| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC | ₹1.4 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹1.8 Cr+₹43.7 L (31.6%)Rejected-AOC FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹1.8 Cr+₹43.7 L (31.6%) | 2 | Rejected-AOC Being not L1 |
| 3 | 3₹1.9 Cr+₹50.4 L (36.4%)Rejected-AOC | ₹1.9 Cr+₹50.4 L (36.4%) | 3 | Rejected-AOC Being not L1 |
| 4 | 4₹2.3 Cr+₹92.5 L (66.8%)Rejected-AOC | ₹2.3 Cr+₹92.5 L (66.8%) | 4 | Rejected-AOC Being not L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
9 Nov 2021, 6:00 pmClosed
CE RandD Secunderabad
CE RandD Secunderabad Opp Jubilee BusStation, Picket
PROVISION OF NEW BOUNDARY WALL IN LIEU OF BARBED WIRE FENCING AT DEVATALAGUTTA OF DMRL, HYDERABAD
2021_MES_479538_1
PROVISION OF NEW BOUNDARY WALL IN LIEU OF BARBED W
Open Tender
Civil Works
Lump-sum
270 days
Hyderabad
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (I) R and D Kanchanbagh, Hyderabad
₹2.1 L
Yes
13 Dec 2021
4 Oct 2021
16 Nov 2021
4 Oct 2021
9 Nov 2021
25 Oct 2021
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Watch Tower cum Rest Room building in double storeyed RCC framed structure complete all as shown on drawings and as specified.
Schedule 'A' Part - II (EXCAVATION, EARTHWORK AND SITE CLEARANCE) This Schedule (contains under mentioned Sl. item Nos. 2.01 to 2.04) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. The unit rates quoted against item Nos. 2.01 to 2.04 is deemed to be included execution of work either manually or by mechanical means.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations, cesspits, manholes and sewage lines, etc. or for laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard / dense soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard rock, complete all as specified and directed.
Returning, filling in, in any type of soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing surplus excavated material (soils) to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Lump sum price worked out by the Contractor for “COMPOUND WALL AND FENCING” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `1,66,99,117.33 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part - IV representing _____ % __________ percent Above / Below the lump sum price of `9,515.14 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - V representing ______ % _______________ percent Above / Below the lump sum price of `2,04,000.10 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `65,516.76 inserted by the MES in Schedule ‘A’ Part - VI
Schedule 'A' Part - VII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 7.01 to 7.22
COMPOUND WALL AND FENCING Razor edge concertina coil 610mm dia, consisting of sprials with sharp edged tap of 0.5mm thick, crimped to 2.6mm dia high tensile steel wire duly galvanised as per IS 4454 with scrapper barb having 51 sprials with 125 clips (when stretched to a length of 6 metre), weight of each coil shall be 8 to 9 Kg approximately) and fixed to MS frame work 'Y' shaped and placed at1.5m apart and tied with GI stapples/clips to retain horizontal including provision of necessary bolts, nuts etc., complete all as specified and directed.
Drilling holes in hard rock by using drill / mechanical tools, area not exc 0.10 Cum, tools getting out to a depth minimum 300 mm and grouting with Removing surplus excavated material (soils) to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed. Notes for Sl item Nos. 7.01 & 7.02: - (i) Site / Location of Compound Wall to be constructed on Hillock and 'No access/Approach Road' is available to some location where Compound Wall to be constructed. T & P / Materials may be required to be lifted/shifted through Head loads / on any other arrangements. (ii) The tenderers are advised to visit the site to ascertain the working conditions at site. The rates quoted shall be deemed to include considering all these site conditions and nature of works involved in the subject tender. No extra charges what so ever shall be allowed.
INTERNAL ELECTRIFICATION Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point / fan point controlled by one 6 Amps one way modular switch, complete all as specified and directed. Note: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.
All as per Sl. Item No. 7.03 here-in-before, but for one 3 pin, 5 Amps modular switch socket controlled by one, one way switch on independent board.
All as per Sl. Item No. 7.03 here-in-before, but for one 3 pin, 5 Amps modular switch socket controlled by one, one way switch on same board.
Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one switch socket outlet point 15Amp on independent board, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.
All as per Sl. Item No. 7.03 here-in-before, but for one light point controlled by two, 6 Amps two way modular switch.
LED tube light fitting, batten type, 20Watt, 230Volts energy efficient, with driver, mounting acessories, connector block etc., complete with all accessories internally pre-wired and including connecting up with three core sheathed copper flexible cable of 1.5 sq.mm up to light fitting complete, all as specified and directed. Make: - Model No. LUMILINEPLUSBS22WLED865SPCSS of Havells or techno-commercially equivalent model in Philips / Wipro / Bajaj / CG
Street light fitting with IP 65 type protection, 35 W, 230 Volts, AC, 50 Hz and made of pressure die cast aluminium housing with high power LED as ligting sources and embedded cover with driver, fixng on building including bracket made out of 40 mm dia light grade not less than 1.50 m long bent to shape fixed with suitable iron clamps and provision of 3 core PVC insulated, PVC sheathed copper conductor multistranded wire up to fitting complete, all as specified and directed. Make:- Model No. ENDURACITYLITEPLATPLUSSL35WLED 757SASYBOPC of Havells or techno-commercially equivalent model in Philips / Wipro / Bajaj / CG
Sub main wiring complete with two runs of of single core, 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (a) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (b) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15 mm bore dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metre shall be measured and paid under respective item of this Schedule.
MCB DB TPN 4 way metallic double door IP 54 protection, 415 V AC 50Hz with for MCBs as incomer and as out going with tinned copper bus bar of rated 250Amp neutral link earth link, complete all as specified and directed.
MCB TPN, 40 Amp, 415 Volts, 50 Hz, 'C' curve, 10 KA breaking capacity, complete all as specified and directed.
MCB SPN, 40 Amp, 230 Volts, 50 Hz, 'C' curve, 10 KA breaking capacity, complete all as specified and directed.
MCB SP, 5 to 32 Amp, 230 Volts, 50 Hz, 'C' curve, 10 KA breaking capacity, complete all as specified and directed.
Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5mFd, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, complete all as specified and directed.
EXTERNAL ELECTRIFICATION Cutting the road/hardstanding to a size not exceeding 30 cm in width and not exceeding 75 cm in depth for laying of LT UG cables / GI pipes including making good so as to match with the existing finish with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) for 100mm thick on top including fair finish, complete all as specified and directed.
EXTERNAL WATER SUPPLY Cutting the road/hardstanding to a size not exceeding 30 cm in width and not exceeding 75 cm in depth for laying GI pipe including making good so as to match with the existing finish with PCC (1:4:8) type D2 (using 40mm graded stone aggregate) for 100mm thick on top including fair finish, complete all as specified and directed.
Cutting existing steel tubing for alterations or additions up to 50mm bore of pipe (Each cut measured), complete all as specified and directed.
Supply, install, test and commissioning of mono block pump set, 1.5HP, three phase, 415 V, with discharge capacity of 0.64 LPS, speed 3000RPM, head 40m including necessary PCC (1:2:4) Type B1 work to fix the pump set, complete all as specified and directed. Make: - Model No. GMC 1.540 of Kirloskar or techno-commercially equivalent model in Crompton Greaves / Jyothi / Grundfos
Non Return Valve, with iron wheel head, screwed both ends for iron pipe and fixed, 25mm dia, complete all as specified and directed.
DOL starter of 3 phase, 415 Volts, 50 Hz suitable for 2HP capacity monoblock pump including all internal connections with suitable size of copper wire, testing and commissioning including angle iron frame pedestal type enclosure made out of 2mm thick MS sheet with 50x50x6mm thick angle-02 Nos legs duly embedded in ground with PCC (1:3:6) Type C1 foundation and other end fixed by nut& bolts or welded to panel, complete all as specified and directed.
M/s. P S REDDY
c devender reddy and co
INDGUARD ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .