Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | ₹23.8 L | L1 | Accepted-AOC AOC ISSUED |
| 2 | L2₹24.4 LRejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹24.4 L | L2 | Rejected-Finance that the bid
is not L1 |
| 3 | L3₹24.7 LRejected-Finance 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | ₹24.7 L | L3 | Rejected-Finance that the bid
is not L1 |
| 4 | L4₹26.1 LRejected-Finance NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | ₹26.1 L | L4 | Rejected-Finance that the bid
is not L1 |
| Sl No | Description | Qty | Unit | T.D.K. ENTERPRISE L3 | S. A. ENTERPRISE L2 | NARAYAN CHANDRA DAS L4 | STANDARD BUILDERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | I) EI Work:--
A. Dismantling of E.I, A.C, F.D.A system:
Dismantling of existing electrical installations, fire detection system, split & concealed split type air-conditioning units including copper pipeline, IDUs, ODUs, safety cage, platform after necessary disconnection by maintainging normalcy and co's own tools & tackles and keeep the materials at the store as per direction of EIC | 1 | item | 5,000 ₹5,000 | 5,000 ₹5,000 | 8,000 ₹8,000 | 10,000 ₹10,000 |
| 2.00 | B. Distribution of Power:
Supplying and fixing 415 V, d-sine, 4-Pole MCCB, DN3-400N type, 250A-320A thermal release range, 50kA breaking capacity(Icu) with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting on angle iron frame in existing DBs / enclosure and necessary connection with four pole DN3 spreader terminal and extended rotary handle. Necessary connection should be made from existing LT panel including necessary drilling of holes in bus-bar, cutting of gland plate & mending good the damages to original finish as per direction of EIC(make-- Legrand/ ABB/ Siemens/ LK) | 1 | Each | 42,720 ₹42,720 | 48,525 ₹48,525 | 25,500 ₹25,500 | 1,35,000 ₹1,35,000 |
| 3.00 | Supplying and fixing MCCB SS enclosure with IP20/30 protection, powder coated provision for housing 415V, DN3-400N type, Four pole (4P) MCCB, spreader link, rotary handle etc. on suitable angle/ flat iron frame incl. painting, connectionon on wall & mending good the damages to original finish & provision for earthing attachment as per direction of EIC (make-- Legrand/ ABB/ Siemens/ LK) | 1 | Each | 7,600 ₹7,600 | 11,500 ₹11,500 | 4,200 ₹4,200 | 10,000 ₹10,000 |
| 4.00 | Supplying and fixing 415V, 315/320A, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Make: Siemens/ L & T/ HPL) | 2 | Each | 29,500 ₹59,000 | 29,540 ₹59,080 | 12,150 ₹24,300 | 45,000 ₹90,000 |
| 5.00 | Supplying and fixing 415V, 315/320A, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (make-- Legrand/ ABB/ Siemens/ LK) | 1 | Each | 27,500 ₹27,500 | 28,420 ₹28,420 | 25,000 ₹25,000 | 40,000 ₹40,000 |
| 6.00 | C. Cables & Cable tray:
Supply of 1.1KV grade, Al. armoured PVC/XLPE cable (Polycab/Glostar/ RR kabel/KEI/Havells) with 2X10 SWG GI wire as mentioned below :
a. 4 core 240 sq. mm. | 165 | RM | 2,370 ₹3,91,050 | 2,716 ₹4,48,140 | 2,950 ₹4,86,750 | 2,100 ₹3,46,500 |
| 6.10 | b. 4 core 300 sq. mm. | 485 | RM | 2,920 ₹14,16,200 | 3,071 ₹14,89,435 | 3,630 ₹17,60,550 | 2,650 ₹12,85,250 |
| 7.00 | Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
a. 4 core 240 sq. mm. | 50 | RM | 162 ₹8,100 | 1 ₹50 | 150 ₹7,500 | 100 ₹5,000 |
| 7.10 | b. 4 core 300 sq. mm. | 370 | RM | 162 ₹59,940 | 1 ₹370 | 150 ₹55,500 | 100 ₹37,000 |
| 8.00 | Laying of following size cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
a. 4 core 240 sq. mm. | 80 | RM | 120 ₹9,600 | 1 ₹80 | 100 ₹8,000 | 100 ₹8,000 |
Tender Value
₹28.1 L
EMD Value
₹56,200
Closing Date
19 Jan 2026, 1:00 pmClosed
EE-II KNHED PWDte.
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata- 700073
Electrical works in DSA Lab situated at ground floor of Green building for proposed new DSA Cath Lab machine.
2025_WBPWD_978251_1
WBPWD/EE-II/KNHED/NIQ-71/ 2025-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹56,200
OFFICE OF THE EE KNHED PWDte.
2 Jul 2026
22 Dec 2025
21 Jan 2026
22 Dec 2025
19 Jan 2026
30 Dec 2025
29 Dec 2025
I) EI Work:-- A. Dismantling of E.I, A.C, F.D.A system: Dismantling of existing electrical installations, fire detection system, split & concealed split type air-conditioning units including copper pipeline, IDUs, ODUs, safety cage, platform after necessary disconnection by maintainging normalcy and co's own tools & tackles and keeep the materials at the store as per direction of EIC
B. Distribution of Power: Supplying and fixing 415 V, d-sine, 4-Pole MCCB, DN3-400N type, 250A-320A thermal release range, 50kA breaking capacity(Icu) with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting on angle iron frame in existing DBs / enclosure and necessary connection with four pole DN3 spreader terminal and extended rotary handle. Necessary connection should be made from existing LT panel including necessary drilling of holes in bus-bar, cutting of gland plate & mending good the damages to original finish as per direction of EIC(make-- Legrand/ ABB/ Siemens/ LK)
Supplying and fixing MCCB SS enclosure with IP20/30 protection, powder coated provision for housing 415V, DN3-400N type, Four pole (4P) MCCB, spreader link, rotary handle etc. on suitable angle/ flat iron frame incl. painting, connectionon on wall & mending good the damages to original finish & provision for earthing attachment as per direction of EIC (make-- Legrand/ ABB/ Siemens/ LK)
Supplying and fixing 415V, 315/320A, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Make: Siemens/ L & T/ HPL)
Supplying and fixing 415V, 315/320A, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (make-- Legrand/ ABB/ Siemens/ LK)
C. Cables & Cable tray: Supply of 1.1KV grade, Al. armoured PVC/XLPE cable (Polycab/Glostar/ RR kabel/KEI/Havells) with 2X10 SWG GI wire as mentioned below : a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Laying of following size cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : a. 4 core 240 sq. mm.
b. 4 core 300 sq. mm.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support with 25X25X3mm angle iron support i. 300 x 50 x 1.25mm (18SWG) with 25x25x3 angle iron support
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. i. 300 x 50 x 1.25mm (18SWG)
Do-- Do-- tray tee i. 300 x 50 x 1.25mm (18SWG)
Do-- Do-- tray cross member i. 300 x 50 x 1.25mm (18SWG)
Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
II) Fire Detection system: Re-Commissioning the existing 4 Loop Intelligent addressable Fire detection panel after dismantling of devices as per direction of EIC
Making necessary drawing of total installation and submitted to the office as per direction of EIC.
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type medium quality Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ Polycab) on the surface of the wall.
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) (brand should be used as per parity with the existing system at site)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) (brand should be used as per parity with the existing system at site)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) (brand should be used as per parity with the existing system at site)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) (brand should be used as per parity with the existing system at site)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) (brand should be used as per parity with the existing system at site)
(Rate should be quotated including all taxes and duties, GST .)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.