Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹19.4 L+₹2.8 L (16.7%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹19.6 L+₹3.0 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹23.9 L+₹7.2 L (43.5%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹24.3 L+₹7.6 L (45.7%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) JORHAT
GE (AF) JORHAT PIN-785005
PROVN OF EXTENDING ELECTRIC POWER FROM OLD DETT TO NEW DETT BUILDING AT ALG TUTING AND MECHUKA UNDER GE AF JORHAT.
2021_MES_493697_2
8932/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹33,000
Yes
18 Feb 2022
13 Jan 2022
29 Jan 2022
13 Jan 2022
27 Jan 2022
20 Jan 2022
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50 m and deposting where directed at a level n .exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand Cushioning in trenches for protection of UG Cables of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 18cm thickness, complete all as specified and directed. .
Supply, laying & testing 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm complete all as specified and directed.
Supply and fixing wall mounted bus bar chamber current rating 63 amps 4 way type suitable for 415 volt 50 Hz AC supply complete making all incoming and outgoing connections complete all as specified and directed. Make -Havells cat No.IHBC006304 or its equivelent in L&T / Legrad as approved by GE.
Supply and fixing Single Phase Electric Energy meter LCD display 230 volts current rating 05 to 30 Amp 50 Hz complete all as specified and directed.
Supply, laying & testing 2 core XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm complete all as specified and directed.
Supply & laying Sub-Class B brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and directed.
M & L for point wiring with 1.5 sqmm FRLS grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC casing and capping (not less than 20 mm wide) complete with all accessories including PVC board / box of suitable size for mounting of switches, sockets, regulators, etc including 1.5 sq mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as earthing continuity conductor by maintaining the colour code for one light point controlled by one way switch complete all as specified and directed.
One light point controlled by one way switch complete all as specified and directed.
One 5 amps socket point on independent board switch, complete all as specified and directed.
All as per Ser item No. 10 here-in-before but with 2.5 sqmm FRLS copper conductor cable and 2.5 sqmm as earth continuity conductor for 15 amps socket outlet on independent board complete all as specified and directed.
S & F modular PVC Box 1/2 module, complete all as specified and directed.
S & F modular PVC Box 3 module, complete all as specified and directed.
S & F modular switch one way 6 Amps, complete all as specified and directed.
S & F modular switch one way 16 Amps, complete all as specified and directed.
S & F modular socket 5 pin 6 Amps, complete all as specified and directed.
S & F modular socket 5 pin 16 Amps, complete all as specified and directed.
S & F Modular white cover plate with frame, 1 Module complete all as specified and directed.
S & F Modular white cover plate with frame, 3 Module complete all as specified and directed.
S & F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
S & F LED bulb, 10 watt complete all as specified and directed.
S & F SP&N DBs, double door, 240 volt, 8 way complete all as specified and directed.
S & F SP&N DBs, double door, 240 volt, 4 way complete all as specified and directed .
Supply and drawing submain wiring with two runs of single core 1.5 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 1.5 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete all as specified and directed. NOTE:- Two run of single core cable and one run earth wire will be measured as one Rm of sub main wiring.
Supply and drawing submain wiring with two runs of single core 2.5 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 2.5 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete all as specified and directed. NOTE:- Two run of single core cable and one run earth wire will be measured as one Rm of sub main wiring.
Supply and drawing submain wiring with two runs of single core 10 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and caping and all necessary fittings including 10 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete all as specified and directed. NOTE:- Two run of single core cable and one run earth wire will be measured as one Rm of sub main wiring.
S & F Miniature circuit breaker (MCB) 240V, 10 KA ' C' curve of following Amp ratings, poles and current carrying capacity fixed in the MCB DB with connection testing and commitioning complete all as specified and directed.
SP 6 to 32 Amps
SPN 32 Amps
Supply & Fixing commissionig and testing voltage stabilizer copper covered for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 250V with out put voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 10 KVA complete all as specified and directed.
M/S RK SAHA AND CO
M/S DILIP GOSWAMI
M/S D J ENTERPRISE
M/S SANTOSHI TRADERS
jawaharlal jaiswal and co
THE SUPPLY AGENCY
M/S Deep Construction
Bidder Name
M/S RK SAHA AND CO
M/S D J ENTERPRISE
THE SUPPLY AGENCY
M/S Deep Construction
M/S DHAR AND DHAR
jawaharlal jaiswal and co
M/S SANTOSHI TRADERS
M/S DILIP GOSWAMI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .