Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
15 Mar 2021, 11:00 amClosed
EXECUTIVE ENGINEER (ELECTRICAL)/SOUTH ZONE
SOUTH DELHI MUNICIPAL CORPORATION Office of the Executive Engineer (Electrical)-IV MC Primary School, Police Colony Hauz Khas, New Delhi-110016
Repair of Electrical installations at SDMC Crematorium, Green Park Extension in ward no. 61-S under South Zone
2021_SDMC_72541_1
NIT NO.20 ITEM NO.04
Open Tender
Electrical Works
Item Rate
10 days
SDMC Crematorium, Green Park Extension
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Commissioner SDMC
Exempted
18 Mar 2021
9 Mar 2021
16 Mar 2021
9 Mar 2021
15 Mar 2021
9 Mar 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group-C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.3x 2.5 sq. mm
3x4 sqmm
3x6 sqmm
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supply of XLPE insulated PVC sheathed Al. Conductor Un Armoured Cable 1.1 KV grade confirming to IS -7098 of following size:- 2 x 6 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 kA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
12 way, Double door
16 way, Double door
6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.B) 40 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.B) 63 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
Supply of 1200 mm sweep 50 Watt, Energy saver ISI marked BEE 5 star rating AC Ceiling fan suitable for 230V , 5 hertz AC supply witout regulator blades, downrod etc. complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required
Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required
Supply of 18" (450mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
SITC of 30 W LED Flood light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specifications as reqd. (b) Total system wattage = 30 watt +/- 5% (d) Luminaire efficacy = 100 Lm/w (e) Power factor = 0.95 (f) Protection class - IP -66
P/F hot press sheet moulded compound SMC (Fire retardant) (temperature resistance upto 200 degree Celcius) IP 55 weather proof pole box of inner dimension 200mm x 160 x 98mm (NS) complete with suitable arrangement for fixing of 02 nos of 6 amp to 32 amp single pole MCB and 63 Amp double pole isolator (MCB/Isolator excluded) with neutral link duly sorting on DIN channel with 02 nos MS clamp with SS back plate of suitable size with danger monogram property printed on the cover etc as required.
S/I/T/C of LED tube type luminaire 20 watt rating complete with Extruded Aliinium batten prewired with high efficient LEDs with the following ( a) Total System wattage 20 watt +/- 5% (b) Liminous efficacy lumens /watts =95 ( c ) Power Factor =.95
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
M/s New Gupta Electric Works
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .