | |
| — | 9.00 | — | — | ||
| Price for supply and fixing 32 A RCBO- A type((SPN-2M) leakage current capacity 30mA.; 240V, 50 Hz with 10 KA short circuit capacity. | — | — | — | 42,336 | |
| — | 9.00 | — | — | ||
| Price for supply & fixing MCB enclosure 2 way sheet steel for RCBO fixing inside the enclosure. | — | — | — | 3,672 | |
| — | 9.00 | — | — | ||
| Price for supply, fixing & connection of LED flood light 100Watt complete. IP66 protection system. | — | — | — | 53,053.83 | |
| — | 9.00 | — | — | ||
| Price for supply of wiring materials & wiring charges of street light point on pole. | — | — | — | 3,487.5 | |
| — | 9.00 | — | — | ||
| Price for supply of main switch 100A,ICTPN, 415V AC 50 Hz. | — | — | — | 16,447.5 | |
| — | 9.00 | — | — | ||
| Price for fixing charge of Main switch 100 A, ICTPN, 415V AC, 50Hz. | — | — | — | 2,914.56 | |
| — | 9.00 | — | — | ||
| Price for supply and fixing of 25A AC starter,16A socket & AC point wiring with 4 sq. mm HTFR muti stand flexible copper PVC wire. | — | — | — | 15,750 | |
| — | 9.00 | — | — | ||
| Price for supply of GI pipe 50mm dia. 3m long med. gauge along with earthing arrangement . | — | — | — | 19,908.27 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .