Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder for the work | |
| 2 | L2₹22.9 L+₹3.1 L (15.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.5 L+₹3.8 L (19.1%)Rejected-Finance NEAR MPEB OFFICE DHANA DISTT SAUGOR MP 470228 | DHANA | SAUGOR | MP | 470228 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹23.7 L+₹3.9 L (19.9%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹25.2 L+₹5.5 L (27.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
28 Dec 2021, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
SPECIAL REPAIR TO BLDG NO PB-45 OF NCO ACADEMY AT DHANA MIL STN UNDER AGE(I) DHANA
2021_MES_489390_1
83700/E8
Open Tender
Civil Works
Item Rate
180 days
DHANA
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
AGE (I) DHANA
₹48,400
Yes
25 Jan 2022
20 Nov 2021
30 Dec 2021
20 Nov 2021
28 Dec 2021
16 Dec 2021
20 Nov 2021 - 16 Dec 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including WC complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
M & L for brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Supply only integral water proofing compound.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on walls and applying two coats of white wash complete all as specified and as directed.
M & L for 1.5 mm thick wall care putty on wall complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed
M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed
M & L for preparing new plaster surfaces walls including chajjas, facias etc including filling of holes and applying 1.5 mm thick wall care putty as per manufacturer's instructions and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for complete removal of existing finish on walls including chajjas, facias etc. including filling of holes and applying 1.5 mm thick wall care putty as per manufacturer's instructions and applying two coat of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for complete removal of existing treatment and preparation of surfaces and applying two coats of cement base paint complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for ceramic floor tiles as per IS 15622: 2017 and IS 13712: 2019, group B IIa, anti-skid, glazed, unpolished, rectified, area of each tile exceeding 0.04 sqm but not exceeding 0.12 sqm, length less than 360 mm, minimum 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for ceramic wall tiles as per IS 15622: 2017 and IS 13712: 2019, group B III, glazed, unpolished, rectified, area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 7 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for 20 mm ± 1 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade over and including 15 mm thick screed in cement mortar 1:4 including grinding and polishing complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 20 mm ± 2 mm thick over and including cement screed bed of 15 mm thick in cement mortar 1:4, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 mm ± 2 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on and inlcuing backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
M & L for mirror polishing on marble/ granite/ Kota stone/ stone works wherever required using polishing with carborundum stone and buffing top with aluminium or tin oxide abrasive powder to give high gloss finish complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, ground or obscured or frosted, 4.8 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Providing and fixing of double rebate openable/fixed windows made of galvanized steel colour coated/powder coated (base steel as per IS 513 of “D" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 mm, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 72 mm X 55 mm, centre mullion section 72 mm X 50 mm, shutter section 47 mm X 20 mm, fly mesh section 40 mm X 20 mm and the fixed glass beading section 12 mm X 12 mm, outer frame and mullions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitre joined with corner bracket, centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 5 mm thick plain float glass and stainless steel Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10 mm Square bars welded to 6 mm X 12 mm flat at a distance 150 mm c/c (pitch) etc. all as per window ECO4000 series of NCL BUILDTEK LTD Limited or equivalent of Make as mentioned under Appendix “B” of Particular Specifications complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
S & F drapery rods (curtain rods) of 25 mm outer diameter, designed on electric resistance welded mild steel pipe having a corrugated virgin PVC extrusions reinforced to minimize friction and eliminate scratches with colour matching brackets and finials etc. of approved colour /shade/design wherever necessary with anchoring arrangements complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 80/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection all as specified and as directed.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and keeping aside for credit complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 15 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
S & F CPVC pipes for potable hot and cold water distribution, nominal size 15 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 on walls/ ceiling or laying in floors complete all as specified and as directed.
S & F CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 on walls/ ceiling or laying in floors complete all as specified and as directed.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S & F wash basins with pedestal, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, bright finish complete all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in repairs 32 mm nominal size, waste coupling of PTMT (half or full threaded), minimum weight 45 grams with including silicone sealant complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F in repairs grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed.
Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed.
Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction all as specified. (Note;- water proofing compound shall be measured and paid separately as supply only)
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP membrane HMHDPE 4 Kg plain (thickness 2.8 mm) (total weight of the finished membrane not less than 4.0 kg/ sqm ± 5 % per sqm) confirming to IS 16540: 2017 over a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25⁰C, 0.87-0.89 kg/ litre and viscosity 70-160 cps, laying over the primer coat using Butane Torch and sealing all joints, overlapping etc. as per Annex D of IS 16540: 2017 complete all as specified and as directed.
M & L for applying bituminous aluminium paint @ 0.15 kg per sqm over water proofing membrane complete all as specified and directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, wall light fittings , tube light fittings, surface light fitting , ceiling light fittings , any types of fittings etc. removing materials to store for keeping in safe custody or for taking on credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down main switch/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.
Taking down ceiling fan/ exhaust fans, any sweep including disconnection of electric connection and removing the blades in safe for reinstalling complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 3 pin) with common earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F sheet metal enclosure with socket plug top and MCB DP enclosure with two pin & earth plug and socket complete with MCB DP 20 Amps 240 volts complete all as specified and as directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and directed by Engineer-in-charge. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and directed by Engineer-in-charge. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
S & F Sheet metal enclosures made out of CRCA mild steel sheet, powder coated vertical DB TPN 12 way 415 Volt, dust and vermin proof suitable MCCB as incomer and MCB as outgoing, TPN, 415 V, 50 Hz with suitable size copper busbar and neutral link as per catalogue No. DHDLVDRWAOFO12 of Havells or equivalent of Make mentioned under Appendix "B" complete including MCCB rated current(In): 160A, ultimate short circuit breaking capacity (Icu): 25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply and MCB single pole (SP), C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 12 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
S & F LED light fittings consisting separate batten and tube lights, including both batten and tube lights, 1 X 18 W, 220 V, AC, decorative box type, epoxy powder coated white extruded aluminium channel housing, lumen output of minimum 1800, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 kVs, protection grade IP20, CRI greater than 80%, THD less than 10%, power factor of minimum 0.95, life span of minimum 50000 working hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F LED street light/ building security light nominal power 25 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, lumen output of minimum 4500, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. ENDURAPEARLSL25WLED757SASYTOPC of Havells or equivalent of Make mentioned under Appendix "B" including 1.5 metre medium grade galvanized iron pipe bracket made of suitable nominal bore and necessary nuts, bolts, clamps including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose of connectors to fan complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F powder coated, minimum thickness 50 micron, aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. Note : (i) Glass panes, wire mesh & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
S & F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Dismantling structural steel work including doors, gates but excluding framed truss etc into primary parts.
M/S RAKESH TRADERS
siddhant construction
M/S JAINENDRA KUMAR JAIN
SUNIL KUMAR KORPAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .