Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.7 L+₹2.4 L (9.53%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹30.2 L+₹4.9 L (19.4%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹30.2 L+₹4.9 L (19.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹30.3 L+₹5.0 L (19.6%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹27.6 L
EMD Value
₹55,180
Closing Date
13 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
PROVISION OF UPS FOR ESSENTIAL EQUPEMENTS HELD IN ICU, OT AND EMERGENCY IN MH UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_654400_1
GE/ASR-48/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹55,180
21 Sept 2024
16 May 2024
14 Jun 2024
16 May 2024
13 Jun 2024
30 May 2024
Amount
Supply installation test and commissioing of online UPS for 30 min back up single phase AC input 110 to 300 V and out put 230 ± 1%, microprocessor controlled generator compatible , autoby pass and emergency power off, pure sign wave with following specifications of capacity 3 KVA, Make Luminous Model LD 3000 or equivalent in Microteck / schneider ; Complete all as specified and directed by Engineer-in-charge. Voltage regulation - 1% ( battery Mode) Frequency at Battery mode - 50+/-0.25Hz Harmonic distortion less than or equal to 3% THD ( linear load) Harmonic distortion less than or equal to 6% THD ( non linear load) Efficiency not less than 90% on AC mode and not less tha 88% on Battery mode Battery type -26 AH SMF Battery make - Amron Quanta/Exide-.12 nos Battery stand with battery interlinks of copper LCD Indicators - Load level,battery level, AC Mode, battery mode,By pass mode, fault indicator Alarm- battery mode/Low battery/ Overload/Fault Humidity -20-95% Noise level-50dBA @ 1 mtr Communication -Smart USB port/RS-232,SNMP card slot
Supply installation test and commissioing of online UPS for 30 min back up single phase AC input 110 to 300 V and out put 230 ± 1%, microprocessor controlled generator compatible , autoby pass and emergency power off, pure sign wave with following specifications of capacity 6 KVA Make Luminous Model LD 6000 or equivalent in Microteck / schneider ; Complete all as specified and directed by Engineer-in-charge. Voltage regulation - 1% ( battery Mode) Frequency at Battery mode - 50+/-0.25Hz Harmonic distortion less than or equal to 3% THD ( linear load) Harmonic distortion less than or equal to 6% THD ( non linear load) Efficiency not less than 90% on AC mode and not less tha 88% on Battery mode Battery type -26 AH SMF battery make - Amron Quanta/Exide- 32 Nos Battery stand made of iron with battery interlinks LCD Indicators - Load level,battery level, AC Mode, battery mode,By pass mode, fault indicator Alarm- battery mode/Low battery/ Overload/Fault Humidity -20-95% Noise level-50dBA @ 1 mtr Communication -Smart USB port/RS-232,SNMP card slot
Supply installation test and commissioing of online UPS for 30 min back up three phase AC input and three phase out put 3x400V AC (3Ph+N), microprocessor controlled generator compatible , autoby pass and emergency power off, pure sign wave with following specifications of capacity 10 KVA Make Luminous Model LD 10K3P3P or equivalent in Microteck / schneider Voltage regulation - 1% ( battery Mode) Frequency at Battery mode - 50+/-0.25Hz Harmonic distortion less than or equal to 2% THD ( linear load) Harmonic distortion less than or equal to 5% THD ( non linear load) Efficiency not less than 90% on AC mode and not less tha 88% on Battery mode Battery type - 42 AH SMF battery make- Amron Quanta / Exide-40 nos Iron rack for battery with battery interlinks of copper with lugs LCD Indicators - Load level,battery level, AC Mode, battery mode,By pass mode, fault indicator Alarm- battery mode/Low battery/ Overload/Fault Humidity -0-95% Noise level-60dBA @ 1 mtr Communication -Smart USB port/RS-232,SNMP card slot Transfer time from AC mode to battery mode -zero Transfer time from Invertor to bypass mode -zero
Supply installation test and commissioing of online UPS for 30 min back up three phase AC input and three phase out put 3x400V AC (3Ph+N), microprocessor controlled generator compatible , autoby pass and emergency power off, pure sign wave with following specifications of capacity 20 KVA Make Luminous Model LD 20000-Luminous Pro 3/3-20K or equivalent in Microteck / schneider ; Complete all as specified and directed by Engineer-in-charge. Voltage regulation - 1% ( battery Mode) Frequency at Battery mode - 50+/-0.25Hz Harmonic distortion less than or equal to 2% THD ( linear load) Harmonic distortion less than or equal to 2% THD ( linear load) Harmonic distortion less than or equal to 5% THD ( non linear load) Efficiency not less than 90% on AC mode and not less tha 88% on Battery mode Battery type - 65 AH SMF battery make- Amron Quanta / Exide- 40 nos Iron rack for battery with battery interlinks of copper with lugs LCD Indicators - Load level,battery level, AC Mode, battery mode,By pass mode, fault indicator Alarm- battery mode/Low battery/ Overload/Fault Noise level-65dBA @ 1 mtr Communication -Smart USB port/RS-232,SNMP card slot Transfer time from AC mode to battery mode -zero Transfer time from Invertor to bypass mode -zero
Supply and Fixing MCB DB DD SPN 8 Way with earth and neutral bus and Bus bar of size 200 Amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB DB DD TPN 4 Way with earth and neutral bus and Bus bar of size 200 Amps ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Sub main wiring in and incl concealed conduit PVC med grade ISI marked of size not less than 20 mm complete with chase cutting and redressing of surfaces comeplete all as spevcified and directed for Single phase with three 4 Sqmm copper wire FRLS,1100 v grade ( phase neutral and earth) ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Sub main wiring in and incl concealed conduit PVC med grade ISI marked of size not less than 25 mm complete with chase cutting and redressing of surfaces complete all as spevcified and directed for three phase Supply with six 6 Sqmm copper wires FRLS,1100 v grade ( 3phase neutral and 2 earth) ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB 4 Pole 415V 10 KA, 0-32 Amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB Single Pole 240V 10 KA, 0-32 Amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB Double Pole 240V 10 KA, 0-32 Amps ; Complete all as specified and directed by Engineer-in-charge.
UNITED ENGINEERING CORPORATION
kailu construction co
Bharatbuilder
WAVESHAPES INDIA
satpal and brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .