Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹3.2 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.6 Cr+₹38.6 L (12.2%)Rejected-AOC | ₹3.6 Cr+₹38.6 L (12.2%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹4.2 Cr+₹99.8 L (31.4%)Rejected-AOC | ₹4.2 Cr+₹99.8 L (31.4%) | L3 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
24 Jun 2021, 6:00 pmClosed
Chief Engineer R and D Secunderabad
Chief Engineer R and D, Picket, Opposite Jublee Bus Stand Secunderabad
PROVISION OF PERMANENT ACCOMODATION FOR DSC PLATOON AT ANURAG HYDERABAD
2021_MES_428361_1
CA NO.CERD/SEC/TOKEN/60 OF 2019 -2020
Open Tender
Civil Works
Lump-sum
540 days
Hyderabd
As per NIT
8 documents required · 8 mandatory
₹2,000
GE I R and D Kanchanbhag Hyderabad
₹4.1 L
Yes
27 Jul 2021
5 Mar 2021
28 Jun 2021
5 Mar 2021
24 Jun 2021
10 Jun 2021
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.08) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Block of Married accommodation with Garage building for JCO complete all as shown on drawings and as specified.
Construction of Block of Married accommodation for 09 ORs in triple storey building complete all as shown on drawings and as specified.
Construction of Block of Single accommodation for 18 ORs (G+1) with ,unit shop ,dining hall and cook house & storage accommodation building complete all as shown on drawings and as specified.
Construction of Block of Office and Guard House in single storey building complete all as shown on drawings and as specified.
Construction of Cycle Shed complete all as shown on drawings and as specified.
Construction of Sentry Post complete all as shown on drawings and as specified.
Construction of Septic tank 100 users complete all as shown on drawings and as specified.
Construction of Soak well of size 2.4m dia and 4.5 M effecive depth complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for "EXCAVATION, EARTHWORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - II representing _______ % ________________ percent Above / Below the lumpsum price of `3,72,006.42 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ PCC ROAD AND CULVERT ” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `3,14,526.09 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `1,55,718.62 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `3,82,928.31 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “ INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `1,70,597.00 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `77,706.80 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VIII representing ______ % _________________ percent Above / Below the lump sum price of `3,10,707.20 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of `7,12,136.26 inserted by the MES in Schedule ‘A’ Part - IX
Schedule 'A' Part - X This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 11.00 to 67.00
Rough excavation ang getting out muck from old septic tank /aeration chamber exceeding 1.5m deep complete all as specified and directed ,
Forming of embankment /filling in low lying area using approved earth obtained from outside MD land with a lead not exceeding 1.5 km from the work place in layers not exceeding 25 cm thick including spreading ,levelling and watering as required and compacting using power toller 8-10 Ton finished size and shape complete all as specified and directed ,
Concrete bed to drain pipes of 450mm bore, using cement concrete 1:4:8 type D2 using 40mm graded stone aggregate including packing under and completely surrounding pipes with concrete after they are laid and tested, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including 20/25mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in block masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of sunken type pressed steel /welded mild steel terminal boxes made out of 1.6mm mild steel sheet including 3 mm thick laminated sheet cover cover for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light / celing fan/ exhaust fan point controlled by one 5 amps one way modular switch, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of MS terminal boxes s, laminated cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall deemed to be include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 14.00 here-in-before but for one 3 / 5 pin 6 Amp socket outlet point on independent board
All as per Sl. Item No. 14.00 here-in-before but for one 3 / 5 pin 6 Amp socket outlet point on same board
All as per Sl. Item No. 14.00 here-in-before but for one light point controlled by Two , Two-way switch
All as per Sl. Item No. 14.00 here-in-before but one bell point controlled by one push button on the same board with other swithes with independent cables .
All as per Sl. Item No. 14.00 here-in-before but for one 3/6 pin 16Amp socket outlet point on independent board but with 4.0sq.mm copper conductor cable with 4.0 sq.mm copper conductor cable as earth wire.
Factory made epoxy powder coated MCB distribution board TPN 6 way double door (VTPN MCCB DB)MCCB TPN as in comer ,with metal door IP -43 protection ,IK -09 as per IEC -61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and 200 Amps copper bus bar ,neutral bar ,standard DIN rail ,earth bar and cable ties for cable management ,top and bottom removable gland plates woth Knockout semi flush to wall and making good distrubed surfaces complete all as specified and directed.Note: All incomimg /out going MCCB/MCBs shall be measured and paid under appropriate item .
Factory made epoxy powder coated MCB distribution board TPN 4 way double door (VTPN MCCB DB)MCCB TPN as in comer ,with metal door IP -43 protection ,IK -09 as per IEC -61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and 200 Amps copper bus bar ,neutral bar ,standard DIN rail ,earth bar and cable ties for cable management ,top and bottom removable gland plates woth Knockout semi flush to wall and making good distrubed surfaces complete all as specified and directed.Note: All incomimg /out going MCCB/MCBs shall be measured and paid under appropriate item .
MCB DB SPN double door 2-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 100 amps rated busbar ,neutral & earthing link bar semi flush mounting to wall and making good distrubed surfaces complete all as specified and directed. Note: All MCBs shall be measured and paid under appropriate item .
Flame proof MCB 25 Amp double pole ,240 volts including LM6 enclosure complete all as specified and directed. .
MCCB 4 pole of 32 Amps fixed thermal & fixed magnetic 415 Volts with 16 KA ultimate breaking capacity ,thermal magnetic release with adjustable over load and short circuit protection with inbuilt earth leakage protection confirming to IS-13947& IEC-60947-2 & the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity ( Icu) ,MCCB shall be with suitable spreaders and phase barriers for each terminals complete all as specifeid and directed.
MCCB 4 pole of 25 Amps fixed thermal & fixed magnetic ,415 Volts with 16 KA ultimate breaking capacity ,thermal magnetic release with adjustable over load and short circuit protection with inbuilt earth leakage protection confirming to IS-13947& IEC-60947-2 & the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity ( Icu) ,MCCB shall be with suitable spreaders and phase barriers for each terminals complete all as specifeid and directed.
MCB TP 20 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity incliding electrical connection with the help of lugs/thimbles , complete all as specifeid and directed.
MCB SPN 10 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity incliding electrical connection with the help of lugs/thimbles , complete all as specifeid and directed.
MCB SP 20 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity incliding electrical connection with the help of lugs/thimbles , complete all as specifeid and directed.
MCB SP 6 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity incliding electrical connection with the help of lugs/thimbles , complete all as specifeid and directed.
Sub main wiring complete with 4 runs of 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit not less than 32mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four of runs of 6.0 sq.mm copper conductor, Two runs of 6.0 sq.mm copper earth continuity conductor and one run of not less than 32 mm dia conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 2.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 2.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, one run of 2.5 sq.mm copper earth continuity conductor and one run of 25mm dia conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 4.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 4.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4.0 sq.mm copper conductor, one run of 4.0 sq.mm copper earth continuity conductor and one run of 25mm dia conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
supply ,fixing and testing 4 feet LED surface & wall mounted batten LED luminaires 20Watts , with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalled LED light distribution high optically efficient serrated diffuser ,isolated multistage CCCV driver with voltage range 150-270 v AC ,temparature range 0 to 50 degree C CRI >85% ,power factor > 0.95 ,THD<10% colour temparature-6500k ,short circuit and over circuit protection surge pritection -3KV in CM ,safety extra low voltage safe level < 60V DC as per IS - 10322/iec- 60598 standard ,IP20 protected ,50000 burning hours ,with 70% of its initial lumen maintained ,Lumianire efficacy AC ,temparature range 0 to 50 degree C CRI >85% ,power factor 100lm /W fixed complete and including all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and directed . Make ; Havells Cat No - ENDURALINEARNEOB20WLED840SPCWH or technocommercially Equivalent in Phillips /Bajaj/Jaquar
Supply ,fixing and testing 2 feet LED surface & wall mounted batten LED luminaires 10Watts , with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalled LED light distribution high optically efficient serrated diffuser ,isolated multistage CCCV driver with voltage range 150-270 v AC ,temparature range 0 to 50 degree C CRI >85% ,power factor > 0.95 ,THD<10% colour temparature-6500k ,short circuit and over circuit protection surge pritection -3KV in CM ,safety extra low voltage safe level < 60V DC as per IS - 10322/iec- 60598 standard ,IP20 protected ,50000 burning hours ,with 70% of its initial lumen maintained ,Lumianire efficacy AC ,temparature range 0 to 50 degree C CRI >85% ,power factor 100lm /W fixed complete and including all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and directed . Make : Havells Cat No - ENDURALINEARNEOBS10WLED840SPCWH or technocommercially Equivalent in Phillips /Bajaj/Crompton Greaves
Supply ,fixing and testing 45W high efficient LED street light fitting aluminium pressure die cast housing parts for long life , pure polyester powder coated Dark GRAY housing high purity PMMA lenses for superior performance ,toughened glass with silicon gaskets for IP 65 protection , driver cover designed to suit top maintenance ,suitable for external pole dia ,upto 50mm , power factor >0.95 ,luminaire LUMEN OUTPUT -6440LM ,CCCV driver with voltage range 150-270 v AC ,temparature range 0 to 50 degree C CRI >85% ,power factor > 0.95 ,THD<10% CRI > 70 ,colour temparature-5700k ,surge pritection from high voltage -4.0KV in CM 50000 burning hours,Lumianire efficacy > 92lm/W fixed complete and including all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor and PVC conduit with fixing accessories for connection between juction box and street light complete all as specified and directed . Make : Havells Cat No - ENDURAPEARLNEOSL45WLED757SASYTOPC or technocommercially Equivalent in Phillips /Bajaj/Crompton Greaves
Supply ,fixing and testing 1 feet LED surface & wall mounted batten LED luminaires 7Watts , with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalled LED light distribution high optically efficient serrated diffuser ,isolated multistage CCCV driver with voltage range 150-270 v AC ,temparature range 0 to 50 degree C CRI >85% ,power factor > 0.95 ,THD<10% colour temparature-6500k ,short circuit and over circuit protection surge pritection -3KV in CM ,safety extra low voltage safe level < 60V DC as per IS - 10322/iec- 60598 standard ,IP20 protected ,50000 burning hours ,with 70% of its initial lumen maintained ,Lumianire efficacy AC ,temparature range 0 to 50 degree C CRI >85% ,power factor 100lm /W fixed complete and including all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and directed . Make : Crompton Greaves Cat No - LCL -07-CDL or technocommercially Equivalent in Phillips /Bajaj/Jaquar
Supply ,fixing and testing 9W LED bulbs complete all as specified and directed . Make : Bajaj Cat No - 830052-9WCDLB22 or technocommercially Equivalent in Phillips /CGj/Jaquar
Supply ,fixing and testing Fluorescent tube light fitting 1x36 w flame proof type FLP- WP made of aluminium alloy LM6, with electronic ballast ,bipin holders ,connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
Ceiling fan 5 star BEE rated ,milk white coloured complete 1200mm sweep with down rod and all accessories energy efficient suitable to function on 230V, single phase AC supply, complete and connecting with and including provision of three core 1.0sqmm cable flexible copper conductor from ceiling rose and requred length of down rod including marking MES Number on ceiling fan motor complete all as specified and directed.
Heavy duty exhaust fan 225mm sweep 240V 50hz 1400RPM single phase AC supply with metal body powder coated with protective steel bird gaurd on wall with all fixing arrangments to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on exhaust fan motor complete all as specified and directed.
Heavy duty exhaust fan 300mm sweep 240V 50hz 900RPM single phase AC supply with metal body powder coated with protective steel bird gaurd on wall with all fixing arrangments to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on exhaust fan motor complete all as specified and directed.
Flame proof Heavy duty exhaust fan 300mm sweep 240V 50hz 900RPM single phase AC supply with metal body powder coated with protective steel bird gaurd on wall with all fixing arrangments to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on exhaust fan motor complete all as specified and directed.
Heavy duty exhaust fan 450mm sweep 240V 50hz 900RPM single phase AC supply with metal body powder coated with protective steel bird gaurd on wall with all fixing arrangments to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on fan motor exhaust complete all as specified and directed.
Air circulator wall fans 230 Volts single phase oscillating 450 sweep suitable for wall mounting ,oscillation up to 90º and matal body powder coated with all fixing arrangments to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan including marking MES Number on fan motor complete all as specified and directed.
Single pole and neutral enclossure with two pin and earth plug and socket complete with on double pole MCB 20Amp ,240V complete all as specified and directed.( for A/C Point & Geysors )
Triple pole and neutral enclossure with three pin and earth plug and socket complete with on triple pole MCB 20Amp ,240V complete all as specified and directed.(Atta kneaders in kitchen)
Design, manufacture, supplying, installing in correct aligned position, making proper connections, testing and commissioning of following LV panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be indoor IP-42 rating, free standing, floor / wall mounting, sheet metal clad, cubicle, dust and vermin proof type compartmentalized design fabricated out of 16 SWG CRCA sheet steel, complete with aluminium bus bars of 200 Amp insulated with heat shrinkable sleeves and colour coded, separate earth bus bars to be provided through out the length of panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, numbering, danger plate etc as required as per specifications and drawings consisting of the followings:
Incoming: MCCB 4 pole 415 V, 100 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 25 KA, adjustable overload min 70-100% - 01 No. Metering & Indication: LED indicating lamps set RYB - 01 Set. Outgoing: MCCB 4 pole 415 V, 32 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% - 11 Nos (outgoing). MCB SPN 16 Amp 240V, 10KA, C curve - 01 No (outgoing). Multi function energy meter, 3 lines seven segmant display, 3 phase, 3 or 4 wire CT-PT operated multi function meter of class 1.0 accuracy with RS 485 and THD for V & I panel mounted 96 x 96 sqmm flush mounted case - 09 Nos. Multi function energy meter, 3 lines seven segmant display, single phase, CT-PT operated multi function meter of class 1.0 accuracy with RS 485 and THD for V & I panel mounted 96 x 96 sqmm flush mounted case - 01 No.
Design, manufacture, supplying, installing in correct aligned position, making proper connections, testing and commissioning of following LV panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be indoor IP-42 rating, free standing, floor / wall mounting, sheet metal clad, cubicle, dust and vermin proof type compartmentalized design fabricated out of 16 SWG CRCA sheet steel, complete with aluminium bus bars of 200 Amp insulated with heat shrinkable sleeves and colour coded, separate earth bus bars to be provided through out the length of panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, numbering, danger plate etc as required as per specifications and drawings consisting of the followings:
Incoming: MCCB 4 pole 415 V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 25 KA, adjustable overload min 70-100% - 01 No. Metering & Indication: LED indicating lamps set RYB - 01 Set. Outgoing: MCCB 4 pole 415 V,40 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% - 01 No (outgoing). MCCB 4 pole 415 V,32 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% - 01 No (outgoing). MCB SPN 16 Amp 240V, 10KA, C curve - 01 No (outgoing). Multi function energy meter, 3 lines seven segmant display, 3 phase, 3 or 4 wire CT-PT operated multi function meter of class 1.0 accuracy with RS 485 and THD for V & I panel mounted 96 x 96 sqmm flush mounted case - 01 No.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32mm x 6mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth 4mm , GI earth wire shall be protected by 15mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately
Supply, installation, testing and commissioning refrigerators electric driven(single phase ) capacity 200 litres frost free complete all as specified and directed.
Supply, installation, testing and commissioning water cooler electric driven single phase having approx storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour complete all as specified and directed.
Supply, installation, testing and commissioning desert cooler plastic /PVC body electric driven single phase having nominal air flow capacity of 5000 CuM per hour or nearest size Make: Coolest DC 2016 GLACIER Desert Air Cooler of Bajaj or technocommercially Equivalent in CG/ Havells
Supply, installation, testing and commissioning deep freezer hard top 200 litres capacity having single door complete all as specified and directed.
Supplying , installing, testing and commissioning outdoor type, step down 11 / 0.433 KV, HT with 3 phase and LT with 3 phase, 4 wire system double copper wound with Off Circuit Tap Changer arrangement on HT side for variation of secondary voltage with tapping range +5% to -10% in steps of 2.5% continious rating of 100 KVA (Level-II) confirming to IS: 1180 (Part-I): 2014 & IS: 2026-2011, Oil - IS:335:1993 including first fill of oil, control wiring between transformer to VCB with copper conductor with lugs & glands connection complete all as specified and directed. Make: CROMPTON / VOLTAMP / ITE GURGOAN / ESSENAR The quoted rates shall deemed to include the following: - (i) Temp rise in oil (degree C) : 40, by resistance (degree C) : 45. (ii) Ambient temperature : 50. (iii) Winding material : Copper. (iv) Type of cooling : ONAN. (v) Class of insulation: Class 'A' (vi) Vector group: Dyn11. (vii) Frequency (Hz) : 50. (viii) Phase: 3. (ix) Insulation level (kV/Kvp) HV: 28/75 LV: 3/-- (x) Primary connection (HV): Delta, primary volts: 11000V, primary phases: 3, primary wires: 3, primary rated current: 13.12A. (xi) Secondary connection (LV): Star, secondary volts: 433V, secondary phases: 3, secondary wires: 4, secondary rated current: 333.35A. (xii) Taps on primary / secondary winding for : +5% to -10% in steps of 2.5%.
SL Item No,55 Contd: (xiii) Primary / secondary voltage variation off circuit tap changer. (xiv) No. of switch positions: 7. (xv) Terminal arrangement HV: Bare bushings. (xvi) LV: Cable box. (xvii) Load losses (Level-II). (xviii) At 50% loading: 670 Watts (Max.). (xix) At 100% loading: 2680 Watts (Max.). (xx) Impedance (Z) (Percentage): HV-LV: 4.50%. SUBJECT TO IS:2026 TOLERANCE Porcelain bushings HV: 3 Epoxy bushing LV: 4 Painting (finish): PU light grey Shade No. 631 - IS: 5
SL Item No,55 Contd: TESTS - Routine tests as per IS: 1180 (Part-1): 2014 (i) Ratio test. (ii) Polarity (iii) Phase angle error measurement. (iv) I R values. (v) Winding resistance. (vi) Open circuit test. (vii) Short circuit & impedance test. (viii) Separate source voltage test. (ix) Induced over voltage test. (x) Pressure test. STANDARD FITTINGS AND ACCESSORIES: (i) Rating & Terminal marking plate - 01 No. (ii) Earthing terminals - 02 Nos. (iii) Lifting lugs - 02 Nos. (iv) Drain valve with blanking plate - 01 No. (v) Filter valve with blanking plate - 01 No. (vi) Conservator - 01 No. (vii) Conservator oil filling hole with cap - 01 No. (viii) Oil level indicator with min. marking - 01 No. (ix) Dehydrating breather - 01 No. (x) Conservator drain plug - 01 No.
SL Item No,55 Contd: (xi) Air release device - 01 No. (xii) Thermometer pocket - 01 No. (xiii) Pressure relief valve - 01 No. (xiv) Roller unidirectional - 04 Nos. (xv) Radiators (weld able type) - 02 Nos. (xvi) Bare bushings HV - 03 Nos. (xvii) Cable box LV - 01 No. (xviii) Separate neutral terminal - 01 No. (xix) Off circuit tap changer - 01 No. (xx) 100mm dia stem type thermometer - 01 No.
Supply, install test & commission of LT Panel board CPRI approved cubical type made of 2mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6mm angle iron bottom legs with minimum height of 20cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of 400 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital voltmeter - 01 No, ammeter - 01 No, CTs of suitable ratio and indicating LED type lamp for red, yellow and blue in incomer phases complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands etc, fixed on suitable PCC foundations complete testing and commissioning complete and consisting the following: - (drawing of panel and connections shall be approved by Engineer-in-Charge before starting the panel work and taking down old unsv from site as directed by Engineer-in-Charge). (a) MCCB, 4P, 250A, 50KA (as incomer) - 01 No. (b) MCCB, 3P, 125A, 10KA - 02 Nos (01 No. for panel at Md accn, 01 No. for panel at OTM). (c) MCCB, 3P, 32A, 10KA - 06 Nos (for misc accn like p/house, v/ball court, rel hall, street lights, spare). Make: L&T / Schneider / ABB / Havells.
Supply, install test & commission of LT Panel board CPRI approved cubical type made of 2mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6mm angle iron bottom legs with minimum height of 20cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of 200 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital voltmeter - 01 No, ammeter - 01 No, CTs of suitable ratio and indicating LED type lamp for red, yellow and blue in incomer phases complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands etc, fixed on suitable PCC foundations complete testing and commissioning complete and consisting the following: - (drawing of panel and connections shall be approved by Engineer-in-Charge before starting the panel work and taking down old unsv from site as directed by Engineer-in-Charge). (a) MCCB, TP, 125A, 16KA (as incomer) - 01 No. (b) MCCB, 3P, 63A, 10KA - 02 Nos (c) MCCB, 3P, 32A, 10KA - 03 Nos Make: L&T / Schneider / ABB / Havells.
Supply, install test & commission of LT Panel board CPRI approved cubical type made of 2mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6mm angle iron bottom legs with minimum height of 20cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of 200 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital voltmeter - 01 No, ammeter - 01 No, CTs of suitable ratio and indicating LED type lamp for red, yellow and blue in incomer phases complete alongwith provision of necessary cable entry / exit boxes for all incoming and outgoing cables with suitable cable glands etc, fixed on suitable PCC foundations complete testing and commissioning complete and consisting the following: - (drawing of panel and connections shall be approved by Engineer-in-Charge before starting the panel work and taking down old unsv from site as directed by Engineer-in-Charge). (a) MCCB, 4P, 125A, 50KA (as incomer) - 01 No. (b) MCCB, 3P, 63A, 10KA - 02 Nos (c) MCCB, 3P, 32A, 10KA - 04 Nos Make: L&T / Schneider / ABB / Havells.
LED street light fitting including drive lighting IP66 protection ,70W pressure die cast housing with toughned glass and individual high power LEDs the secondary optics complete all as specified and directed.
LED post top lantern 35 watts energy saving environmental freindly aluminium land scape luminaire with high power LED suitable for pole dia upto 76mm with all accessories complete all as specified and directed.
Timer switch 16A ,3 Pole 230V ,digital type suitable for street light disribution board complete all as specified and directed.
Supply and erect 2 pole structure on 11 metre steel tubular pole consisting of anti climbing device & cross arms complete all as specified and directed. Note : Excavation ,earth work ,PCC work shall be measured and paid seperately
Supply and spread stone dust of thickenss 50 mm in structure yard complete all as specified and directed.
1X30W LED road way lighting luminaries with pressure die -cast powder coated LED street light suitable for building light clear acrylic cover and complete accessories including drive with suitable connection complete all as specified and directed.
Brick masonry valve pit 450 X 450 X 450 mm (internal dimension) with Fly ash brick work 230 mm thick walls in CM 1:4, 100 mm tick PCC 1:2:4 type B-1 as in foundation concrete, bed/ floors, coping and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 X 40 X 6 mm angle iron frame 3.15 mm thick MS sheet cover with locking arrangements and one No. 50 mm size 4 leavers MS lock with key in duplicate including excavation and earthwork in soft/loose soil, painting steel surface with two coats black bitumenous paint over a coat of red oxide primer complete all as specified and directed.
Health faucet cast copper alloy ,chromium plated including 1 metre long CP flexible pipe with all fittings to fix screwd down for iton pipe complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately
M/s RL Pareek
R. Wadhumal and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .