Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC NA | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.1 Cr+₹3.8 L (3.71%)Rejected-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L2 | Rejected-AOC Rejected |
Tender Value
₹85.7 L
EMD Value
₹1.7 L
Closing Date
30 Sept 2021, 5:00 pmClosed
EE PHED No.1 Rohtak
Jhajjar Road Rohtak
Recall Kalanaur Town Under NCRPB Construction Of Screening Chamber Collecting Tank Pump Chamber Boundary Wall And Supply Erection Testing And Commissioning Of Non Clog Sewage Pumping Sets
2021_HRY_189406_1
DNIT Approved vide SE No. 1876 dt. 05.08.2021
Open Tender
Civil Works
Works
180 days
Kalanaur Town
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1.7 L
Yes
9 Nov 2021
22 Sept 2021
1 Oct 2021
22 Sept 2021
30 Sept 2021
22 Sept 2021
Amount
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCS sheet dulyStouted with suitable angle iron frame work and completely powder coated of approximate size 500 x 1200 mm and 400 mm deep having following accessories :-(At IPS Railway Line Par) 1. Incomer Switch 100 Amp 2. Aluminum bus bar chamber of 100 Amp. Capacity 3.Volt Meter 100x100 mm range 0 to 500 V (AE/KAPPA/L&T) 4. Indicating Lamp-One set
(A) Supply, Erection,testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items. For Raw Sewage water Pump set 700 LPM 20 Mtrs Head 2 Nos. a) Main switch 100 Amp 2 No. (L&T Siemens,ABB) b) Volt meter 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) C) Amp meter 100x100mm range 0 to 100 Amp 2 No. (AE/KAPPA/L&T) D) CT 100/3 Nos. (AE/KAPPA/L&T) E) VSS 1 No. & ASS 2 No. each of approved make F) SPP 2 No. of approved make g) Motor starter, Star delta 2 No. for 700 LPM 20 Mtr. H) Capacity KVAR as per site requirement 2 No. I) Indicating Lamp - One Set J) Change Over switch 100 Amp = 2 NO.
Railway Crossing (Rohtak-Bhiwani Section)
Probe Rader survay to check any underground obstruction finalizinfg the alignment complete.
A) Rate for items based on Haryana Schedule of Rates 2021
Boring/excavation including pit making at entry and exist point to the precise dimensions for the launch of the specialized auger boring machine in rock/bolders any underground utility like foundation, water supply line coming in alingnment or other underground obstruction under Railway tracks Rohtak-Bhiwani section suitable for M.S. casing pipe of following sizes complete in all respect using laser technique to ensure Horizontal boring including caution & sing board For 300mm i/d 5 mm thick M.S. Casing pipe
Coating of 300 mm i/d MS pipe outer and inner surface of casinbg pipe with high build epoxy paint as per RDSO specification No.n M&C/PCN III 88 to a dry firm thickness 2500mm micron for protection complete. 300 mm i/d
Laying/exacavation including covering Designm mix concrete M-25 by cutting and cover, method/excavation to the precise dimensions in normal 6 oil condition but not in Rcold Bolders normal,/ any underground utility like foundation, water supply line coming in alignment or other underground Obstruction under Railway Track Rohtak-Bhiwani Section suitable iron M.S. casing pipe of Following sizes complete in all respect using cutting S cover method technique For 300 mm i/d
Providing and inserting of M.S. casing pipe Fe-3300 grade fabricated as pet IS : 3589 of 991 from steel plants confirming to IS : 2062 & IS 1216/98 of size 300mm i/d including cutting. Beveling grid lining & radio Graphically welding of pipe as per IS -1182 complete in all respect incl. carriage to site of work & testing. For 300 mm i/d
Cleaning of surface 300mm i/d MS pipe ( casing pipe and carrier pipe) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating/high build epoxy paint/polythene tap system complete in all respect For 300 mm i/d
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS : 5382-1985 (excluding special accessories) complete including all material,labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/W to be measureed and paid separately. Pipe supplied by Department. For 150 mm i/d
Providing and fixing HDPE spacer at a distance of 2 Meters apart to avoid contract of casing pipe and carrier pipe complete in all respect For 150mm i/d M.S Pipe
A) Rate for items based on Haryana Schedule of Rates 2021
Prov. & Design mix concrete M-25 to plug & fill the space between casing pipe and carrier including cost of pumping etc. complete in all respect as per approved NIT 150mm i/d
Bidder Name
Amount
Surinder Singh Hooda(GSTN-06AABPH9599L2Z1)
Sh. Ashok Kumar Sindhu(GSTN-NA)
Surinder Singh Hooda
Surinder Singh Hooda
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .