Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.6 LAccepted-AOC | 1 | Accepted-AOC L-1 | |
| 2 | 2₹43.1 L+₹55,287.40 (1.30%)Rejected-Finance 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹43.3 L+₹70,785.50 (1.66%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹44.0 L+₹1.4 L (3.25%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹44.4 L+₹1.9 L (4.36%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
PROVN OF GATE (GEN BIPIN RAWAT DWAR) AT CARRIAPPA ROAD AND OTHER SANCTIONED WORKS UNDER GE (EAST) LUCKNOW
2022_MES_561488_1
GE/E/LKO/T-42 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹96,000
Yes
15 Dec 2022
4 Nov 2022
8 Dec 2022
4 Nov 2022
7 Dec 2022
19 Nov 2022
Amount
Taking down chowkat or frame with shutters area exc 1.5 sqm but not exc 4 sqm each (without taking off the shutters from the frame) including iron mongery and cutting holes for hold fasts & making good complete all as specified & directed.
S&F powder coated aluminium frame for doors,windows, ventilators with one or more rebates including jointing cleats for fixing complete all as specified and directed
S&F 100mm butt hinges extruded brass with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified & directed.
S&F 150 mm long brass barrel tower bolts with barrel of extruded section complete all as specified & directed.
S&F of 12 mm thick toughened glass with necessary matching including all fittings and fixture and pivot at top fancy type glass handle of size not less than 300 mm on both sides with colour glass shutter top and bottom aluminium rail with suitable locking arrangement and all necessary fittings including ozen glass door spring etc complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the premises complete all as specified & directed.
M&L exterior tile 30 cm x 30 cm x 25 cm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including 20 mm thick screed bed in CM 1:6 complete all as specified & directed.
S&F glazed ceramic coloured tiles 7mm thick 600 x 300mm of size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade etc over and including 10 mm thick rendering in CM 1:4 complete all as specified & directed.
S&F solid PVC wall lining, consisiting of 5mm thick panel with wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and directed
S&F 5mm thick PVC sheet fillets of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed
S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm diameter GI (upto1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60mm long including 12 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish etc complete all as specifed and directed.
Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar etc complete all as specified & directed.
Surface dressing not exc 15 cm deep in soft/loose soil complete all as specified & directed.
Excavating in trenches, not exc 1.5 m wide and not exc1.5 m in depth for laying of cables, pipes, foundation etc. and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified & directed.
Excavation in trenches exc 1.5m wide but not exc 3.0 m depth for foundation etc. or for shafts, wells, cesspits, manholes, etc. not exc 10 sqm on plan and not exc 1.5m depth & getting cut in soft/loose soil complete all as specified & directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified & directed.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point etc complete all as specified & directed.
Removing excavated material not exc 100 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for 75mm thick plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub-floors, sub-bases etc complete all as specified & directed.
S&F mild steel rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc. complete all as specified & directed.
M&L for mild steel framed structural work as in doors or gates of angle or ther section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing of Fe-410-W (Gde E- 250) Quality A complete all as specified & directed.
M&L for preparation of new surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide primer complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings etc complete all as specified & directed.
S&F coloured pre-painted GALVALUME aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strngth of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including necessary washers etc complete all as specified & directed.
M&L brick work with old size fly ash bricks, straight or curved on plan exc 6 meter mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling or mass concrete etc complete all as specpfied and directed.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendeing in CM 1:3 on concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and directed.
M&L for RCC design mix (M-25) using 20 mm graded stone aggregate for foundation footings , plinth beams, bases for columns up to GL etc complete all as specified & directed. Note:- Reinforement shall be measured and paid seperately under relevent item.
M&L for RCC design mix (M-25) using 20 mm graded stone aggregate for column above GL, lintel beam, chajjas, roof beam and slab or similar suspended work etc complete all as specified & directed. Note:- Reinforement shall be measured and paid seperately under relevent item.
M&L for TMT bars of 10mm dia and over cut to length, bent to shape required, including cranking and bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified & directed.
M&L for TMT bars of 6mm to 8mm dia cut to length, bent to shape required including cranking and bending and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L for TMT bars of 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for form work to flat, rough finished surface of side of concrete foundation, footing, bases of columns , plinth beams or similar work including any types of supports/scaffolding etc complete all as specified & directed.
M&L for form work to polygonal, rough finished surface of sides of concrete of columns above ground level, post, struits, piers, columns and stenchions , suspended roof slab and roof beams or similar work including any type of supports/scaffolding etc complete all as specified & directed.
M&L for form work to edges and soffits to arches, rough finished surfcaes of concrete, suspended roof slab and roof beams or similar work including any type of supports/scaffolding etc complete all as specified & directed.
M&L for form work to sides and soffits to domes, vaults, shell roofs and arch ribs, rough finished surface of concrete covered in one plain or similar work including any type of supports/scaffolding etc complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying 3 mm thick wall care putty complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified & directed.
S&F 25-30mm thick dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size area exc. 0.25 sqm but not exc 0.5 sqm fixed with and including on number SS clamps (grade -202) of flat 30 mm x 2mm , 150 mm long made to shape in each slab making V groove at top and bottom of stone and drilling hole for hold fasterner, polishing dholpur stone dust 1:1 complete all as specified & directed.
S&F stainless steel/CP Brass letter or figure (not less than 2.5mm thick) (Block, Roman Italic or Indian) size 300 mm long x 50 mm width) etc including fixing complete all as specified and directed.
M&L for 20 mm thick granite table rubbed and polished as required fixed on pilars over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L hardcore of broken stone or boulders of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified & directed.
M&L machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness , M-40 grade with grey cement and pigment etc complete all as specified & directed.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness , M-35 grade with grey cement and pigment etc complete all as specified & directed.
M&L sand filling under floors or in foundation including watering and consolidation etc complete all as specified & directed.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified & directed. (Note:-each line wire to be measured)
M&L for brick work with sub class B old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 12.5 mm graded crushed stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
Demolition of brick or stone/boulder masonry built in cement mortar complete all as specified & directed.
S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F concertina coil 45cm dia made of galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
S&F three core 2.5 sqmm copper cable including PVC Conduit medium grade, ISI marked not less than 20 mm dia along with conduit fixing accessories complete all as specified and directed.
M&L for writting name in LED lighting system(GEN BIPIN RAWAT DWAR) with minimum size 300 x 50 mm in glass material IP-66 of complete all as specified and directed.
Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3 and making good, cutting not exc 20 cm girth complete all as specified and directed.
S&F uniflood integral flood light with driver inside a PDC housing, highly efficient LED Flood light 110 W IP 66, 5700K Efficiency of >120 Lm/Watts , CRI > 70, THD<10%, PF > 0.95. Surge protection 4KV with built-in driver, short circuit, low & high voltage protection, Reverse Polarity & open load protection and Auto restart, external 10 KV Surge protection, Input operating Voltage Range 140-270 V AC complete all as specified and directed.
S&F master LED spot lighter , 7-15W including holder and driver complete all as specified and directed.
S&F LED post top lantern fitting made in die-cast aluminium, glare free indirect lighting distribution, affordable and stylish, robust and limited upward light component for 360° indirect light 45W, 2700K IP 65 protection complete all as specified and directed.
S&F RGBW surface mounted Narrow/Medium beam Projector/ Floodlight luminaire suitable for outdoor applications of Facade Lighting with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 1440-1510 Lm. Luminaire having DMX 512 control protocol capable of producing 16.7 million colour options. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/60⁰/30⁰x50⁰. Power consumption should be between 33W to 38W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements complete all as specified and directed. Make:- Bajaj ,Cat Part No. :- BA SP IN1 S 36W RGBW B1 or equivalent as approved by GE .
Supply of DMX Splitter cum Booster ,Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged aluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 2 output ports with 3/5-pin terminal sockets , each port should be optically isolated , protection rating IP20 including connection complete all as specified and directed.
S&F DMX Controller System with Standalone interfaces with 2*512DMX channels, future upgradation provision up to 4 DMX universe Port with new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management) Intuitive backlit keyboard with 10 presets.Standalone DMX IN triggers: External triggers: 10 buttons for direct access,2 buttons to change scene,+ 1 button to change zone. 16 dry contact trigger ports via 20-Pin IDC Socket. Internal calendar, Backup of the internal clock, 3weeks without power, Memory card microSD card, 32GB max, Input power voltage: 5-5.5V DC 0.6A with power adaopter . Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons: iPhone/iPad/Android remote and programming apps. Temperature: 0 to +50 C°, DMX Compatibility: 8 and 16 bit DMX fixtures, System Compatibility: Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X. Make: Nicolaudie/Pharos/Osram ECUE/Philips iColor (10.6 and +), Linux or equivalent as approved by GE. Make: Nicolaudie: SLESA-U11 or equivalent as approved by GE .
S&F MCB DB TPN (double door) 4 Ways, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
S&F MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
S&F MCB, single pole, 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA complete all as specified and directed.
S&F MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10 KA complete all as specified and directed.
S&F MCB three pole & neutral 415 volts 100 Amps rupturing capacity 25 KA complete all as specified and directed.
Material and Labour for Submain wiring 2 x 6 Sqmm of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings complete all as specified and directed.
M&L for out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory fabricated suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted complete all as specified and directed and omprising of the following:- a) TPN, Aluminium bus bar 400 Amps insulated with colour coated heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, Four Pole – 1 No c) LED Indicator lamp RYB - 01 set of three. d) Necessary excavation, earth work, PCC lean type D2 (1:4:8 ) and PCC type C2 (1:3:6 ) platform etc all as required. (e) Astronomical Solar timer half Kilowatt controling of light system .
Supplying and laying 1100 Volt grade heavy duty PVC cable with PVC insulated aluminium conductor served with inner sheathing pf PVC tape armoured XLPE cable with galvanized steel wire all PVC sheathed 16 sqmm 3 core nominal cross sectional area for service connection complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
M/S S S A ASSOCIATES
QUALITY CONSTRUCTIONS CO
ANIL CONSTRUCTION
M/S SWATI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .