Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC NEAR MPEB OFFICE DHANA DISTT SAUGOR MP 470228 | DHANA | SAUGOR | MP | 470228 | L1 | Accepted-AOC aoc | |
| 2 | L2₹32.1 L+₹20,165 (0.63%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest Bid | |
| 3 | L3₹33.1 L+₹1.2 L (3.73%)Rejected-Finance 5 21 SADAR BAZAR SAUGOR MP 470001 | SAUGOR | SAGAR | MP | 470001 | L3 | Rejected-Finance 3rd Lowest bid | |
| 4 | L4₹37.0 L+₹5.1 L (15.9%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bid | |
| 5 | L5₹38.3 L+₹6.4 L (20.0%)Rejected-Finance BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L5 | Rejected-Finance 5th lowest bid |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
4 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Saugor
GE Saugor
SPL REPAIR TO CERTAIN EM INSTALLATIONS IN AREA-II UNDER GE SAUGOR
2022_MES_510416_2
GE/SGR/TOK-66 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Saugor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER SAGAR
₹61,000
Yes
17 May 2022
22 Mar 2022
6 Apr 2022
22 Mar 2022
4 Apr 2022
23 Mar 2022
60 days
Amount
M&L for for PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregates) on roof top as a leveling course / padding to maintain the slope, finished the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for rendering 10mm thick on fair faces of concrete surfaces in CM (1:3) in ceiling mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed (Note:-Water proofing compound shall be measured and paid separately)
M&L for applying three coats of white wash on new ceiling surface including preparation of surfaces complete all as specified and directed .
M&L for chipping removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debries out side the premises etc , including errection of double steel scaffolding, covering with green cloth and all the safety measures/ precautions and remove the debries outside MD land, complete all as specified and as directed. (Hard concrete should not be removed by force).
Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition whenever required) complete all as specified and as directed.
M&L for cleaning existing reinforcement with wire/rotary wire brush,making the surfaces free from loose material dirt etc, complete, applying two coats of alkaline rust converting primer FEOVERT or equivalent specification confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and directed.
S&F in replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET_RB complete all as specified and directed.
M&L for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/Protectsil CIT/Ferogard 903 on concrete surface (This inhibitor shall have migratory kind of properly which permits the material to migrate to a vertual extent of 100 mm, through pores of concrete. inhibiting the corrosion and de-passivating the electro-chemical reaction. It should have property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete complete all as specified and directed
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia 50 to 100mm deep holes in structural members at the intervals of 500mm center to center in staggered manner or as directed by Engineer-in-charge in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes, clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles, insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machined to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min 12hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting wihtout damaging structural elements.
M&L for providing and applying structural grade EPIBOND-21-LP or equivalent specification prior to appllication of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old contrete and new concrete complete all as specified and directed
M&L for providing and applying jacketing under slab, RCC members with micro concrete (Molith-MC) M40 including all lifts, shuttering,drilling holes and fixing shear anchor as per specifiation complete all as specified and directed. Note: Reinforcement shall be measured and paid separately. (Rates including jacketing,formwork and micro concrete)
Supply only integral water proofing compound complete all as specified and directed
M&L for provn of water proffing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/sqm comprising with following items including taking down of old roof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces including cleaning, brushing and watering to joints and grooves and removing the same to a distance exc 250 mtr and not exc 500 mtr from the roof of height 3 to 9 m height complete all as specified and directed:-
The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. For cast iron drain outlets a groove shall be cut as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab (Note:-Water proofing compound shall be measured and paid separately)
Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.
Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm
Laying of water proofing treatment of weight not less than 3 Kg / sqm APP modified polymeric water proofing membrane composed of 100 micron (+10% ) high density polyethylene sheet ( HMHDPE) as center core, which is sandwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.
Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane
Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directed at site .
Demilotion of Stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons, etc., complete all as specified and directed
M&L for moorum/red bajri filling in floors or pavings laid in layers not exc 15cm thick spread levelled and rammed including watering complete all as specified and directed
M&L for broken stone or boulders hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregates) as in plinth protection 75mm thick finishing cement concrete surfaces even & smooth without using extra cement including filling of joints with bituminous compound complete all as specified and directed
M&L for brick work with kiln burnt bricks (old size) built in CM (1:6) using sub class 'B' bricks straight or curved on plan exceeding 6 meter mean radius complete all as specified and directed.
M&L for complete removal of existing treatment mechanically and applying two coats exterior weather coat ( Apex paint or equivalent) over one coat of exterior primer, including properly making of v shape crakes and filling of all crakes with crakes seal incl. preparation of surfaces of old decorated walls complete all as specified and directed
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts similar work conforming to Fe.290.Gde-E-16 complete all as specified and directed
M&L for 1.25 mm thick mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified and directed
M&L for two coats of synthetic enamel paint over a coat of red oxide primer over 10 cm width or girth including preparation of new steel surfaces such as removing all splashes, drops, dirt, etc., complete all as specified and directed
maharaja construction and suppliers
pal enterprises
shivansh traders
dipangashu barick and associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .