Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹12 L
Closing Date
7 Jun 2021, 4:00 pmClosed
Exe Eng PHE Mech. Div Jawaharnagar Sgr
Exe Eng PHE Mech. Div Jawaharnagar Sgr
Rate contract for various Electrical works
2021_PHE_125386_1
(JSMDS-NIT No -(E-09 of 05/2021)
Open Tender
Repair and Maintenance Works
Item Rate
2 days
Pokhribal
Please refer Tender documents.
2 documents required · 2 mandatory
₹150
Yes
Exe Eng PHE Mech. Div Jawaharnagar Sgr
Exempted
Exe Eng PHE Mech. Div Jawaharnagar Sgr
24 Jun 2021
28 May 2021
10 Jun 2021
28 May 2021
7 Jun 2021
28 May 2021
2 Jun 2021
a. Disassembling of 3phase, 415±10% V, 120 HP star/delta vertical motor from the V.T Pump, shifting it to workshop for conducting repairs by hiring and loading into the load carrier and then back to the site of work by load carrier. The job further includes mounting back motor on the V.T Pump. The job further includes cost on account of skilled /semi skilled labour tools and tackles required for the work and testing of motor on full load. (The rate per job shall be allowed @ 5.4% of the quoted / negotiated rate of whole item.) b. Complete rewinding of 120 HP, 1465 RPM, 3 phase, Star/delta vertical Motor using copper winding of suitable size, grade, gauge number of turns at water supply scheme Pokhribal stage –1st. the complete details of work are as under: i. Disassembling of motor at the work shop by way of removing the, the Rotor, checking and cleaning the rotor. The job includes removing the damaged/ burnt out windings from the slots and cleaning the slots. (The rate per job shall be allowed @ 4.63% of the quoted / Negotiated rate of whole item) ii. Copper winding used in rewinding of motor. The rate includes the rebate on old scrap (The rate per kg shall be allowed @ 0.69% of the quoted/ negotiated rate of whole item.) iii. Rewinding of motor by way of employing highly skilled labour, tools, tackles etc. (The rate per kg shall be allowed @ .46% of the quoted / Negotiated rate of whole item .) iv. Cost on account of providing and fitting of insulating material such as PVC sleeves, bamboo sticks etc.( Rate charges should be as per, Per Kilogram of copper wire) (The rate per kg shall be allowed @.08 % of the quoted/ Negotiated rate of whole item) v. Re-assembling of motor by way of fitting rotor without causing damages to stator coils, checking the motor . (The rate per job shall be allowed @ 3.09% of the quoted / negotiated rate of whole item.) vi. Providing and fitting of 6316 ball bearing to be fitted from the NDE of motor (The rate per job shall be allowed @ 12.35% of the quoted / Negotiated rate of whole item) vii. Providing and fitting of 7322 antifriction bearing to be fitted from the DE of motor (The rate per job shall be allowed @ 73.30% of the quoted / Negotiated rate of whole item.)
Disassembling of 120 HP, 3 phase , 415 ±15 % Volt star- delta starter from the circuitry and shifting it from the site to work shop and back to site after conducting due repairs by loading it into load carrier. The job further includes refitting back the starter into the circuitry. The job further includes cost on account of skilled/semi-skilled labour, tools and tackles required for the job and testing of starter on full load.
Removing of damaged ML-10 Power contactor assembly and providing, fitting and testing of power contactor assembly to be fitted to 120 HP starter at WSS Pokhribal stage –1st. The complete specification of the power contactor assembly is as under. Type = ML-10 Make = L&T or equivalent VOLTAGE = 415 ± 15% V Frequency = 50 ± 3% Hz No. of poles = 3 Besides the above specifications, the 3 pole ML- 10 power contactor assembly Should conform to IS/IEC 60947-4-1 and IEC 60947-4-1. The job further includes testing of power contactor assembly at Full load.
Removing of damaged ML-06 Power contactor assembly and Providing, fitting and testing of star power contactor assembly to be fitted to 120 HP starter at wss Pokhribal stage –ist The complete specification of the power contactor assembly is as under. Type = ML-06 Make = L&T or equivalent VOLTAGE = 415 ± 15% V Frequency = 50 ± 3% Hz No. of poles = 3 Besides the above specifications, the 3 pole ML- 10 power contactor assembly Should conform to IS/IEC 60947-4-1 and IEC 60947-4-1. The job further includes testing of power contactor assembly at Full load.
Removing of damaged ML-10 power Contactor spare contact kit from the 120 HP starter . the job further includes Providing and fitting of new ML-10 power Contactor spare contact set of L&T or equivalent Make.
Removing of damaged ML-6 power Contactor spare contact kit from the 120 HP starter . the job further includes Providing and fitting of new ML-6 power Contactor spare contact set of L&T or equivalent Make.
Removing of damaged electronic timer assembly from the 120 HP starter and P/F of new Timer assembly having time setting 0.05 sec. min. and 60 sec. max. to be fitted to 120 HP starter
Removing of damaged ML-6 contactor coil from the 120 HP starter. The job further includes Providing and fitting of new ML-6 contactor coil of L&T or equivalent Make.
Removing of damaged ML-10 contactor coil from the 120 HP starter. The job further includes Providing and fitting of new ML-10 contactor coil of L&T or equivalent Make.
Removing of damaged C.T Operated thermal over load relay from 120 HP starters. The job further includes Providing and fitting of new C.T Operated thermal overload relay having relay range 90-140 A of L&T or equivalent Make.
Removing of damaged C.T coil and P/F of new C.T coil having ratio 400/5 A , VA : 15 of reputed make
Removing of damaged single phase preventer and P/F new single Phase preventer to be fitted to 120 HP star/delta starter.
Removing of damaged motor protection under volt relay with inbuilt timer and P/F new motor protection under volt relay with inbuilt timer to be fitted to 120 HP star/delta starter
Removing of damaged 1.5 sq.mm single core , single stranded PVC Copper wire and P/F of new 1.5 sq.mm single core , single stranded PVC Copper wire to be fitted to 120 HP motor starter
Removing of damaged 2.5 sq.mm single core , single stranded PVC Copper wire and P/F of new 2.5 sq.mm single core , single stranded PVC Copper wire to be fitted to 120 HP motor starter
i. Disassembling of 200 KVA , 3 phase , 415 ±15 % Volt manually operated oil cooled voltage stabilizer from the circuitry and shifting it from the site to work shop and back to site after conducting due repairs by loading it into the load carrier . The job further includes refitting back the voltage stabilizer into the circuitry. The job further includes cost on account of skilled/semi- skilled labour, tools and tackles required for the job and testing of Voltage stabilizer on full load. (The rate per job shall be allowed @ 8.61% of the quoted / Negotiated rate of whole item .) ii. Disassembling of 200 KVA , 3 phase , 415 ±15 % Volt manually operated oil cooled voltage stabilizer by way of removing all the nuts and bolts and lifting the winding assembly along with core for assessing the damages and and refitting back the winding assembly into the voltage stabilizer tank along with core after conducting the due repairs . (The rate per job shall be allowed @ 7.65% of the quoted / Negotiated rate of whole item .) iii. Removing of damaged / burnt out windings from 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer leg and rewinding the same using copper winding of appropriate grade, insulation and specifications . the job includes cost on account of skilled/semi-skilled labour required for the winding of Voltage stabilizer leg. The rates are included of the rebate on account of old scrap. (The rate per kg shall be allowed @ 0.86% of the quoted / Negotiated rate of whole item.) iv) Removing of damaged plate type voltage regulator switch from 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. The job includes cost on account of skilled/semi-skilled labour required for work (The rate per job shall be allowed @ 55.5% of the quoted / Negotiated rate of whole item .) v) Removing of damaged plate type voltage regulator switch from 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper contact point -01 no. complete of appropriate specifications to plate type voltage regulator switch having copper contact points with 6 steps. The job includes cost on account of refitting back the voltage regulator switch and skilled/semi-skilled labour required for work. (The rate per job shall be allowed @ 12.44% of the quote/ Negotiated rate of whole item) vi) Impregnation / heat treatment of winding assembly of 200KVA , 3 phase , 415 ±15 % Volt voltage stabilizer by way of keeping it in an electric oven for about 24 hours and at approperate temperature. (The rate per job shall be allowed @ 8.61% of the quoted rate of whole item .) vii )Removing of damaged copper connection terminal bolt with washer and nut from 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer. (The rate per job shall be allowed @ 1.44% of the quoted / Negotiated rate of whole item) viii) Removing of damaged backalite connection plate from 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new backalite connection plate. (The rate per job shall be allowed @ 2.30% of the quoted / Negotiated rate of whole item) ix) Arresting of leakage in 200 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubes by way of soldering/ welding at the cracked spot (average length of spot = 1 cm) (The rate per job shall be allowed @ 2.30% of the quoted / Negotiated rate of whole item) x) Providing and fitting of 53 KA di-electric strength T- OIL of standard make (The rate per ltr shall be allowed @ 0.25% of the quoted / Negotiated rate of whole item) Xi) Filtration of existing T- oil upto desired strength and specifications. (The rate per ltr shall be allowed @ 0.04% of the quoted / Negotiated rate of whole item)
Disassembling of 250 KVA , 3 phase , 415 ±15 % Volt manually operated oil cooled voltage stabilizer from the circuitry and shifting it from the site to work shop and back to site after conducting due repairs by loading it into the load carrier . The job further includes refitting back the voltage stabilizer into the circuitry. The job further includes cost on account of skilled/semi- skilled labour, tools and tackles required for the job and testing of Voltage stabilizer on full load.
Disassembling of 250 KVA , 3 phase , 415 ±15 % Volt manually operated oil cooled voltage stabilizer by way of removing all the nuts and bolts and lifting the winding assembly along with core for assessing the damages and and refitting back the winding assembly into the voltage stabilizer tank along with core after conducting the due repairs .
Removing of damaged / burnt out windings from 250 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer leg and rewinding the same using copper winding of appropriate grade, insulation and specifications . the job includes cost on account of skilled/semi-skilled labour required for the winding of Voltage stabilizer leg The rates are included of the rebate on account of old scrap.
Removing of damaged plate type voltage regulator switch from 250 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps . the job includes cost on account of skilled/semi-skilled labour required for work
Removing of damaged plate type voltage regulator switch from 250 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper contact point -01 no. complete of appropriate specifications to plate type voltage regulator switch having copper contact points with 6 steps . The job includes cost on account of refitting back the voltage regulator switch and skilled/semi-skilled labour required for work.
Impregnation / heat treatment of winding assembly of 250KVA , 3 phase , 415 ±15 % Volt voltage stabilizer by way of keeping it in an electric oven for about 24 hours and at approperate temperature.
Removing of damaged copper connection terminal bolt with washer and nut from 250 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer.
Removing of damaged backlite connection plate from 250 KVA, 3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new backalite connection plate.
Arresting of leakage in 250 KVA , 3 phase , 415 ±15 % Volt voltage stabilizer tank along with radiator fins/tubes by way of soldering/ welding at the cracked spot (average length of spot = 1 cm)
Providing and fitting of 53 KA di-electric strength T- OIL of standard make
Filtration of existing T- oil up to desired strength and specifications.
Removing of damaged copper conductor and providing and fitting of new 19/18 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Removing of damaged copper conductor and providing and fitting of new 19/16 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Removing of damaged copper conductor and providing and fitting of new 7/18 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Removing of damaged copper conductor and providing and fitting of new 7/20 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Removing of damaged copper conductor and providing and fitting of new 3/20 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Removing of damaged copper conductor and providing and fitting of new 7/16 PVC insulated single core copper conductor. The job includes cost on account skilled/semi-skilled labour required for the execution of the work.
Repairing of damaged heating points by way of removing the damaged wire and providing and fitting of new 15 m , 2.5 sq. mm PVC flexible wire through the conduits . the job further includes removing damaged PVC conduit and P/F of new 15 feet long , 20 mm dia. pve conduit including P/F of 16A MCB 16 A On/off switch of SYSKA/Havells/L&T/ reputed make enclosed in steel enclosure including cost of lugs , Rubber cable gland etc .
Repairing of damaged lighting points by way of removing the damaged wire and providing and fitting of new 15 m , 1.5 sq. mm PVC flexible wire through the conduits . the job further includes removing damaged PVC conduit and P/F of new 15 feet long , 20 mm dia. pve conduit including P/F of 6A MCB 6 A On/off switch of SYSKA/Havells/L&T/ reputed make enclosed in steel enclosure including cost of lugs , Rubber cable gland etc .
Providing and fitting of LED Bulbs of B22 Base of Syska/reputed make 16 watt B22 base - 01 No.
Providing and fitting of 6 A SP MCB of L&T/Havells or any other reputed make (10ka)
Providing and fitting of 16 A SP MCB of L&T/Havells or any other reputed make.(10ka)
Providing and fitting of 32 A DP MCB Havells make enclosed in steel enclosure including cost of lugs, fasteners. (10 Ka)
Providing and fitting of 02 core, 16 Sq. mm aluminum armoured cable conductor. The job includes excavation of the soil and removing the damaged conductor and back filling of soil after fitting of new cable.
Repairs to lighting poles fitted in the premises of the pump station by way of disconnecting the electric supply to the lighting poles, extracting the damaged luminaries from the poles and then providing and fitting of 25 watt Havells/Syska make LED, 5700k light complete with all accessories to be fitted on the arm of existing tubular pole. All the tools and tackles, skilled labour required for the job is to be arranged by the firm.
Providing and fitting of 1.5 sq.mm PVC insulated copper conductor from LED light at top of the pole to the connection box at bottom of the pole
Providing and fitting of MCB box fabricated out of sheet metal duly painted along with 02 no. M.S Clamps Removing of damaged 630 A ACB of Havells/LNT make and Providing and fitting of new 630 A ACB having following specification: Current rating = 630 A Series = E Rated service voltage = 415 VAC Rated insulation voltage = 1000 V Rated impulse withstand voltage = 12 KV Frequency = 50 Hz. No. of poles = 03 Rated short circuit breaking capacity = 50 K A Utilization category = B Make = Havells (Titania) or Equivalent make
Removing of damaged CN-CS 1000C, 1000 A ACB of L&T make and Providing and fitting of new CN-CS 1000C, 1000 A ACB having following specification: Type = Thermal–magnetic release type DN1 Current rating = 1000 A Rated voltage = 415 VAC Frequency = 50 Hz Version = 03 pole MF Breaking capacity (Icu=Ics=Icw-1sec) = 50 K A Utilization category = B Make = L&T or equivalent
Extraction of 9 m long M.S tubular H.T tilted poles by way of removing all the damaged insulators , aluminum conductor and extraction of tilted bent poles erection of the same at appropriate place . The job includes the following works . a. Earth work in excavation in all kinds of soil Earth work : Quantity 2 x 1.5 x 4 = 12 cft 3.5 x 2 x 2.5 = 17.5 125 cft Total earth worth : 29.5 cft = 0.84 cm b. Providing and laying of cement concrete in 1: 2: 4 mixes including c/o shuttering and curing. Quantity : 2 X 1.5 X 4 = 12 cft. = 0.34 cm The job also includes cost on account of skilled/unskilled labour and tools and tackles required for erection of pole and carriage of material up to actual site of work.. The job also includes guy earthing of pole.
Providing, fixing and testing of 11 KV pin/bubble insulators brown Glazed porcelain insulator conforming to IS -731/1971 with amendments 1 to 5 Type – B with 320 mm minimum creapage distance and with lead/zinc thimbles along with G.I Forged Pin heaving small steal head as per IS-4186(P-1)1993 and IS – 2486(P-4)1989
P/F of 0.5 ACSR conductor to be laid over 11 Kv H.T Line . the job includes cost on account of skilled/unskilled labour and tools and tackles required for the work.
Removing of damaged link set and Providing and fitting of new 11 KV Link set complete (3 pieces ) of reputed make
Removing of damaged D.O set and Providing and fitting new of 11 KV D.O set complete (3 pieces ) of reputed make
Removing of damaged Lighting arrestor set and providing and fitting of new 11 KV Lighting arrestor set.
Extraction of 9 m long M.S tubular H.T. damaged poles by way of removing all the damaged insulators, aluminium conductor. The job further includes supply, installation, errection of M.S tubular poles of 9 Meters, 410 (SP-33) conforming to IS 2713 (Part-II) 1990. The job includes earth work in excavation in all kinds of soil and providing / laying of cement concrete of pole structure 3” below the pole base to 1’ above ground level & 1 ½’ around the pole in M-15 Mix. The pole shall be fitted / welded with 40 x 40 square inch in size and 4 mm thick MS plate at the bottom and having duly drilled holes at top at appropriate position for accommodating MS fasteners for holding insulators and safety devices. The Job also includes the cost of painting of poles with 2 coats of Al. and red oxide paint including black painting up to a height to 1.50 Meters from bottom and the top with a silver shade. The job includes c/o shuttering and curing, including all carriage up to the site of work (complete in all respects) .
Removing of damaged M.S cross arms along with bracing from the H.T. poles. The job further includes providing and fitting of 75 x 75 x x5 m , 4’-6” long channel iron cross arm including nuts and bolts required for the fixing of the cross arm on H.T poles and 45x45x5 mm, 3’ long angle iron bracing . The job further includes cost on account of skilled/unskilled labour, tools and tackles, ladder required for execution of the work and carriage up to the site of work complete.
A. Disassembling of 3phase, 630 KVA , 11/0.440 KV H.T Transformer from the bed and H.T/L.T Circuit, loading into TATA mobile then shifting it to workshop for conducting repairs, unloading the transformer by using channels and skilled/ semi-skilled labours and then back to the site of work by hiring TATA mobile. The job includes installation of H.T Transformer on bed. The job also includes refitting of L.T / H.T circuit complete and testing of H.T Transformer at full load. (The rate per job shall be allowed @ 17.07% of the quoted / Negotiated rate of whole item) B. Disassembling of transformer for assessing the nature of fault and damages. The job includes opening of top cover and removal of damaged coils. (The rate per job shall be allowed @ 13.28% of the quoted/ Negotiated rate of whole item) C. Supply of copper wire and Complete rewinding of copper wound H.T Coils as per norms and required specification .The rates are inclusive of old scrap. (Coils prefabricated as per relevant IE- Specification) approximate weight copper winding of each coil = 20 kg.The rate shall be inclusive of rebate on old scrap. (The rate per kg shall be allowed @ 1.71% of the quoted / Negotiated rate of whole item) D. Supply of copper strips and Complete rewinding of copper wound L.T Leg as per norms and required specification. ( L.T leg copper winding as per relevant IE- - Specification) approximate weight copper winding of each leg = 48 kg. The rate shall be inclusive of rebate on old scrap. (The rate per kg shall be allowed @ 1.71% of the quoted / Negotiated rate of whole item) E. Extraction of moisture from the winding assembly with core by way of heat treatment of the same in electric oven at least for 24 hrs at appropriate temperature. (The rate per job shall be allowed @ 22.76% of the quoted / Negotiated rate of whole item) F. Re- tapping of all connection leads and P/F of sleeves to HT/LT connections (The rate per job shall be allowed @ 7.59% of the quoted/ Negotiated rate of whole item) G. Fabrication, P/F of top lid gasket to the transformer and fitting of whole assembly into the transformer tank. (The rate per job shall be allowed @ 13.28% of the quoted / Negotiated rate of whole item) H. Providing and fitting of assorted size nuts and bolts (The rate per kg shall be allowed @ 0.42% of the quoted / Negotiated rate of whole item) I. Arresting of leakages in the radiator fins/tubes of the H.T transformer tank by welding / breezing / soldering at identified spot (approximate length of spot = 1cm). (The rate per job shall be allowed @ 4.55% of the quoted / Negotiated rate of whole item) J. Providing and fitting of 53 KA di-electric strength T- OIL of standard make (The rate per ltr shall be allowed @ 0.49% of the quoted rate of whole item) K. Filtration of existing T- oil upto desired strength and specifications. (The rate per liter shall be allowed @ 0.07% of the quoted/ Negotiated rate of whole item.) L. P/F of H.T brass Bush rod with washers, nuts and insulators to be fitted to 630 KVA H. T transformer (The rate per job shall be allowed @ 7.59% of the quoted rate of whole item .) M. P/F of L.T brass Bush rods with washers, nuts and insulators to be fitted to 630 KVA H. T transformer (The rate per job shall be allowed @ 9.48% of the quoted / Negotiated rate of whole item .)
Extraction of 9 Meters long M.S tubular H.T tilted poles along with Kiker peoples from the Nigeen lake by way of removing all the insulators , aluminum conductor and errection of 9m long pole by fastening kiker poles at appropriate place. The job includes arrangement of 2 No. big wooden boats, turn buckle, ropes required for extraction of the work. The job also includes cost on account of skilled/unskilled labour and tools and tackles required for erraction of pole. The work is to be carried out in the Nigeen lake and if any eventuality will core during the execution of the work the firm shall be responsible for the same.
Providing and fixing of 12 mm thick chequered shock proof electric insulating rubber mats of joyti/reputed make confirming to IS:15652 : 2006 With latest amendments. The job also includes removing of damaged rubber mats, cleaning of floor and applying of adhesive on the floor and fixing of rubber mats on the floor around and beneath the electrical panels, starters, motors, D.G Set room , stabilizer etc. so as to ensure safety against electric shock
1. Disassembling of C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) by way of disconnecting all the incoming and outgoing cables , dragging out the ACB , Disassembling it from the cradle . the job further includes disassembling the ACB into parts by way of removing arch Chute , fixed and movable contacts , spring charger motor, Pole assemblies etc. for assessment of damages. The job further includes re-assembling the Complete ACB and assembling it with the cradle and connecting all the incoming and outgoing cables. The job further includes servicing of the ACB By way of checking and cleaning all the parts, applying grease of appropriate grade and specifications to the every part of the ACB which require greasing. The skilled/unskilled labour, tools and tackles required for the job shall be arranged by the firm and setting and testing of ACB On full load. (The rate per job shall be allowed @ 3.08% of the quoted / Negotiated rate of whole item .) 2. Providing and fitting of Arch Chute( 440V)to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 1.64 % of the quoted / Negotiated rate of whole item) 3. Providing and fitting of Shunt release(SR) to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) type EA1: 240V/415 V AC) (The rate per job shall be allowed @ 2.77 % of the quoted / Negotiated rate of whole item) 4. Providing and fitting of Under Voltage release (UVR) Type MV 240 V/ 415 V AC to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 4.11 % of the quoted / Negotiated rate of whole item) 5. Providing and fitting of Earth Fault release (For DN1) Type EF1/EF2 ( 10% , 20 % In / 30%, 40%, 50% In ) to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) ) (The rate per job shall be allowed @ 2.72 % of the quoted / Negotiated rate of whole item 6. Providing and fitting of lock trip push button (LTPB) type AA/BB/CC/DD to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 2.73% of the quoted / Negotiated rate of whole item) 7. Providing and fitting of lockable trip Push button kit ( 3 I/C & 2 B/C) to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 14.38 % of the quoted / Negotiated rate of whole item) 8. Providing and fitting of spring charge indication micro switch to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 2.04% of the quoted / Negotiated rate of whole item) 9. Providing and fitting of JAW Contact Assembly to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 7.19% of the quoted / Negotiated rate of whole item) 10 Providing and fitting of fixed Arcing Contact to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 4.62% of the quoted / Negotiated rate of whole item) 11. Providing and fitting of moving arcing contact to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 4.62% of the quoted / Negotiated rate of whole item) 12. Providing and fitting of closing coil 110 V AC/DC / 240 V AC/ 220V DC to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 4.78% of the quoted / Negotiated rate of whole item) 13. Providing and fitting of CT for DNI Release to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 4.49% of the quoted / Negotiated rate of whole item) 14. Providing and fitting of PUSH BUTTON – RED/ GREEN to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 1.14% of the quoted / Negotiated rate of whole item) 15. Providing and fitting of main shaft assembly to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 3.39% of the quoted / Negotiated rate of whole item) 16. Providing and fitting of main Spring blue to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 5.33% of the quoted / Negotiated rate of whole item .) 17. Providing and fitting of spring charge motor 240 V AC / 110 V AC to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 28.63% of the quoted / Negotiated rate of whole item) 18. Providing and fitting of motor limiting switch to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 0.96% of the quoted / Negotiated rate of whole item .) 19. Providing and fitting of Twisted Link kit ( MF/MDO) to C-Power CN-CS 1000 C, 3 Pole, 415V Air circuit breaker (ACB) (The rate per job shall be allowed @ 1.38% of the quoted / Negotiated rate of whole item .)
Providing and fitting of conductor terminal thimbles of Dowells /reputed make duly crimped and tapped at conductor ends by hydraulic crimping tool of the following specifications. The job further includes removing of damaged conductor terminal thimble
100 Sq. mm aluminum
200 Sq. mm aluminum
100 Sq. mm copper heavy duty BS-4579
200 Sq. mm copper heavy duty BS-4579
Providing and fitting of power conductor , XLPE , PVC Tape/extruded inner sheathed, Armoured as per IS, 650/1100V Grade as per IS 7098 ( part 1) 1988 of the following specifications
50 sq. mm single core copper
70 sq. mm single core copper
95 sq. mm single core copper
Branch cutting of all the willow trees and popular trees grown along the 11 KV, H.T line by employing skilled labour. The job also includes cost on account of tools and tackles, ropes, ladders, mechanical saw required for the job. All tools and tackles shall be arranged by the firm. The job further involves its disposal up to dumping site as directed by engineer in charge at site.
Cutting and removing of trees which fell over the H.T Line due to snow fall/ wind storm. The job also includes cost on account of tools and tackles, ropes, ladders, mechanical saw required for the job to be arranged by the firm. The job further involves its disposal upto dumping site as directed by engineer in charge at site.
Asif Engineering Works
Bahir Brothers
M. G. ELECTRICALS
M/s ASIAN ELECTRICAL AND MECHANICAL WORKS
M/s ASIAN ELECTRICAL AND MECHANICAL WORKS
M/S Evergreen Enterprises
Bahir Brothers
M. G. ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .