| 1 | Endress Hasuer (I) Pvt. Ltd. L-1₹72.4 LAccepted-AOC | L-1 | Accepted-AOC Quoted rates are reasonable | |
| 2 | L-2₹10.0 L−₹62.4 L (86.2%)Rejected-Finance 108 RZC C SECTOR 01 MAHAVIR ENCLAVE SOUTH WEST DELHI 110045 | DELHI | SOUTH WEST DELHI | DELHI | 110045 | L-2 | Rejected-Finance Quoted rates are not reasonable | |
| 3 | Rejected-Technical 22 BEHIND MODERN PETROL PUMP BEHIND MODERN PETROL PUMP JHALAWAR ROAD KOTA KOTA RAJASTHAN 324007 | KOTA | RAJASTHAN | 324007 | - | Rejected-Technical bidder does not fulfil QR,technically ,commercially |
Tender Value
₹50.2 L
EMD Value
₹1.0 L
Closing Date
2 Aug 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer(MM)
Admin Building KaTPP Near Undal Village Dist.-Jhalawar Rajasthan PIN-326023
SUPPLY OF PRESSURE TRANSMITTER (PT) AND DIFFERENTIAL PRESSURE TRANSMITTER (DPT) AT KATPP, JHALAWAR
2023_RRVUN_337690_1
TN-1001(MM)
Open Tender
Electronics Equipment
Item Wise
90 days
KaTPP, Near Village Undal
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Sr Account Officer, KaTPP Jhalawar
₹1.0 L
2 Aug 2024
25 May 2023
2 Aug 2023
25 May 2023
2 Aug 2023
25 May 2023
DPT SH Ist & II nd stage Flow tx,RH DSH Flow,BLR Cont.blowdown Flow Unit: Kpa measuring range-: -500 to 500 User Range/calibration Range:0 to 250
DPT Drum Level Tx. Unit: mmH2O measuring range-: -800 to 800 User Range/calibration Range: -600 to500 mmH2O
DPT PA Flow, APH PA inlet & outlet DP, secondary air flow, APH SA Inlet & Outlet DP Unit: Kpa measuring range-: -2.0 to 2.0 User Range/calibration Range:0.1 to1.5
DPT Feed Control Stn In &Out DP Unit: Mpa measuring range-:- -0.12 to10.0 User Range/calibration Range:0 to 10.0
DPT SH Spray water flow Unit: Kpa, measuring range-: -500 to 500 User Range/calibration Range:0 to 500
DPT RH Spray Water Flow,Main Feedwater Flow Unit: Kpa measuring range-:-160 to 160 User Range/calibration Range:0 to 60
DPT Cont.blowdown tanklevel Tx Unit: mmH2O measuring range-:-0.0 to 1500 mmH2O User Range/calibration Range:0.0 to1500
DPT LDO Tank level TX (Capillary type) Unit: mmH2O measuring range-:0 to 8500, User Range/calibration Range: 0 to 8500
DPT HFO tank level Tx ( Capillary type ) Unit: mmH2O measuring range-: 0 to 13000 User Range/calibration Range: 0 to 13000
PT Furnace Press Tx., APH Inlet and Outlet Gas Press, ESP Intel Gas Press, ID Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, measuring range-:-8.0 to 8.0, User Range/calibration Range: -8.0 to1.0
PT Main Feedwater Press, Drum Press Tx.,SH Out Press, Main Steam Press, SH Spray water press.,Main feedwater MOV front press., Cont. blowdown tank Press. Tx Unit: Mpa measuring range: -0.1 to 40.0 User Range/calibration Range: 0 to 30.0
PT Secondary Air Pressure Tx., APH Inlet sec air press, FD Fan Out Press, Furnace sec. air Box Press, Furnace Pressure Unit: Kpa, measuring range-: -60 to 60 User Range/calibration Range: -7.0 to 7.0
PT APH out Hot PA Press, APH Inlet PA Press , mill separator outlet pressure ,mill Sealing air pressure, mill PA pressure scanner air outlet pressure Unit: Kpa measuring range-:-100 to 400, User Range/calibration Range:0 to 30.0
PT ID Fan Outlet Press Unit: Kpa, measuring range-:-2.0 to 2.0 User Range/calibration Range:0 to 2.0
PT CW/ACW Header Pressure ,Instrument Air Pressure, CW outlet pressure IAC/CAC air pressure Unit: Mpa, measuring range-:0 to 1.5 User Range/calibration Range:0 to1.5
PT RH Spray Water Press, IBD Flash tank inlet Press. Tx,Turb ,RH Spray WTR Press RH Inlet /Outlet Press Unit: Mpa measuring range-:-0.1 to 16.0 User Range/calibration Range:0 to 15.0
PT Turbine STM PRS After Gov Stage1 Unit: Mpa measuring range-:0 to 15 User Range/calibration Range:0 to 15
PT No1 HPH I/L STM PRS Unit: Mpa, measuring range-:0 to 10 User Range/calibration Range:0 to 10
PT HPBP Behind STM PRS 1, HP Turb Exhaust STM LEFT PRS , HP Turb Exhaust STM Right PRS, HP Turb Exhaust STM HDR Pipe PRS ,Reater I/L STM PRS,CRH to BEPT STM PRS, RH o/L STM Press , RH o/L STM Press , RH o/L STM Press , No2 HPH I/L STM PRS, CRH TO BFPT STM PRS, Cold RH STM To AUX STM PRS, No 2 HPH I/L STM Unit: Mpa, measuring range-:0 to 6 User Range/calibration Range: 0 to 6
PT Dearator Press 1,4 Sect. Extr. To Aux STM PRS,4 Sect. Extr. To Dea Mov FRT PRS,4# Extr. To MFPT Press,Aux STM To BFPT STM PRS.,MFPT A I/L STM PRS.,AUX STM To BFPT STM PRS,GEN STAT CW I/L WTR Flow,No5 LPH I/L STM PRS,Turb HP&IP Gas Gland STM PRS. 1,GEN Entering Hydrogen Pr. No5 LPH I/L STM PRS Unit: Mpa, measuring range-: 0 to 2 User Range/calibration Range:0 to 2
PT LPBP VLV(HP) Behind STM PRS 1 LPBP VLV ( LP) Behind STM PRS 1 Unit: Mpa, measuring range-:-0.2 to 2 User Range/calibration Range: -0.1 to 2
PT No7 LPH A&B I/L STM PRS No8 LPH A&B I/L STM PRS 1 Unit: Mpa measuring range-:-0.1 to 0.1 User Range/calibration Range: -0.1 to 0.1
PT CP INL Press Unit: Mpa measuring range-:-0.1 to 0.5 User Range/calibration Range: -0.1 to 0.5
PT Lub oil of Turb PRS Unit: Kpa measuring range-: 0 to 5500, User Range/calibration Range:0 to 5500
PT HP Cond Vacuum Pres 1, LP Cond Vacuum Press 1, HP COND VACUUM PRS 1,LP COND VACUUM PRS 1, BFPT B Exhust vac Press, BFPT A Exhust Vac Press Unit: Kpa, measuring range-:-100 to 100 User Range/calibration Range:-100 to100
DPT TDBFBP A I/L Filter DP, TDBFBP 'B' I/L Filter DP TDBFBD O/L Feed WTR flow 2,TDFPA I/L Filter DP TDFP 'A' I/L Filter DP, MBFBP I/L Filter DP, MBFP I/L Filter DP, RH Spray WTR Flow, SH Spray WTR FLOW 1, 4# Extr. To Aux STM Flow, 4# Extr. To MFPT Unit: Kpa measuring range-:-0 to 100 User Range/calibration Range:0 to 100
PT Trub Self-Scanling Gland HTR PRS Unit: Kpa measuring range-:-100 to 600 User Range/calibration Range: -100 to 600
DPT GEN STAT CW Flow, Seal oil DP,HP BPV IN Steam flow Unit: Kpa measuring range-:0 to 250 User Range/calibration Range:0 to 250
DPT TDBFBP 'A' o/L Feed WTR Flow 1,TDBFBP 'B' O/L Feed WTR Flow 1,TDBFBP B O/L Feed WTR Flow 3 MBFBP O/L Feed WTR Flow 1 Unit: Kpa measuring range-:0 to 40 User Range/calibration Range:0 to 40
PT LDO , HFO SUPPLY AND RETURN PRESS (WITH CAPILLARY) Unit: Mpa measuring range-:0 to 5 User Range/calibration Range:0.1 to 5
PT PRDS HDR PRESS Unit: Mpa measuring range-:-0 to 6.3 User Range/calibration Range:0 to 5
PT MILL LOADING OIL PRESSURE Unit: Mpa measuring range-:0 to 40 User Range/calibration Range:0 to 25
DPT MILL SEALING AIR DP SADC/CADC PRESS DP Unit: Kpa measuring range-:-60 to 60 User Range/calibration Range:0 to 5
DPT HFO FILTER DP (WITH CAPILLARY) Unit: Kpa measuring range-: -500 to 500 User Range/calibration Range: -100 to 100
DPT LO FILTER DP (WITH CAPILLARY) Unit: Kpa measuring range-:-160 to 160 User Range/calibration Range:0 to 100
DPT MILL SEPAROTOR INLET/OUTLET DP Unit: Kpa measuring range-:0 to 40 User Range/calibration Range:0 to 20
DPT SCANNER FAN DP Unit: Kpa measuring range-: 0 to 8 User Range/calibration Range:0 to 6.2
PT SCANNER FAN Press., Mill Separator outlet Pressure, mill seal air pressure, mill PA pressure Unit: Kpa measuring range-:-100 to 400 User Range/calibration Range:0 to 30
AAKANKSHA ENTERPRISES
AAKANKSHA ENTERPRISES
techsummary_599184.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_599184.pdf
PDF • 0.02 MB
D985.pdf
PDF • 2.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .