| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹55.1 L+₹11.2 L (25.6%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Rejected_Fin | |
| 3 | L3₹57.0 L+₹13.1 L (29.8%)Rejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance Rejected_Fin |
Tender Value
₹46.8 L
EMD Value
₹93,513
Closing Date
26 Mar 2024, 12:00 pmClosed
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
75 D H Road Khidderpore Kolkata 23
Electrical Works for Vertical Extension with the provision of New Lift Well and stair block at old PMR building along with upgradation and face lifting of old and New PMR building including Horizontal ...Air Conditioning Works.
2024_WBPWD_680036_1
WBPWD/EE-I/KSHED/Q91/23-24
Open Tender
A/C ORG
Item Rate
30 days
SSKM Hospital Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹93,513
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
4 Apr 2025
5 Mar 2024
28 Mar 2024
5 Mar 2024
26 Mar 2024
12 Mar 2024
12 Mar 2024
Amount
S&D of minimum 13KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRV16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F).
S&D of minimum 10.55KW nominal cooling capacity ceiling suspended [Concealed] medium static, Split Air Conditioner with R410A / R407C / R-32 Refrigerant having single Scroll Compressor / Swing compressor for inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote, filter & all other accessories (Make : DAIKIN model FDMF100BRV16/ RZMF100BRV16 / Mitsubishi heavy industries model FDUM100CSV-S6/FDC100CSV-S6 / O General model ARG36F/AOG36F).
S&D of minimum 7KW nominal cooling capacity ceiling suspended [Concealed] medium static, Split Air Conditioner with R410A / R407C / R-32 Refrigerant having single Rotary Compressor / Swing compressor for inverter machine, suitable for operation on 240V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote, filter & all other accessories (Make : DAIKIN model FBQ71DV1+RZQ71KCV4A Mitsubishi heavy industries model FDUM71CNV-S6 +FDC71CNV-S6 O General model ARG25F + AOG25F).
S&D of minimum 5.27KW nominal cooling capacity ceiling suspended [Concealed]medium static, Split Air Conditioner with R410A / R407C / R-32 Refrigerant having single Rotary Compressor / Swing compressor for inverter machine, suitable for operation on 240V,+_ 5% , 50Hz,1Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote, filter & all other accessories (Make : DAIKIN model FDXS60CVMA+RXS60FVMA Mitsubishi heavy industries model FDUM50CNV-S6 +FDC50CNV-S6/ O General model ARG18F + AOG18F).
Installation testing & commissioning of above AC machines at Gr floor fixing the indoor unit suspended from ceiling with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on wall with two number 1.2mt long MS "C" channel of sizes 80mmX40mmX 6mm by one side grouted into the wall as per direction of EIC.(MS " C" channel must be must be painted by 1 coat of RO primer and 2 Coat of enamel paint)
Installation testing & commissioning of above AC machines by fixing the indoor with two number 2 mt long MS equal angle of sizes 40mmX40mmX 6mm to fixed by welding in both end to the existing joist or one side grouted in wall and other side welded in joist as required. The indoor unit suspended from this angle support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on roof of 2nd floor by fabricated rectangular shape MS chair with 4 nos leg with 1.5 ft height.MS chair should constructed with 50X 50X 6 MS Angle.Structure should be suitable for place outdoor unit . (MS Anglel must be painted by 1 coat of RO primer and 2 Coat of enamel paint)
Installation testing & commissioning of above AC machines fixing the indoor unit suspended from ceiling with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on roof of 2nd floor by fabricated rectangular shape MS chair with 4 nos leg with 1.5 ft height.MS chair should constructed with 50X 50X 6 MS Angle.Structure should be suitable for place outdoor unit . (MS Anglel must be painted by 1 coat of RO primer and 2 Coat of enamel paint)
Installation testing & commissioning of above AC machines fixing the indoor with two number 1.2mt long MS equal angle of sizes 50 mmX50mmX 6mm by one side grouted into the wall The indoor unit suspended from this angle support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on wall with two number 1.2mt long MS "C" channel of sizes 80mmX40mmX 6mm by one side grouted into the wall as per direction of EIC.(MS Anglel must be painted by 1 coat of RO primer and 2 Coat of enamel paint)
Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:-
Copper pipe 6.35mm dia, min. thickness 0.8m (Make : Rajco / Mandev) with 9mm thick nitrile insulation. (Accoflex/K-flex/Armasell)
Copper pipe 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Mandev) with 9mm thick nitrile insulation.( Accoflex/K-flex/Armasell)
Copper pipe 15.88mm dia, min. thickness 0.99mm (Make : Rajco / Mandev)with 9mm thick nitrile insulation( Accoflex/K-flex/Armasell).
Copper pipe 19.05mm dia, min. thickness 0.99mm(Make :Rajco / Mandev) with 9mm thick nitrile insulation. (Accoflex/K-flex/Armasell)
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 6 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Wrapping the copper pipe with insulation & electric cable by S/F 28 SWG Aluminimum sheet to make it weather & vermin proff.
6mm dia with 9mm thick nitrile insulation, 15.9mm dia with 9mm thick nitrile insulation & 4core 2.5Sqmm Copper cable.
9.5mm dia with 9mm thick nitrile insulation, 15.9mm dia with 9mm thick nitrile insulation & 6core 2.5Sqmm Copper cable.
9.5mm dia with 9mm thick nitrile insulation, 19.05mm dia with 9mm thick nitrile insulation & 6core 2.5Sqmm Copper cable.
Supply & laying drain Water piping work with 25 mm dia Schedule 40 PVC/ UPVC hard pipes (Finolex / Ashirbad / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation.
S&F flexible canvas connection for indoor to duct/ air terminal for
5.27KW indoor
7KW indoor
10.55KW indoor
13KW indoor
SITC of Powder Coated Al. Grill without VCD suitable size (Make:Systemair / Primier)
S & providing drop ceiling to cover the indoor units & supply air duct including the cost of 3mm thick ACP sheet as per manufacturer's specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (1.6mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (1.6 mm thick) and silicon sealent complete in all respect including making trap door arrangement as per direction of EIC. (Make:Aludecor/Pratapbond)
Wall cutting charges for drain pipe and copper pipe(Suction and discharge pipe)
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB2520 /Hensel) of size [250X200X100]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC.
S.I.T.C. of Crono time switch [Make - L&T Cat. No. 67DDT0]
S & F of 4 pole 25A DIN rail mounted Power contactor with 240V operating coil [ make L&T/ ABB/ Siemens/ Schneider].
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
Lyric International
Shinryo Suvidha Engineers India Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .