Driller-in-Charge. BMSD(D)
Office of the Driller-in-Charge. Bankura Mechanical Sub-Division (Drilling). P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102
Servicing and rectification work at 315 KVA Transformer-I, AVR, LT and HT Panel of 11 KV Sub-station of Water Supply Scheme for Pathardoba and its adjoining Mouzas under Simlapal Water Supply Scheme, Block-Simlapal under BMD, PHE Dte.
2026_PHED_5073822_9
WBPHED/BMSD(D)/NIeT- 01 OF 2026-2027
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Ailakundi
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
Yes
24 Sept 2026
24 Sept 2026
7 Oct 2026
24 Sept 2026
5 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending the site at Pathardoba, Bankura District with carrying different Testing, Servicing kit/machine like carrying oil filter machine, BDV testing set, Insulating Resistance Checking machine (1 KV, 2.5 KV, 5 KV) 3 Phase Variac, Current Injection machine/ kit, Voltage injection machine/kit, Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBS, Wires & Cables, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Transformers, VCBS with connecting HT, LT cables. | 1 | Item | -148 | - |
| 2 | Fault finding after disconnection of incoming and outgoing power line, earthing attachment, and instrument connection from 11 KV Sub-station of Pathardoba water supply scheme, Block-Simlapal as per the direction of EIC. | 1 | L.S | -147 | - |
| 3Supply and delivery of the following items for AVR | |||||
| 3.1 | Silica Gel | 1.5 | /kg | -145 | - |
| 3.2 | PCB card as per existing | 1 | Each | -144 | - |
| 3.3 | Voltage Controller Potentiometer (1K) | 1 | Each | -143 | - |
| 3.4 | Auxiliary NO contact block for Contactor | 5 | Each | -142 | - |
| 3.5 | Auxiliary NC contact block for Contactor | 3 | Each | -141 | - |
| 3.6 | 100VA, 240V/110V Control Transformer | 1 | Each | -140 | - |
| 4 | Rectification and restoration of AVR control operation by carrying out necessary inspection, testing and fault identification of the existing AVR control circuit, disconnecting the defective components and replacing 1 No. PCB Relay Card, 1 No. Voltage Controller Potentiometer (1K), 1 No. Auxiliary Contactor and 1 No. Control Transformer, including removal of defective components, fitting and fixing of new components, making necessary electrical connections, checking the control circuit, testing the AVR control operation and commissioning the AVR for satisfactory and stable operation, complete in all respect as per the direction of the E.I.C. | 1 | L.S. | -139 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 28.02 MB
Tendernotice_2.pdf
PDF • 1.11 MB
BOQ_5162157.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .