Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 18 SANKAR BOSE ROAD KOLKATA | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.6 L+₹5,583.86 (0.24%)Rejected-Finance 76 CRIPER ROAD KONNAGAR HOOGHLY | KONNAGAR | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹23.6 L+₹12,539.21 (0.53%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L3 | Rejected-Finance Rejected | |
| 4 | L4₹23.7 L+₹18,543.50 (0.79%)Rejected-Finance 1 1 NORTH ROAD JADAVPUR KOLKATA | KOLKATA | WEST BENGAL | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹55,300
Closing Date
29 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Public Health Engineering Directorate Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Providing and installation of power backup arrangement with allied works at Karakdanga CWR site, for proposed water supply scheme for availability of water 3.8Lac LPD super specialty for BSMC and H in the district of Bankura under BMD, PHED
2022_PHED_419349_3
WBPHED/EE/BMD/NIeT- 19 OF 2022-2023
Open Tender
MECHANICAL
Item Rate
45 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹55,300
Yes
15 Dec 2022
11 Nov 2022
1 Dec 2022
11 Nov 2022
29 Nov 2022
11 Nov 2022
Amount
Supply and delivery of 3 Phase 415Volt,50Hz, 40 KVA Sound proof Air Cooled Weather Proof Green Diesel Generator Set having following specification. a) Alternater- 3phase,415volt, 50Hz, 0.8Pf (Laf) 1500 RPM self exited , selt regulater with Automatic voltage regulater & class H insulation for stator &rotor winding b) Engine- Multi Cylinder, vertical, cold string engine 1500 Rpm 52.4 bhp(Approx) with turbo charge & all essential features like silencer, air cleaner, fuel pump with machanical governor, lube oil cooling with filter, water pump for engine cooling radiator,12 volt electric starting system batery charger, fuel tank of capacity 8hrs operation etc. as per technical specification Make- Kirlosker/Cammins/Ashoke Lelend/Mahindra & Mahindra/Any Approved make. (Test certificate & warranty certificate from manufaturar should be submitted at the time of delivery)
Supply and delivery of following cable
70 Sq. mm. 3.5 Crore 1.1KV Grade PVC insulated AL, Ar Cable.As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. For D.G to PDB to MCC
2.5Sq. mm. 8 Crore 1.1KV Grade PVC insulated Armoured Copper conductor control Cable. As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. For D.G to AMF panel
6Sq. mm. two(2) Crore 1.1KV Grade PVC insulated Unarmoured Copper conductor power Cable. As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. For AMF panel to Battery
Laying 1.1 KVA Grade 70 sq.mm. 3.5 Crore PVC insulated Ar. Aluminium conductor cable in under groung strentch 460mm. Wide X 760mm. Average depth with brick protection on the top of the cable with 8(eight) nos. bricks per meter including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed.
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supply and delivery at site of fabricated cubical type 415Volt wall mounted PDB with hinge type front door cover made of 2 mm thick CRCA sheet and suitable locking arrangement with powder coated paint and degree of protection IP-54 and as per Technical Specification.
Installation of the above D.G set after construction of RCC base size of 5m (L) x 3m (W) and 1m (H) installation of PDB Panel, cable finishing, socketing, caneecting of incomming and outgoing cannection including supplying of all neceseris meterials all complete as per direction of EIC and as per Technical Specification.
Earthing
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil
(a) Earthing with 65 mm dia GI Pipe (TATA-Medium) X 3.0 Mtrs. Long and 1no. 50mm X 6mm galvanized (Hot Dip) steel strip (4mtrs. Long), 20 mm dia X 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65mm dia GI Pipe (ISI-Medium) protection (3mtr. long) to be filled with bitumen partly under the ground level and partly above the ground level to an average depth of 3.65 mtr. (Two set for nuetral earthing & two set for body earthing )
(b) Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm. X 86.36cm. X 46 cm. deep (below ground level ) complete with cemented brick work (1:6) of 25 cm. with duly plastered with cement mortar (inside) C.I. hinged inspection cover of size 36.56 cm. X 35.56 with locking arrangement, G.I. reducer including drilling of 46 nos. 12 mm dia holes on the G.I. pipe
(c) Extra for treatment of soil by using salt and charcol or coke for pipe electrode ( for soft soil )
(d) Connecting the equipments body / Neutral to earth busbar, including S & F 50mm X 6mm Galvanized (Hot Dip) MS flat on wall / floor with GI saddle as required and connection to equipments with including drilling holes, bolts, nuts, washers etc.
Commissioning of above Diesel Generator set ,PDB Pannel and other with engagement of authorised representative of the company upto the entire satisfaction of E.I.C. (Fuel will be supplied by the Agency )
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). a) With 0.5 mm thick sheet
Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary
(a) Depth of excavation not exceeding 1,500 mm.
Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and consolidating same by thorough saturation with water ramming complete including cost of supply of sand.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
a) Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes. i) Pakur variety
Painting of M.S trust by the ready mixed primer of approved make, and brand incl. preparation of surface by sand paper, cleaning etc. for receiving two coat of superior quality synthetic oil bound paint after applying one coat of red lead chromate primer as per direction of EIC
Add: 18% GST
Add: 1% Cess
MAHADEV ENTERPRISE
ORIENTAL ENGINEERING CO.
MACHINE SUPPLIERS SYNDICATE PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .