Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAdmitted-Finance | ₹2.6 L | L1 | Admitted-Finance |
| 2 | L2₹3.4 L+₹73,750 (28.1%)Admitted-Finance | ₹3.4 L+₹73,750 (28.1%) | L2 | Admitted-Finance |
| 3 | L3₹3.5 L+₹90,270 (34.4%)Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | ₹3.5 L+₹90,270 (34.4%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | - | - | Not Admitted-Fee/PreQual/Technical Others-FDR not Submitted |
| Sl No | Description | Qty | Unit | M G Traders and Engineers L3 | Shiva Buildtech L1 | Gupta Brothers L2 |
|---|---|---|---|---|---|---|
| 1.01 | Repair/Renovation of HT rotor resistance control system of Pump Set No.1 at Sarita Vihar SPS by carrying out following works: -
Dismantling of the Automation panel starter & Automatic rotor controller, removing of cable connection, logic control unit, sensing lead from sump by skilled technical person at site. | 1 | Job | 25,000 ₹29,500 | 32,500 ₹38,350 | 20,000 ₹23,600 Lowest |
| 1.02 | Repairing of HT Automatic rotor resistance unit & panel unit for operation of 500 HP 3.3 KV HT motor pump set By replacing following items. Power Contactor: 3 Nos. 400 A 220 Volt; 1 No. CT overload relay, star delta timer- 3 Nos.; Auxiliary relay - 6 Nos. 24 VAC; 1 no. auto manual selector switch with keys, 1 no. Volt meter with VSS, 1 no. ampere meter with ASS, 3 Nos CT 400/5,1 No. Buzzer Alarm with reset button, 1 No. Phase failure relay with phase sequence with high low voltage, Control wiring- 4.0 Sqmm; power wiring 120 sqmm; HT fuses and spreader terminal, Control MCB 6 Amp. - 6 Nos; TP MCB 16 Amp. - 1 No. and PVC insulated single core flexible copper cable 120 Sq. mm as per requirement.
Make: L&T/ Minelec/ Finolex/ Havells/ HPL/ Any DJB approved make. | 1 | Job | 2,15,000 ₹2,53,700 | 1,35,000 ₹1,59,300 Lowest | 2,10,000 ₹2,47,800 |
| 1.03 | Re- fitting & installation of system on site & making Cable connection with thimble /tapping etc. | 1 | Job | 28,000 ₹33,040 | 30,000 ₹35,400 | 25,000 ₹29,500 Lowest |
| 1.04 | Testing & commissioning of panel and other accessories with relevant IS as follows:- check equipment specification, continity and earthing, meggaring of all equipment’s for phase to phase , neutral to earth and phase to earth , all functional tests, checking for all tughtness of nut and bolts , allignment of doors etc , interlocking test as per site requirement. | 1 | Jobs | 31,000 ₹36,580 | 25,000 ₹29,500 Lowest | 30,000 ₹35,400 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
1 Jul 2026, 3:00 pmClosed
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Repair Renovation of HT rotor resistance control system of Pump Set No.1 at Sarita Vihar SPS
2026_DJB_294373_1
N.I.T. No. 05 2026 27
Open Tender
Miscellaneous Works
Works
30 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹7,000
4 Aug 2026
25 Jun 2026
1 Jul 2026
25 Jun 2026
1 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Repair/Renovation of HT rotor resistance control system of Pump Set No.1 at Sarita Vihar SPS by carrying out following works: -
Dismantling of the Automation panel starter & Automatic rotor controller, removing of cable connection, logic control unit, sensing lead from sump by skilled technical person at site. | 1 | Job | 80 | ₹80 |
| 1.02 | Repairing of HT Automatic rotor resistance unit & panel unit for operation of 500 HP 3.3 KV HT motor pump set By replacing following items. Power Contactor: 3 Nos. 400 A 220 Volt; 1 No. CT overload relay, star delta timer- 3 Nos.; Auxiliary relay - 6 Nos. 24 VAC; 1 no. auto manual selector switch with keys, 1 no. Volt meter with VSS, 1 no. ampere meter with ASS, 3 Nos CT 400/5,1 No. Buzzer Alarm with reset button, 1 No. Phase failure relay with phase sequence with high low voltage, Control wiring- 4.0 Sqmm; power wiring 120 sqmm; HT fuses and spreader terminal, Control MCB 6 Amp. - 6 Nos; TP MCB 16 Amp. - 1 No. and PVC insulated single core flexible copper cable 120 Sq. mm as per requirement.
Make: L&T/ Minelec/ Finolex/ Havells/ HPL/ Any DJB approved make. | 1 | Job | 80 | ₹80 |
| 1.03 | Re- fitting & installation of system on site & making Cable connection with thimble /tapping etc. | 1 | Job | 80 | ₹80 |
| 1.04 | Testing & commissioning of panel and other accessories with relevant IS as follows:- check equipment specification, continity and earthing, meggaring of all equipment’s for phase to phase , neutral to earth and phase to earth , all functional tests, checking for all tughtness of nut and bolts , allignment of doors etc , interlocking test as per site requirement. | 1 | Jobs | 80 | ₹80 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_391359.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .