Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-Finance | L1 | Accepted-Finance Being lowest bidder.
Rates are negotiated | |
| 2 | L2₹3.4 L+₹50,000 (17.5%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹3.5 L+₹69,708 (24.5%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹5.2 L+₹2.4 L (82.5%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
12 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Jammu
Executive Engineer Mechanical Irrigation Division Canal Road Jammu
Providing installation testing and commissioning of new 150 KVA Voltage stabilizer along with allied electromechanical works at LIS Ismailpur
2021_IFC_115189_1
e-NIT No. MID/J/e-NIT/2020-21/95
Open Tender
Machineries/ Mechanical Engg Items
Lump-sum
30 days
Ismailpur Jammu
Please refer Tender documents.
7 documents required · 7 mandatory
₹200
Executive Engineer MID Jammu
₹6,000
Yes
03-02-2021
19 Feb 2021
2 Feb 2021
13 Feb 2021
2 Feb 2021
12 Feb 2021
4 Feb 2021
2 Feb 2021 - 12 Feb 2021
3 Feb 2021
180 days
Amount
Providing and fitting of on load changeover switch 160 A ( 4 pole) after extracting the damaged old one from 100 kva stablizer. Providing and fitting of 1 nos. voltmeter, 1 no. ampere meter with CTs and 7 nos. phase indicators along with internal wiring after dismantling electric panel of stabilizer and removing the old damaged ones to make the existing 100 KVA stabilizer fully functional. the job includes shifting of stabliser with chain pulley block/tripod to exit side to make space for replacing parts of 100 kva stabliser Make of onload changeover switch: Havells, L&T,HPL,Standard, ISI eq. Make of Amperemeter, Voltmeter: AE,VKE,RISHAB, ISI eq.
Dismantling of cable connections from LT terminals and from 250 KVA transformer and removing the 4 nos. burnt cables from transformer to LT terminals after getting the HT supply disconnected. Providing and installation of one no. LT Fuse link set consisting of minimum 40 mm MS angle, MS flat, drilling holes aluminum bus bars/L clamps, D type shackle insulators , nut bolts, fuse wire, drilling holes Clamps and fixing . Job also includes proper erection of MS angle frame either to be fixed on pole or properly embedded on ground with PCC. The job also include P/fitting 3 lengths of 300 Sqmm and one length of 240 Sqmm AL conductor cable aprx. 5 meter each , stripping the cable ends, P/F thimble by crimping tool and giving connections to transformer and LT fuse link set. The job includes cost of material, thimbles, insulators, bus bars, supporting angle arms, nut bolts, washers, clamps, insulation tape, , labour, transportation charges etc. fabrication and fixing of MS angle frame inside pump room made up of minimum 40 mm MS angle with cross arms for fixing the frame in wall with anchoring bolts /PCC duly fitted with wall of LIS suitable for fixing 300/400 Amp main switches. The job also includes making of 8” dia hole in the LIS wall and passing of existing main cables from the hole duly fitted with PVC/GI pipe of appox. 1 foot length. . The job also includes fixing of existing/ available 300A main switch on MS frame at suitable place and giving conections to it with existing incoming AL cables on one side and LT fuse set on other side after cutting dressing and thimbling and crimping of cable ends . The job includes cost of material, skilled labour, shifting, transportation, loading/unloading and installation charges. Job also includes dismantling of internal connections inside the pump room from old damaged main switches , old panel board , cutting of cross arms of old panel board and creating sufficient place for 150 kva stabliser. Extracting/cutting of damaged MS angle arms of panel board to remove it from pump room.
Dismantling old defunct 150 KVA voltage stabilizer extracting out detachable parts, draining of T-oil in a suitable container and other detachable material and removing the stabilizer to outside of pump room with the help of tripod, chain pulley block and manual labour. Shifting of stabilizer parts to roadside using tool tackles, crane and manual labour. Reassembling the stabilizer and then loading in mechanical transport and shifting to division store near canal road. The job includes shifting of other old defunct equipments like Change over switch, ampere meter, voltmeter, worn out cables etc. to the divisional store with the defunct voltage stabilizer. Again unloading the stabilizer and other material at divisional store using crane/manual labour.
M/S JAIMA ELECTRICAL CO -II
M/s AJP Electricals Private Limited
NACHIKETA TECHNOLOGY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .