Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹25.6 L+₹1.9 L (7.90%)Rejected-Finance 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹28.0 L+₹4.2 L (17.8%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹30.7 L+₹7.0 L (29.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹35.4 L+₹11.6 L (48.9%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Sept 2024, 6:00 pmClosed
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN 226002 C/O 56 APO
REPAIR/ RENEWAL TO INTERNAL ELECTRIFICATION AT VARIOUS OTM ACCN OF ZONE A B C AREA OF AGE E/M (WEST) UNDER GE (WEST) LUCKNOW
2024_MES_666592_1
GE/W/LKO/64 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
LUCKNOW
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹0
₹80,000
Yes
11 Oct 2024
18 Jul 2024
26 Sept 2024
18 Jul 2024
19 Sept 2024
1 Aug 2024
18 Jul 2024 - 25 Jul 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc for taking credit and making good disturbed surfaces of walls, floors,etc. complete all as specified and as directed.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC(FRLS)insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per Item No 2 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 2 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
All as per Item No 2 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
All as per Item No 2 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into and including suitable size surface conduit/casing caping, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per Item No 7 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 7 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per Item No 7 above but for One bell/ buzzer point controlled by one bell push
All as per Item No 7 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into existing conduit, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per Item No 12 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per Item No 12 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per Item No 6 above but for One bell/ buzzer point controlled by one bell push
All as per Item No 12 above but for One light point controlled by two 2 way switch
All as per Item No 12 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm.
M&L for point wiring with single core FRLS PVC insulated 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) drawn in and including non metallic rigid PVC concealed conduit, medium grade ISI marked not less than 20 mm dia, concealed in wall, ceiling with saddles, screw & Plugs with all fittings including tee, junction boxes and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm and terminated in and including sunken box for modular switches/sockets, regulators etc complete all as specified and directed. (a) One light/fan point controlled by one switch
One socket outlet point 5 Amp on an independent board complete all as specified and directed.
Same as item No 18 but on the same board complete all as specified and directed.
All as per Item No 18 above but for One bell/ buzzer point controlled by one bell push complete all as specified and directed.
All as item No 18 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as specified and directed.
S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed.
S&F switch piano flush button single pole two way 5 Amp 240 volt complete all as specified and directed.
S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and16 Amp, 230 volts complete all as specified and directed.
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6Amp, 230 volts complete all as specified and directed.
S&F fan regulator electronic,step up socket type,230 volt,125 W and conection complete all as specified and directed.
S&F modular switches 1 way 6A,1 module complete all as specified and as directed.
S&F modular switches 1 way 16A,1 module complete all as specified and as directed.
S&F modular 6 A sockets-5 pin 2 module complete all as specified and as directed.
S&F modular 6A/16A sockets-3/5 pin combine 2 module complete all as specified and as directed.
S&F Modular white cover plate with frame 8 module complete all as specified and as directed.
S&F Modular white cover plate with frame 6 module complete all as specified and as directed.
S&F Modular white cover plate with frame 4 module complete all as specified and as directed.
S&F Modular white cover plate with frame 3 module complete all as specified and as directed.
S&F Modular white cover plate with frame 2 module complete all as specified and as directed.
S&F modular bell push single pole one way 6/10 Amp, 240 volt,1 module, fuesh type complete all as specified and directed.
Supply and fix modular type blanking plates, one moudle complete all as specified and directed.
Supply & fix modular fan regulator 120/100 W, 2 Module for ceiling fan fixed, in board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and directed.
S&F ceiling rose surface bakelite three terminal complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F bell push single pole one way 5 Amp, 240 volt fuesh type as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F call bell AC single pole 240 volt ding dong Type. complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F angle type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing wall/surface mounting luminaires (Mirror Light) integrated LED Batten( 2 feet) 10/12 W, 6500 K, 230V , minimum 120 lumens/watt,with extruded aluminium housing & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repair LED Building security light 40/45 Watt with high power LED source (>100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories ,complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and Fixing wall/surface mounting luminaires integrated LED Batten 20/22 W, 6500/4000 K,120 lumens/watt , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver, 25k burning hours ,2.5 KV surge protection complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S& F in repair Decorative wall light fixture made up of Metal base, synthetic white in colour and square/round metal base with bend pipe and glass globe with nickel finish, ( B-22/E27 base), with 01 No. 7/9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connecting arrangements complete all as specified and as directed. Note: Rates incl 01X 7/9 W LED Bulb with each fitting Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S& F in repair Decorative wall bed light fixture made up of Metal base, synthetic white in colour and round metal base with bend pipe integrated LED type, 230 V, 3000K, complete incl all required electrical connecting arrangements all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repair LED Building security light 20/25 Watt with high power LED source (>100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S & F in replacement of GI pipe light grade, 32 mm bore, 1.20 mtr long bend in required shape, MS clamp 40x3mm thick duly painted with two coats of synthetic enemal paint fixed on wall including bolts and nuts complete all as specified and directed.
S&F 30 W flood light LED fitting Warm/day cool as required, IP 65 protection, minimum 100 lumens/watt with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and as directed . Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repairs of surface type round/Square LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repairs of recesssed type square LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing LED lamp 9/10/12 watt, complete all as specified and as directed.
S&F in repair super bright LED (2X2), 36 W, 6500 K recess/surface mounting minimum 100Lumens/watt IP20 ,IK02 PF>.9 and 4kv inbuilt surg protection with high efficent LED source complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing in repair FTL fittings with decorative LED batten made up of aluminium casting 18/20 W of size complete standard fittings and fixtures including fixing on walls/roofs/ through MS downrod suspended type with fitting arrangement including neccessary elect connection from ceiling rose to luminaries with suitable size PVC cord complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing in repair Material glass led tube ,voltage range 220-240v-50hz ,cct 6500k,lumen ,wattage 20/22W surge 2.5kv ,CRI 80 POWER FACTOR >_0.9 ,BURING HOURS 25K HOURS 120 L/W ,6000 K with high efficency, with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S & F in repairs integrated LED type Post top lantern with high power 25/30 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl neceesary electrical connection complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F LED 7/9 Watt LED emergency lamp 6500K automatically turn on AC to DC while power cut, inverter battery AC/DC (6 Hrs Backup), rechargeable, cool white as required complete all as specified and as directed.
S & F in repairs integrated LED type Bollard , 12 W LED as light source, IP 65, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution incl LED driver with base plate and pcc and earth work for grouting the light complete and incl neceesary electrical connection complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in replacement sub main wiring with two single core PVC FR insulated multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 2.5 sqmm nominal cross sectional area PVC FR insulated multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC FR insulated multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC FR insulated multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC FR insulated multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 2.5 sqmm nominal cross sectional area PVC FR insulated multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC existingconduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
Supply and fixing in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing in replacement for 2.5 sqmm single core copper,multi standard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing in replacement for 4 sqmm single core copper, multi standard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S & F three core PVC insulated FRLSH sheathed cable with 1.5 sqmm stranded copper conductor complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 32/40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, triple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
Supply and fixing modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar etc IK09, True IP 43 (with PU Gasket) with test certificate incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and as directed. Note: MCCB & MCB to be measured and paid seprately
S&F MCCB 63-125 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and as directed.
S&F 50 W flood light LED fitting Warm/day cool as required, IP 65 protection, minimum 100 lumens/watt with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and as directed . Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing PVC casing and caping,15/ 20mm wide complete all as specified and as directed
S & F in replacement of switch piano flush button single pole one way 5/6 Amp 240 volt complete all as specified and as directed.
S & F in replacement of switch piano flush button single pole one way 15/16 Amp 240 volt complete all as specified and as directed.
S&F in replacement of socket outlet flush type multipurpose 2 in 1, 3 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and as directed.
S&F in replacement of unservicable socket outlet flush type multipurpose 2 in 1, 6pin 5 .Amp, 230 volts complete all as specified and as directed.
S&F in replacement of switch socket outlet combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and as directed.
S&F in replacement bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed.
S&F in replacement call bell AC single pole 240 volt ding dong Type. complete all as specified and as directed.
S&F in replacement angle/batten type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.
S&F in replacement PVC gang box fitted with and including piano type switch 5 A and socket 5 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.
S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.
S & F rectangular laminated hylum sheet top cover for switch sockets of size' (125mmx125mmx3mm) complete all as specified and as directed.
Same as item 92 here in before but (200mmx125mmx3mm) complete all as specified and as directed.
Same as item 92 here in before but (225mmx275mmx3mm) complete all as specified and as directed.
S&F in repairs of recessed type round type LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repairs Flexiion 5 Mtr LED strip 22 W, 3000K/6000K as required on site with driver with wide viewing angle for good light distribution, easy to install complete all as specified and as directed.
S&F in repairs outdoor type Flexiion 50Mtr LED strip IP65 Water-Proof Rope and Strip Light, 3000K/6000K as required on site with driver with wide viewing angle for good light distribution, easy to install complete all as specified and directed Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fixing in replacement for flexible wire twin core copper,multistandard PVC insulatedunsheathed, cable 1100 volts grade complete all as specified and directed Makes shall be provided group-I cat as per latest approved make given by HQ CECC NOTE: FOR ITEM NO. (1)- 45 to 98 day to day complaint will have to be rectified by the contractor with in two days (upto 40 nos of complaint per day). (2) Penalty will be made Rs 100 per day for delay beyond two days (3) Complaint will be collected by the rep of Contractor/supervisor from MGSF complaint cell
M & L of Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and directed .
suniltraders (BID ID -3085579)
M/S Reliance Construction (BID ID -3093923)
M/s PS Associates (BID ID -3093141)
M/S KAUSHIK CONSTRUCTION (BID ID -3094257)
m/s raghubar dayal (BID ID -3093322)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .