Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.9 L+₹90,896 (11.4%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-AOC L2 | |
| 3 | L3₹9.2 L+₹1.2 L (15.2%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
Closing Date
8 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I TALBEHAT
LAKE VIEW CAMP MIL STN TALBEHAT 284125
PROVN OF CERTAIN MINOR, REVENUE AND SRW WORKS AT MIL STN TALBEHAT UNDER AGE(I) TALBEHAT
2021_MES_493613_1
AGE(I)/TBT/TOK-59/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
Exempted
14 Jan 2022
9 Dec 2021
10 Jan 2022
16 Dec 2021
8 Jan 2022
23 Dec 2021
60 days
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm deep in soft/loose soil complete all as specified and directed.
Excavation in tranches in soft/loose soil n exc 1.5 m wide and n exc 1.5 m depth and getting out for foundation complete all as specified and directed.
Excavating over area n exc 1.5 m deep and getting out in any type of soil complete all as specified & directed.
Excavating over area exc 1.5 m but n.exc 3 m deep and getting out in any type of soil complete all as specified & directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone as in foundation /sub base of floor, filling and mass concrete complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) type B-1,using 12.5 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses coping/channel benching of manhole, laid to shape and slope etc complete, all as specified and directed.
M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for Brickwork with old size sub class B bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Removing excavated material and thrown exc 250mtr but n.exc 500 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point.
Returning filling in including spreading levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
M&L for form work fair finished to edges of concrete flats, treads floor and roofs n exc 20 cm wide and sides of RCC/PCC bends in walls (horizontal or slopping) and similar works exc 10 cm but n exc 20 cm wide complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished etc complete all as specified
S&F TMT bars 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire [annealed] not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Same as per Item 15.00 above but 6 mm to 8 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F MS round bar of 10mm dia and over as in rungs/handle for manhole cover/Septic tank cover conforming to Fe-410-W (Gde. E-250) complete all as specified and as directed
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate Foundations, beams, plinth beams, base of column, lintel band, roof beam etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in chajjas all as specified and directed by Engineer-in-Charge.
M & L for RCC 1:2:4 (Nominal Mix), type B1, using 20mm graded crushed stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. complete all as specified and directed.
M&L for providing precast cement concrete type B-1 1:2:4 20 mm graded aggregate as in cover slabs for manholes/septic tank/drains & set in CM 1:4 complete all as specified and as directed.
M&L for brick bats for side of soakage well or inner portion complete all as specified and directed.
M&L for 150mm dia SGSW drain pipes laid in trenches and jointed complete all as specified.
M&L for concrete bed to drain pipes including packing under and hunching against the sides of pipe they are laid with PCC 1:4:8 type D-2 for pipe of 150mm dia in bore complete all as specified and directed.
M & L 15mm thick plaster in CM 1:6 on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for rendering in cement mortar (1:3) 10mm thick as in ceiling surfaces finished even and smooth complete all as specified and directed by Engineer-in-Charge.
M&L for Neeru finish to plastering complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls & applying three coat of white wash complete all as specified and directed
M&L preparation new plastered surfaces of wall and providing two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed.
S&F steel window/Ventilator with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete but without glazing bars, complete all as specified and directed.
S&F steel window/Ventilator with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete but with glazing bars, complete all as specified and directed.
M&L for MS framed work such as 10mm square guard bars conforming to Fe 290-0 or Fe 330-0 welded to ventilator/window complete all as specified and directed
M&L for Hard core of gauge n exc 63mm broken stone boulders ,deposited ,spread levelled and well rammed in layers n exc 15cm thick all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC 1:4:8 type D-2 as in sub base of floor using 40mm graded crushed stone aggregate complete all as specified and directed.
M & L for Non-skid coloured Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), complete all as specified and directed.
M&L for coloured Glazed ceramic tiles 450 x 300 x 7mm thick tiles on walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile over and including cement mortar 1:4, 10mm thick complete all as spd & directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20 mm thick crushed stone aggregate) as in sub base or similar work complete all as specified and directed.
M&L PCC (1:3:6) type C-2 using 20mm graded stone aggregate 75 mm thick as in plinth protection & similar work finished fair even laid in alternate bays n.exc 2m in length all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M S square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 146 of SSR Part - II 2004 complete all as specified and directed.
S&F butt hinges 100mm extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed.
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed.
S&F 100 mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F bevelled edge looking mirror 5.5mm thick of size 60cmx 45cm mounted on commercial plywood 6 mm thick including PVC beading all round and fixed to wooden plugs with chromium plated screws complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat red oxide complete all as specified and directed by Engineer-in-Charge.
S&F rolled mild steel section work as in main and cross beam, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates confirming to Fe 410W(Gde E-250 quality A)complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick, Trapezoidal roofing profile with 190 mm Pitch & 29 mm depth of profile of any colour having tensile strength of 550 Mpa fixed with self tapping screws as specified & directed.
S&F stainless steel wire cloth ,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as in wooded/iron frame complete all as specified and directed by Engineer-in-Charge.
S&F 3.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as spd & directed.
S&F Vitreous China wash basin, white, flat back, size 550x400mm including brackets, Waste coupling 32mm of PTMT (half or full threaded) (Minimum weight 32mm 45gms),waste pipe complete all as specified and directed
S & F Vitreous China, Squatting pan Orissa pattern size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe ) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe , including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and directed.
S&F PVC valveless syphonic action type low level flushing cistern, 10 Ltrs capacity White, with inlet ball valve, float, handle with 32mm PVC flush pipe, fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed.
S& F rotational moulded synthetic (HDPE) water storage tank 500litre capacity (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I complete all as spd & directed.
S&F ball valves PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20mm bore compete (Minimum weight 210 gm.) complete all as spd & directed.
S&F in repairs gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20 mm dia, ISI marked complete all as spd & directed.
S&F pillar taps fancy type cast copper alloy capstan headed, chromium plated, screwed down, high pressure with long screwed shank and fly nut, screwed for 15mm bore iron pipe complete all as specified and directed.
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as sped & directed.
S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as sped & directed.
S&F in repairs Fancy type chromium plated stop valve 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as spd & directed
S&F Chromium plated bib taps, with capstan heads, screwed down for iron pipe or for brass ferrule & fixed for 15 mm bore pipe complete all as specified & directed.
S&F Chromium plated concealed stop cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as spd & directed.
S&F brass chromium plated shower rose of 125mm size with swivel joints, incl . Fixing to steel pipe or union of 15mm bore complete all as specified and directed.
S&F grating square 125mm size of PTMT with centre hole movable or side hole for fix to waste pipe (min weight - 100 gms) complete all as specified and directed.
S&F 15mm bore , 450mm long PVC connection with PTMT nuts complete all as specified and directed.
S & F water tubing 15 mm bore, medium weight, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed.
S & F water tubing 20 mm bore, medium weight, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed.
S&F PVC floor/nahani trap with grating 75mm dia fixed with lead joint including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, laid in trenches or in floors of bore 110mm complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, laid in trenches or in floors of bore 75mm complete all as specified and directed.
S&F PVC (SWR) 110 mm bore bends (any radius) fixed with cement joint complete all as specified and directed.
S&F PVC (SWR) 75 mm bore bends (any radius) fixed with cement joint complete all as specified and directed.
S&F PVC (SWR) 110 mm bore vent cowl complete all as specified and directed.
S&F stack clamp out of 50mm by 3mm flat iron and 16 mm dia round iron stays fixed to pipe of bore 110mm complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth and removing surplus soil to a distance n.exc 50 m in soft/loose soil complete all as specified and directed.
M&L for PCC 1:3:6 , type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
S&F MS plate or angle, channel, square cut or notched with riveted, bolted, or welded attachment confirming to Fe 410-W Gde E- 250) quality A complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in floors complete.
M&L for machine cut Kota stone slab of size 550mm x 550mm flooring 20-25mm thick over and incl 15mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting , grinding rubbing and polishing complete all as specified.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5/6 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
S&F Switch Piano Flush button single pole one way 5/6 Amp.
S&F ceiling rose surface Bakelite 65mmx50mm three terminal.
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Lamp holder/Batten holder PVC/Polycarbonate insulated body with back plate for batten fitting including 9 watt LED bulb.
S&F sheet metal enclosure for MCB DB single pole and neutral 4 way 240 volts double door (Metallic) type including with SP & SPN MCBs.
S&F MCB SP 5 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 20 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Supply and fixing hook type GI tubes service bracket light grade 40 mm dia, 3 mtr length for support of cables, on pole/wall including clamp and nut bolts.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed 10 sq.mm 2 core nominal cross section in service connections cable as directed by Engr-in Charge.
Supply and fixing LED 4' batten light 18/20 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of 3 phase four wire LT CT operated unidirectional meter, CTR/5A, PTR/110V, class accuracy- 0.5 with 04 Nos CT Ratio 300/5A and necessary wiring and fittings alongwith fixing into suitable outdoor type IP 54-PVC meter box with handle and locking arrangement including all accessories and fixing as per site requirement complete all as specified and directed by Engr- in-Charge
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/S Kharya Associates
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .