Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.5 L+₹1.5 L (10.5%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹16.5 L+₹2.5 L (17.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR/ MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES UNDER THE AOR OF AGE B/R-I OF GE 881 EWS
2020_MES_406955_1
GE/PNH-72/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹32,000
Yes
23 Apr 2021
25 Dec 2020
28 Jan 2021
25 Dec 2020
25 Jan 2021
7 Jan 2021
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in Hard/dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5m but n. exc. 3.0m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Supply, laying , jointing and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, fixed as in repairs complete all as specified and directed. Make: Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
All as per Item No 7 above but size 3.5 core 95 sqmm complete all as specified and directed.
All as per Item No 7 above but size 3.5 core 70 sqmm complete all as specified and directed.
All as per Item No 7 above but size 3.5 core 50 sqmm complete all as specified and directed.
All as per Item No 7 above but size 3.5 core 35 sqmm complete all as specified and directed.
All as per Item No 7 above but size 3.5 core 25 sqmm complete all as specified and directed.
All as per Item No 7 above but size 4 core 16 sqmm complete all as specified and directed.
All as per Item No 7 above but size 4 core 10 Sqmm complete all as specified and directed.
All as per Item No 7 above but size 4 core 6 sqmm complete all as specified and directed.
S&F LT overhead lines on existing poles, clamping and stringing of XLPE insulated AB cbale 3 core 70 sqmm + 1 core 50 sqmm including terminating and jumpering to the existing source of supply including all jointing kits, nut, bolts etc including taking down ola cable/ conductor complete all as specified and directed.
S&F in repair Suspenssion clamp with eye hook suitable for Aerial Bunch cable complete all as specified and as directed.
Supplying, installation and errection in true vertical position steel tubular swaged welded pole, 9.0 metre long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, fixed as in repairs complete all as specified and directed. Make : QUALITY STEEL / SURJIT STEEL INDUSTRIES / SOHAN LAL & SONS / ANIL ENGG CORPORATION / ZAIN INDUSTRIES SRINAGAR / ADVANCE TUBE JAMMU Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
Supply, stringing, streaching and binding with insulator, ACSR conductor of adequate size (Weasel /ferret/Mink) on LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed. Make: ICC/NICCO/JAIPURIA/ALIND
Stringing only ACSR (aluminium conductor steel reinforced) Conductor including suitable binding wire for connecting the existing OH lines including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified & directed.
S&F in repair Cradle hexagonal , rectangular fabricated with GI wire 3.15 / 4 mm dia on existing OH line, complete all as specified and directed.
Supply, streaching and binding GI earth wire 4 mm dia on existing OH line, fixed as in repairs complete all as specified and directed
M&L in replacement for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F in repair Pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA
S&F in repair Disc insulator porcelain viterous,white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron wahsers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in repair Shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA
Stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx140mm clearance of hole 25.5 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work fixed as in repairs complete all as specified and directed.
S&F in repair Tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 80 mm bore, complete all as specified and directed. Make: Jindal Pipes / TATA / Prakash Surya
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) Type D-2 (using 40mm graded crushed stone aggregates) as in foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
Line Seperator made out of high quality PVC suitable for LT 1100 Volts, 4 Lane, OH aluminium conductor complete all as specified and as directed.
Line Seperator made out of high quality PVC suitable for LT 1100 Volts, 2 Lane OH aluminium conductor complete all as specified and as directed.
M&L for Painting of LT panel including preparation of old surfaces by scrapping old paint completely and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
M&L for Painting to steel tubular swaged/ RCC pole (9 mtr long) complete with including cross arm/clamps etc after preparation of surfaces and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
All as per item No-35 above but Two pole structure Steel/RCC, with cross arms, clamps, structure etc 11/ 1.1KV HT/ LT complete all as specified and directed.
All as per item No. 35 above but Four pole structure Steel/ RCC, with cross arms, clamps, structure,etc 11/1.1 KV HT/LT complete all as specified and directed. Notes for item No-35 to 37 : Qouted rates shall deemed to be inclusive of followings:- (a) Scraping out wornout old paint and making the surface smooth. (b) Writing the pole & feeder No. on each pole complete all as specified and directed.
Material & labour for spreading evenly stone aggregate of size 40 mm size in the Sub Stn area complete all as directed by Eng-in-Charge at site.
S&F in repair MCCB, 4 pole, 100 Amps, 415 volts with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed. Make: Havells Cat Part No IHLGNF0100# or equivalent in Legrand/ Schneider/ ABB/ SIEMENS/ L&T/ C&S Electric
S&F in repair MCCB, 4 pole, 160 Amps, 415 volts with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed. Make: Havells Cat Part No IHA13EBF0160# or equivalent in Legrand/ Schneider/ ABB/ SIEMENS/ L&T/ C&S Electric
S&F in repair MCCB, 4 pole, 200 Amps, 415 volts with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed. Make: Havells Cat Part No IHLLSEBF0200# or equivalent in Legrand/Schneider/ABB/SIEMENS/L&T/C&S Electric
S&F in repair MCCB, 4 pole, 250 Amps, 415 volts with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed. Make: Havells Cat Part No IHLLSEBF0250# or equivalent in Legrand/Schneider/ABB/SIEMENS/L&T/C&S Electric
S&F in repair MCCB, 4 pole, 400 Amps, 415 volts with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed. Make: Havells Cat Part No IHLLSEBF0400# or equivalent in Legrand/Schneider/ABB/SIEMENS/L&T/C&S Electric
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 400 Amp MCCB 35 KA 4 pole for incoming and 4 Nos stepped type Aluminium bus bars 200 Amp for looping & branch connection system .The chamber shall be duly powder coated. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55. The bus bar chamber shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate, front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron pedastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm, complete all as specified and directed.
All as per Item No 46 above but cable of size 10 Sqmm complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized iron pipe 15 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair Test point terminal block made of gun metal or phosphorous bronze of size 75x75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to GI pipe/ wall for protection of test point complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x62mm GI strip including taking down old unsv earth conductor, complete all as specified and directed.
S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawl plugs etc for conductor for roof and fixed on wall upto test point, complete all as specified and directed.
S&F in repair Rubber insulating mat of size 2mx1mx12mm thick, ISI marked, complete all as specified and directed.
Usha Engineering Co.
BINDRA ENGINEERS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .