Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC CHURAMONIPUR PO MAKARKOLE BANKURA 722144 | BANKURA | BANKURA | WEST BENGAL | 722144 | ₹11.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹11.0 LRejected-Finance | ₹11.0 L | L2 | Rejected-Finance Rate quoted above Lowest bidder |
| 3 | L3₹11.0 LRejected-Finance | ₹11.0 L | L3 | Rejected-Finance Rate quoted above Lowest bidder |
Tender Value
₹11.0 L
EMD Value
₹22,080
Closing Date
11 Mar 2026, 11:00 amClosed
Executive Engineer (AM)
OFFICE OF THE EXECUTIVE ENGINEER (AGRI - MECHANICAL) BANKURA (AGRI - MECHANICAL) DIVISION, ADMINISTRATIVE BUILDING PRANABANANDA SARANI, P.O. KENDUADIHI, DIST. BANKURA
Construction of Pump House , IW and Energisation work for Salkhara Mini RLI Scheme, , Block-Patrasayer,G.P.-Belut-Rasulpur, Mouza-Salkhara, JL No-64, Plot No-1366, 1367 Under Bishnupur(AM) Sub Division Under Bankura(A-M) Div,Under Core-Sector 25-26
2026_WRDD_1015358_1
WBWRIDDEEAM/BANeNIT56/CS/25-26
Open Tender
Project Work
90 days
EE AM BANKURA AM DIV
Please refer Tender documents.
4 documents required · 4 mandatory
₹22,080
13 Mar 2026
27 Feb 2026
13 Mar 2026
27 Feb 2026
11 Mar 2026
27 Feb 2026
PUMP HOUSE Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence)
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand
Cement concrete (1:3:6) with graded stone ballast (40 mm. size excluding shuttering) In ground floor (Pakur variety)
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding Brick work with Ist class brick in cement mortar (1 : 6). (a) In foundation and Plinth
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding Brick work with Ist class brick in cement mortar (1 : 6). (b) In superstructure , ground floor
12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. [water proofing as per item no 60 and non toxic paint
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. ( For Tor steel). (SAIL/ TATA/RINL)
Plaster (to wall, floor ceiling etc) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course , scaffolding/ staging as necessary at ground floor. (Excluding cost of chipping over concrete surface) (a) 15 mm thick (1:6) proportion.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg/sq. Mtr. and up to 16 Kg/sq. mtr.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
C) Bend 87.5 degree (i) 75 mm. Dia
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On steel surface (Normal gloss).Two coats (with any shade except white).
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor b) Three coats
Colour washing with "ELLA" with a coat of white wash priming including cleaning and smoothening surface thoroughly(ii) External surface( Ground floor) (b) Two coats
Carriage ( 4%)
INTERNAL WIRING Fitting of wooden pannel board of size 6ft. X 4ft. X 1 inch. with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C.
Fixing only Iron Clad/Sheet Steel TP/TPN switch fuse units with H.R.C. fuses on angle iron frame on wall (a) 100 Amps.
Fixing only Iron Clad/Sheet Steel TP/TPN switch fuse units with H.R.C. fuses on angle iron frame on wall (Deptt. supply) (a)63 Amps.
Fixing only 500 V Iron Clad/MS sheet metal busbar chamber on angle iron frame on wall (4 bars 100 Amps)
Fixing Voltmeter/energy meter with necy., screws & other fixing materials & making holes where necy. Incl. making connections(Deptt. supply)
Fixing Ammeter/energy meter with necy., screws & other fixing materials & making holes where necy. Incl. making connections
Wiring with supply 16 mm.dia 3.5 core 1100 volt grade PVC copper wire in the PVC flexible from 200 Amps. Main switch to bus bar chamber. (6 mtr. Long wire supplied by Deptt.)
Supply & fitting, fixing etc. complete of power indicator lamp.
Supplying & fixing EL Danger Board on wall a) 15cm x 10cm (6" x 4") (PWD /Page-D-13, Item No.-21(a))
Supplying & fitting, fixing of 100 Amp Cut Out.
Supply and fixing and Soldering Copper Socket flat type as required
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall. (b) Star-Delta starter / Oil immersed starter 7.5 HP for motor (upto 5 HP for lower ratings and above 5 HP upto 15 HP for higher rating) (Deptt. Supply)
Drawing inter connection between starter to motor by 10 sq.mm. P.V.C. insulated copper conductor (any approved make), 3 core 2 nos. 1100 volt grade P.V.C. conduit fitted with necessary bend, elbows, inspection pit etc. with brass coupling and cable protector by fixing with saddle on the wall and partly under the ground by cutting and mending good the floor where as one ft. apart the motor to be flexible conduit P.V.C. by metal and double earthing continuously by 10 SWG GI Wire. (20 mtr. long wire supplied by Deptt.)
Distn. Wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (2 mm thick) flused in wall incl. mending good damages to original finish ) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Avegage run 8 mtr.
Fixing only iron Clad/Sheet Steel Main Switchs/Isolators on Iron Legs/Flat Iron Frame/Angle Iron Frame on wall (Deptt. supply) 16 Amps On Iron legs
Excavation of soil for installation of Earth Elctrode and filling & ramming. (a) For soft soil
Earthing with 50 mm dia GI Pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long ), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level & restoring surface duly rammed as below. (a) For Soft Soil By ISI-Medium GI Pipe
(a) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulatiors etc. as required
Supplying & drawing inter connection between Bus bar chamber to 63 Amps main switch, Main switch to 6 KVA Capacitor & 6 KVA capacitor to 20 HP Star delta Starter / Oil Immersed starter E.T.C by 10 sq.mm. P.V.C. insulated copper conductor(any approved make), 3 Core, 1100 Volt grade P.V.C. conduit fitted with necessary bend, elbows, inspection pit etc. with brass coupling and calbe protector and earthing by 10 SWG GI Wire as per I.E.C. regulation. (15 mtr. long wire supplied by Deptt.)
Supply & Drawing connection by 6 sq.mm. single core copper wire (any approved make) from D.P.I.C. Switch to Meter bord of W.B.S.E.D & CL with 3/4" flexible conduit including drawing earth wire of 18 SWG Copper wire. (8 mtr. long wire supplied by Deptt.)
Fitting, fixing and interconnecting the 6 KVA Capacitor JAVIC/KELTRON from bus bar by loop wiring with 660 Volt grade
(b) Supply & Fitting for Lamp & Shade
Supply (Fitting & Fixing) shack proof pad 6' x 3' x 1/2" with ISI make.
Submission of Test Form in the prescribed form obtaining from W.B.S.E.B. after mager test by a licenced Electrical supervisor and contractor having competency certificate in Part-I, II, XI, IV, VI-A, VI-B, VII-A.
Add GST @18% for the item No (1 to 49) on 225757.23
cess 1% on for the item No (1 to 50) on 266393.53
Electro motor pump set ISI marked IS-12615 & IS-6595 , 50 m3/hr, 18 m head (5 H.P)
Quotation chagre (including Supervision Charge & Security Deposite)
ENERGISATION OF RLI PCC POLE 9MTR. LONG
MS. CHANNEL 100X50X6 mm
MS. CHANNEL 75X40X6 mm
MS. ANGLE 65X65X6 mm
MS. ANGLE 50X50X6 mm
MS. FLAT 65X6 mm
GI STAY SET HT (1830 X 20 MM) WRKG LD 7900KG
GI STAY WIRE 7/3.15 MM
PORCELAIN GUY INSULATOR HT
11KV POLYMER COMP WH FTTG PIN INSL 5KN
11KV POLYMER COMP WH FTTG DISC INSL 45KN
COMPOSITE H/W FITTGS FOR 30/50S MM COND
COND ACSR RBT 50SMM
DTR 25 KVA 11/0.433 KV
LT Dist kiosk for 25 KVA
ISL 11KV 200A TPGO
1.1 KVPVC4C 25 SMM AL CABLE
G.I EARTH SPIKE 1833 X 20 MM
G.I WIRE 4MM
G.I WIRE 5MM
GI TURN BUCKLE
11KV V BRACKET for PCC POLE 9MTR. LONG
11KV TOP ADOPTOR for PCC POLE 9MTR. LONG
ERECTION OF SINGLE PCC POLE 9 MTR.LONG WITH FITTINGS
ERECTION OF DOUBLE PCC POLE 9 MTR WITH FITTINGS
GROUNDING OF HT STAY SET
ERECTION OF EARTHING COMPLETE
STRINGING & SAGGING OF ACSR 50 SQ MM 3 WIRE
FIXING OF CRADDLE GUARD BRACKET ON SP
FIXING OF CRADDLE GUARD BRACKET ON DP
FIXING OF LEAD WIRE 30 TO 60 MTR 2W
SURVEY OF 11 KV LINE OH LINE
FIXING OF 11 KV TPGO INSULATOR
ERECTION OF D.P. S/STN STRUCTURE USING 9 MTR PCC POLE
ERECTION OF 25 KVA DTR COMPLETE
FIXING OF KIOSK SINGLE SWITCH
DTR NATURAL EARTHING
FIXING OF "T" OFF BRACKET ON SINGLE POLE
FIXING OF 3 PHASE S/C. SERVICE CONNECTION
Add GST @ 18% on item no (77 to 95) LABOUR cost i.e. 18% of Rs. 89084.76
Add CESS @ 1% on item no (77 to 96) AND SL NO 97 Total cost i.e. 1% of Rs. 105120.01
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 0.09 MB
BOQ_2496533.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid