Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 CrAccepted-AOC 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹39.7 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹40.7 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹40.7 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹43.3 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹43.3 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹46.3 CrRejected-Finance | ₹46.3 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹55.9 CrRejected-Finance ERODE 638 002 | ₹55.9 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹39.9 Cr
EMD Value
₹15 L
Closing Date
16 Jan 2023, 6:00 pmClosed
CHIEF ENGINEER (CG) GOA
CHIEF ENGINEER (CG) GOA
CONSTRUCTION OF SINGLE INLIVING ACCOMMODATION AND ALLIED FACILITIES FOR OFFICERS AT 1 75 ACRE LAND AT PALLURUTHY KOCHI
2022_MES_559872_1
82047/e8
Open Tender
Civil Works
720 days
KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) CG KOCHI
₹15 L
Yes
18 Apr 2023
26 Oct 2022
18 Jan 2023
26 Oct 2022
16 Jan 2023
2 Jan 2023
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD PATH, CULVERT AND HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (SECURITY WALL WITH GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (RAIN WATER HARVESTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (LIFTS/LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (AVIATION OBSTRUCTION LIGHT/ DG SET) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
PILE FOUNDATION: Boring of cast in situ pile of 800 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including providing and errecting equiment/plant suitable for under reamed piles and removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 400 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including providing and errecting equiment/plant suitable for under reamed piles and removal of bored materials to place out side MD land all as specified and directed.
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile (Note:- RCC shall be measured and paid from cut off level and rates quoted shall be inclusive of cutting & knocking of RCC lattaince concrete from cut off level)
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg (Note:- Reinforcement will be measured and paid for seperately under relavent items of this schedule)
Excavation over areas not exceeding 1.5m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavation over areas exceeding 1.5m deep but not exceeding 3m and getting out in soft/ loose soil complete all as specified and as directed.
Excavation over areas exceeding 3m deep but not exceeding 4.5m and getting out in soft/ loose soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
M&L for Cement Concrete in Foundation, Filling and mass concrete 1:4:8 type D2 using 40mm Graded aggregate
Formwork to sides of pile caps/ grade beams rough finished surface of concrete flat all as specified and as directed.
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10 mm dia and over for bored piles/pile cap/grade beam, of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCR/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as stirrups/helical for pile caps/ grade beams cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9mm dia or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs (Fe-500D).
Conducting Initial Load Test (Compression) up to maxmimum test load of 2.5 times the safe load capacity on single pile (800 mm dia) as specified in accordance with IS 2911 part-4 including preparation of pile head for testing, necessary excavation, jacks, kentledge, accessories, measuring devices, recording of results, labour, submission of test report etc. complete, but excluidng the cost of installation of pile (insallation of pile shall be paid seperately) etc.all complete as per the specification, drawing and as directed by the Engineer in charge for the following
Carrying out Initial Lateral Load Test on vertical (Initial/test) piles up to maxmimum test load of 2.0 times the safe lateral load capacity on single pile (800 mm dia) as specified in accordance with IS 2911 part-4 including all necessary arrangements such as jacks, measuring devices, etc. complete as required. (For this test if adjoining piles is used for drawing support for test then the arrangements shall be made to record deflection, submission of test report etc. of both the piles. However, testing both these piles will be considered as one test only. Providing and installing test piles measured separately)
Conducting Routine Load Test (Compression) on single working pile (800 mm dia) up to maxmimum test load of one and a half times the safe load capacity as specified in accordance with IS 2911 part-4 including the preparation of pilehead for testing, necessary excavation, providing all arrangements of loading and unloading in the form of kentledge or anchore piles, test equipments/accessories, jacks, labours, recording of results, submission of test report etc. but excluding the cost of job pile complete as per the specification, drawing and as directed in charge for the following
Carrying out Lateral Load Test on single working pile (800 mm dia) up to maxmimum test load of one and half times the safe load capacity as specified in accordance with IS 2911 part-4 including all necessary arrangements such as jacks, measuring devices, submission of test report etc. complete as required. (For this test two working piles will be considered as test piles. Arrangements shall be made to record deflection, etc. of both the piles. However, testing both these piles will be considered as one test only.
For Tension/Uplift test (Pull Out ) on vertical (initial/test) piles (800 mm dia) as per IS 2911 part-4 up to maxmimum test load of two times the safe load capacity as specified including all necessary arrangements such as jacks, supports, measuring devices, etc. complete as required. Arrangements shall be made to record uplift movement, submission of test report etc.( Providing and installing test piles measured separately
Carrying out low strain pile integrity test on 800 mm diameter pile including all arrangements for test, equipments/accessories, materials, labour, submission of test report etc but excluding the cost of installation of job pile (installation of pile shall be paid seperately as per relevent items)all complete as per specification and as directed by the engineer-in-charge.
Testing of piles (Initial load test for compression load, lateral load and uplift load) all as per IS 2911 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 400mm dia cast in situ pile. Note : Rate is inclusive for casting of 04 piles for above test. However, boring, concrete and steel shall be measured and paid under respective item all as specified and directed.
Testing of piles (Routine Load test) all as per IS for 400mm dia Cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note : Only compression load test shall be carried out for Routine Load test all as specified and directed.
INTERNAL WATER SUPPLY: Supply & fixing 15 mm dia Bib taps long body Jaguar make (CQT-CHR-23037UPRG ) with restrictor 2.5 LPM at 3 bar pressure or equevlent complete all as specified.
Supply & fixing 15 mm dia Jaguar make 2 way bib cock ( CQT-CHR-23041GD) or equevlent with flow restrictor 3.8 LPM at 3 bar prssure complete all as specified.
Supply & fixing 15mm dia wall mixer Jaguar make ( CQT-CHR-23273G) equevlent with provision for over head shower with 115 mm long bend pipe on upper side, connecting legs, wall flenges & flow ristrictor of 2.5 LPM at 3 bar pressure complete all as specified
Supply & fixing 15 mm dia Jaguar make Angular stop cock ( CQT-CHR-23053) or equevlent complete all as specified.
Supply & fixing Over head shower 100 mm dia jaguar make ( OHS-CHR-1989GA) single flow (ABS body chrome plated with grey face plate) with rubit cleaning system and flow restrictor 6.0 LPM at 3 bar pressure and with shower arm (SHA-CHR-477P) with flege complete all asspecified.
Supply & fixing Jaguar make health faucet ( ALD-CHR-583GA) (ABS Body) with 1 Meter Long PVC Tube & Wall Hook) & Flow resrictor 6.0 LPM at 3 bars pressure or equevlent complete all as specified.
Supply & fixing 15mm dia Brass CP Wash hand basin long shank pillar cock, flow restrictor of 2.5 LPM at 3 bar pressure complete all as specified .
Supply & fixing of pvc flexible pipe connections 600 mm long complete all as specified 15mm dia.
INTERNAL ELECTRIFICATION: S & F BEE 3 star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
Supply, install, testing and commissioning of factory made and tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties (Building main panel) INCOMINGS: (a) MCCB 415 Volts,160 Amp , rating 4 Pole microprocessor based (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 35 KA)- 1 Nos. (b) Digital multi function Panel Mounted Meter with all necessary CTs, PTs and instrument fuses and wiring OUTGOING: (a) MCCB 415 Volts, 63 Amp , rating 4 Pole microprocessor based (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 25 KA)- 12 Nos. (b) Internal wiring of panel with stranded copper cable of suitable size (c) LED phase indicating lamp(Set of three)-01 Nos (d) Stenceling of pannel board including marking of distribuitions
Supply, Installation, Testing and Commissioning of 1-Phase, 2-wire, 240V, Class 1.0 Smart Energy Meter, BIS marked IS-16444, at the rating of 5-30A suitable for Prepaid/Postpaid mode with Polycarbonate Meter Box. The Smart Meter shall support the following minimum basic features: Measurement of electrical energy parameters; Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. Meter shall have the ability to communicate with Head End System (HES) on RF Communication technology mentioned in IS16444 Part 1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM. RF network should use 865-867 MHz frequency band as permitted by WPC.
Supply, installing, testing & commissioning of Cloud-Hosted multiuser web-based software with following modules: (i) Head End System (HES): to acquire meter data automatically from DCUs and monitor parameters acquired from meters. (ii) Meter data management Modules : The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data. (a) 30min instantaneous data from all the meters for seven parameters - cumulative energy , Power, Current , Voltage, Power factor and frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand. (iii) Billing Module : The billing module would collect the data from the meter data management module, calculate billing determinant and make energy data / billing data available to admin and end user. There should be provision for entry of change in the tariff structure by the MES staff as decided time to time. (iv) Occupation and Vacation module: The system would support occupation/ vacation based on the unit categories. (v) Website: There would be a dedicated website for AGE/GE and BSO team to view all the data and information along with customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (Androi and iOS based) for admin use. (vi) Customer Module : The system would include a customer portal for the resident/occupants to log in and view their own energy/billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.
Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter(1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc.
RAIN WATER HARVESTING: S&F UPVC pipes of bore 150mm with fittings complete all as specified.
EXTERNAL WATER SUPPLY: M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
EXTERNAL ELECTRIFICATION: Supply, installation, testing & commissioning of cubic type, floor mounting totally enclosed outdoor weather proof powder coated CRCA sheet steel enclosure with provision for mounting 3 Nos resin cast indoor type three phase PT, provision for receiving 3 core 300 Sq mm 11 KV cable, provision for mounting HT TOD meter, test terminal blocks, necessary control cabling etc, including CT & PT of suitable capacity, DLMS trivecctor compatible HT TOD meter complete all as specified & directed
Supply and erect 2 pole structure on 11 meter PCC pole, anti-climbing device, PCC foundation & cross arms etc complete all as shown on drawings and as specified & directed by Engr in charge.
Design, Engineering Manufacturing, Erection, Testing & Commissioning Supply of 11KV Outdoor Compact Secondary Substation (CSS) rated 160KVA resin cast Transformer with HT side DV module RMU and Metering cubicle, and LV side complete all as specified and directed. The CSS includes the following items:- (a) (HT Switch Gear) Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switch gear complete with Vacuum circuit breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amps using XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded conductor, 11000 volts grade of size 3 core 95 sqmm (b) (Transformer) Supply and installation of copper wound transformer step down, indoorloutdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage within limit, all as per 19:2026 of capacity 160 KVA (c) (APFC Panel) Supply and install APFC panel with MPP-H capacitor of capacity 20 KVAR, 415 Volt, 50 Hz (d) Supply install test and commission LT Panel, indoor type, powder coated, dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 2.00 mm thick CRCA Sheet & MS angle iron section of 50X50X6mm frame, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natural flow of air. Suitable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands.
The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalized for each control gear with louvers and air vent gasket for natural flow of air and suitable to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable bus bar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on no hygroscopic, non-combustible, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm throughout the length of the TPN bus bar all as specified and directed by Engr in charge. Aluminium bus bar for 3 phase,440 volts, 50Hz, 4 wire system of rating 1000 Amps for phases and 500 Amps for Neutral Incoming:-( from transformer to main LT panel 320 Amps 433V 4P 50Hz 50KA Electrical Draw out type Air Circuit Breaker (ACB) (a) MCCB 320 Amp FP 50 KA-01 (Incoming) Metering Unit- (a) RYB Indications (LED Type) - 1 sets (b) Digital Multi-function meter - 01 No. (c)CTS-320/5A, CL-1,15 VA-1 set Outgoing (a) MCCB 200 Amp FP 36 KA-01 (b) MCCB 160 Amp FP 36 KA-02 (c) MCCB 125 Amp FP 36 KA-01 (d) MCCB 32 Amp FP 36 KA-01
Supply,install,test and commision LT Panel,indoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 2.00 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suiable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. -(location of the panel: LTP No 1 Power house) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 500 Amps for phases and 250 Amps for Neutral.
INCOMINGS (a) MCCB 415 Volts, 250 Amp , rating 4 Pole microprocessor based (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 35 KA)- 1 Nos. (b) Digital multi function Panel Mounted Meter with all necessary CTs, PTs and instrument fuses and wiring OUTGOING (a) MCCB 415 Volts, 200 Amp , rating 4 Pole microprocessor based (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 25 KA)- 1 Nos. (b) MCCB 415 Volts,160 Amp , rating 4 Pole (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 35 KA- 2 Nos (c) MCCB 415 Volts, 63 Amp , rating 4 Pole microprocessor based (triple pole and neutral), Thermal Magnetic release (Service Breaking Capacity 25 KA)- 1 Nos. (d) Internal wiring of panel with stranded copper cable of suitable size (e) LED phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
All as per item No.15.43 above but with the following fixtures:- location of the panel: LTP No 2) DG panel Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 125Amps for Neutral. INCOMINGS: (a)Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps- 1 Nos. (b) Digital multi function Panel Mounted Meter with all necessary CTs, PTs and instrument fuses and wiring OUTGOING: (a) MCB 415 Volts, 32 Amp , rating 3 Pole (triple pole) - 2 Nos (For Water supply pumps) Nos-2 (b) MCCB 415 Volts, 32 Amp , rating 4 Pole - 3 Nos (For 02 Nos for lift and 01 No for Fire pumps) (c) MCB TPN, 32 Amp -01 Nos (Security light & Common Area light) (d) Timer -01 No with contactor (e) LED phase indicating lamp-01 Set of three (f) Stenceling of pannel board including marking of distribuitions (g) DOL starter suitable for 7.5 HP pump.
Supply and spread LT Rubber mat of 1 mtr x 2 mtr x 19 mm
Supply and fix street light fitting pressure die cast aluminium housing with heat resistant toughened glass IP 66 protection of 45 watt, 230 V, LED street light fitting complete with LED lights, inbuilt erlectronic driver, minimum 10 KV surge protection, nmumber of LED 44 with clear acrylic cover accessories pre wired and fixing accessories ie nut bolt washers, Flat iron strips, Gi pipe etc. . complete all as specified. Make: Havells or equivalent specification in CELLS/Philips/Wipro.
Supply and fixing post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25 watts 230 Volt Make: Havells or equivalent specification in CELLS/Philips/Wipro.
FIRE FIGHTING: Supply,install,test and commision LT feeder pillar box type panel,outdoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suitable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. (Electrical driven ,jockey pump & Diesel Engine driven pump) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral.
INCOMINGS: MCCB 4 pole, 415 Volts, 200 Amps, breaking capacity 35 KA- 01 No. Metering Unit:- R Y B Indications (LED Type) - 1 sets Digital Multi function meter - 01 No. CT's - 200/5A, CL-1,15 VA - 1 set OUTGOING (a) MCCB 4 pole,415volts 160 Amps "D" curve 35 KA - 02 No. (b) MCB TPN 32 Amps "D" curve 10 KA - 2 No. (c) Star delta starter for 65 HP motor- 01 No. (d) Star delta starter for 10 HP motor- 01 No.
Supply, connect, joint and lay MS pipe (ERW) heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply, connect, joint and lay MS pipe (ERW) heavy duty ISI marked with all fittings of size 80 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply erection testing and commissioning of Gun metal Air release valve 50mm dia complete.
Supply, installation, testing and commissioning of Analog addressable type active Loop Repeater (Loop power/External power) fire terminal with inbuilt turbo isolator, Backlit LCD display 6 X 40 characters display, having controls for reset, mute, accept, silence alarms and self test with programmable free keys and duly approved by EN54/LPCB/VDS/FM Make:- SIEMENS/NOTIFIER/BOSCH
Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
S&F wall mounted LED emergency Exit signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
M&L for address isolator module RE 71 MI (Make Ravel or equivalent)
S&F fire extinguisher dry chemical powder (ABC) type (IS 15683) of capacity 6 kg complete with installation brackets all as specified & directed.
S&F fire extinguisher CO2 (Light weight squeeze grip type) (IS 15683) of capacity 4.5 kg complete with installation brackets all as specified & directed.
AVIATION OBSTRUCTION LIGHT: Supply and fix aviation obstruction light integral aviation light comprising of aluminmium housing with poly carbonate enclosure 302 nod LED . Make Bajaj Cat No. BGAV 302 LED/equivalent.
S&F timer switch and MCB SPN, 230 V, 10 Amp enclosed in a metal enclosure.
DG SET: Supply and install Static silent Diesel Engine with accoustic enclosure, capable of delivering 24 Kw (30 KVA), water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frame and complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestos rope protection completye and shall be suitable for conditions prevailed at Kochi.(Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at the area to be installed). The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:- (i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, six cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 24Kw(30 KVA) at outdoor atmospheric conditions at palluruthy,kochi (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with tacho meter, lub oil temperature, pressure gauge and frequency meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc
(ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 24 Kw (30 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine. (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing performance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank. (v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice.
(vi) AMF CONTROL PANEL:- factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40x40x5 mmand 2 mm thick MS CRCA Sheet, front opening type, protection class IP-54, duly powder coated, copper bus bar with coloured PVC sleeves and of suitable rating for four poles mounted on suitable porcelain insulators at recommended intervals, with all standard switch gear and protection, internal wiring with adequate size and rating PVC insulated multistranded copper conductor cables etc. and also consisting the following: Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 300 Amps for phases and 150 Amps for Neutral. Incoming:- (a) MCCB 4 pole,415 Volts, 200 Amps, breaking capacity 36KA- 02 Nos. Metering Unit and other accessories :- (a) R Y B Indications (LED Type) - 1 set. (b) Indicator for on/off GEN/MAIN supply- 2 Nos. (c) Digital Multi function meter - 01 No. (d) CT's - 100/5A, CL-1,15 VA - 1 set (e) 3 pole line Contactorwith AC coil, 100 Amps- 2 Nos. (f) All standard relays, circuits and protection required for automatic operation of DG set. (g) Charger for recharging the battery and armoured copper cable of suitable rating from battery charger to the engine- one job. Outgoing:- (a) MCCB 4 pole,415 Volts, 125 Amps, breaking capacity 25 KA- 02 Nos.(one spare)
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth wire 4 mm dia. by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete.
HOT WATER SUPPLY:- Supply and fix electric water heater storage type steel body with cooper inner tank and heating element upto 2 KW capacity 25 litre, BEE rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed.
COOLING APPLIANCES:- Supply, fixing, testing and commissioning of water cooler with inbuilt purifier HIMA 7 NHC, dispenscing capacity 125 ltrs/hr and storage tank capacity 40 Ltrs normal, 40 Ltrs cold, single phase 230V AC power supply with all connecting accessories complete all as specified and directed.
Supplyand fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desighned for input variation 170V with put put valtage stabilised at 230V with accuracy of ± 2.5% and of capacity 3 KVA all as specified and directed.
SECURITY WALL :- S&F stainless steel letters in hindi & english language 150 to 250mm height, 100 to 150mm wide, 25 to 35mm thickness polished to glossy finish made out of stainless steel plates including necessary fixing arrangment to walls including welding complete all as directed.
LIFT:- Outsourcing of services for manning and operation of Electrically Operated Passenger Lift of Capacity 544 KGs, 08 Passangers 02 Nos by employing qualified operator in two shifts (one operator in each shift ie, two shifts in a day to operate, rescue in case of failure/emergency) including Sundays and Holidays, including cleaning and upkeeping of equipments nad sorroundings etc. complete all as specified and directed by Engr in charge. For First year (11 Months commencing from the next day of date of completion of work).
All as per item No.15.73 here in before but for Second year (11 Months commencing from the next day of date of completion of First year. (BOQ Item No 15.73 above))
NOTE FOR ITEM NO 15.73 & 15.74:- (i) One qualified lift operator per shift of 08 Hrs as mentioned shall be deployed including sundays and holidays (with necessary reliever) according to duty roaster to be submitted by contractor before commencement of month. The rate quoted shall be deemed to be inclusive of wages of reliever. (ii) The contractor shall employ lift operator having recognised qualification with adequate experience in similar nature of work.
All as per item No.15.76 here in before but for Second year (12 Months commencing from the next day of date of completion of First year (ie, BOQ Item No 15.76 above))
All as per item No. 15.76 here in before but for Third year (12 Months commencing from the next day of date of completion of Second year (ie, BOQ Item No 15.77 above))
NOTE FOR ITEM NO 15.76 to 15.78:- (i) Comprehensive maintenance of lifts shall start from after expiry of defect liability period. (ii) Consumble items, cabin LED lamp of existing rating, minor spares costing less than Rs. 2000.00 each etc are deemed to be included in rate quoted. (iii) Major spares required for maint of lift shall be measured and separately. (iv) Cleaning of car, shaft well, lift control room, replacement of ground mat, etc shall be included in over all rate quoted. (v) Replacement of all ceiling lights, including replacement of ceiling if required for fixing lights etc as directed by Engr in charge shall be included in the over all rate quoted. (vi) Functioning of all emergency telephone service inside the car and control room including replacement of telephone if required shall be included in the over all rate quoted.
A2Z ENGINEERS AND PILE FOUNDATIONS
Mecone Construction Contractors
Agarwal Jagdish Construction Company Pvt. Ltd.
S.S.NATARAJAN AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid