| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 CrAccepted-AOC 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | ₹9.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹10.0 Cr+₹69.7 L (7.49%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹10.0 Cr+₹69.7 L (7.49%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹10.6 Cr+₹1.3 Cr (13.6%)Rejected-Finance | ₹10.6 Cr+₹1.3 Cr (13.6%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹11.8 Cr+₹2.5 Cr (26.4%)Rejected-Finance | ₹11.8 Cr+₹2.5 Cr (26.4%) | L4 | Rejected-Finance Other than L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected being two class below |
Tender Value
₹9.6 Cr
EMD Value
₹8.0 L
Closing Date
26 Dec 2020, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
CONSTRUCTION OF INFRA AT UAV NODE AT SCHOOL OF ARTILERY AT NASIK
2020_MES_382526_2
84498E8
Open Tender
Civil Works
Lump-sum
545 days
Nasik
Class S and above Category a(i)
7 documents required · 7 mandatory
₹3,000
GE Nasik Road Camp
₹8.0 L
Yes
Chief Engineer Pune Zone Dakshin Kaman Marg Camp
20 Jan 2021
8 Dec 2020
28 Dec 2020
8 Dec 2020
26 Dec 2020
15 Dec 2020
8 Dec 2020 - 12 Dec 2020
12 Dec 2020
Amount
NOTE: Schedule ‘A’ Part I (SECTION 'A'), Part II to XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (SECTION 'A') (Building Works)
Total amount of Sch 'A' Part-I (Section 'B) Pre Engineered Building (PEB) works and Light guage steel framed ( LGSF) and RCC Framed Structure, (Design, Fabrication & Construction of foundation, flooring & superstructure , etc complete all as given below:- Note :- This schedule is not pre-priced by MES and the rate indicated as "Rs. 0.00" under column 6 signifies this fact only.
Design, Fabrication and Construction of Maintenance Hangar of Size 50m x 42m x 4m clear height + Eaves height, plinth height 0.15m (FFL matching with adjoining Dispersal), etc with Pre-Engineered Building structure (PEB), as per specification given in Particular Specifications, with sloping galvalume sheet roofing (0.5mm thick profiled pre-colour coated galvalume sheet roofing) including turboventilators at appropriate locations, RCC (M-30 design mix) foundation and pedestal, Galvalume sheet wall cladding, bird proofing, Telescopic motorised hangar sliding door shutter with track rail, also including necessary strenghtening for seismic zone -III, (Excluding Flooring of maintanance hall and storage area Portion) complete all as specified and directed and as shown on drawings.
Design, Fabrication and Construction of CPA Hangar of size 42m x 17m x 3.6m clear height + Eaves height, plinth height 0.15m (FFL matching with adjoining Dispersal), etc with Pre-Engineered Building structure (PEB), as per specification given in Particular Specifications, with sloping galvalume sheet roofing (0.5mm thick profiled pre-colour coated galvalume sheet roofing), RCC (M-30 design mix) foundation and pedestal, Galvalume sheet wall cladding, bird proofing, Telescopic motorised hangar sliding door shutter with track rail, also including necessary strenghtening for seismic zone -III, (Excluding Flooring of CPA Hanger Portion) complete all as specified and directed and as shown on drawings.
Note for item No 1.21 to 1.22- The PEB Structure shall be designed, fabricated, erected and commissioned through PEB Approved manufacturer given in Clause no 18.1 of Particular Specifications. The Design of PEB Structure shall be vetted from IIT/NIT further shall sent to Accepting Officer (E2 (Des)) for checking and approval at no extra cost to the department and rate for same shall be included in the Lumpsum quoted by the bidder.
Design, Fabrication and Construction of Annexe building on both side and rear side of Maintenance hangar height 3.2m minimum, in Light Gauge Steel Framed (LGSF) Structure,as per specification given in Particular Specifications, including 0.5mm thick profiled pre-colour coated galvalume sheet roofing, internal & External walls with 150mm thick Expanded Polystyrene (EPS) Core Panel System, supporting structure of Loft Tank in toilet, RCC (M-25 design mix) foundation and plinth, Flooring as given in Sch of finishes, Sound proofing to briefing Room and Crew Room including necessary strenghtening for seismic zone -III, complete all as specified and directed as shown on drawings.
Design, Fabrication and Construction of Annexe building both side of CPA Hangar height 3.2m minimum, in Light Gauge Steel Framed (LGSF) Structure,as per specification given in Particular Specifications, including 0.5mm thick profiled pre-colour coated galvalume sheet roofing, internal & External walls with 150mm thick Expanded Polystyrene (EPS) Core Panel System, supporting structure of Loft Tank in toilet, RCC (M-25 design mix) foundation and plinth, Flooring as given in Sch of finishes including necessary strenghtening for seismic zone -III, complete all as specified and directed as shown on drawings.
Design, Fabrication and Construction of BFG room height 3.2m minimum, in Light Gauge Steel Framed (LGSF) Structure,as per specification given in Particular Specifications, including 0.5mm thick profiled pre-colour coated galvalume sheet roofing, internal & External walls with 150mm thick Expanded Polystyrene (EPS) Core Panel System, supporting structure of Loft Tank in toilet, RCC foundation and plinth, Flooring as given in Sch of finishes including necessary strenghtening for seismic zone -III, complete all as specified and directed as shown on drawings.
Note for item No 1.24 to 1.26- The LGSF Structure shall be designed, fabricated, erected and commissioned through Approved manufacturer given in Clause no 19.1 of Particular Specifications. Such firm must have obtained "Performance Appraisal Certificate" for LGSF/EPS core wall system from Building Material and Technology Promotion Council (BMTPC). The Design of LGSF Structure shall be vetted from IIT/NIT further shall sent to Accepting Officer (E2 (Des)) for checking and approval at no extra cost to the department and rate for same shall be included in the Lumpsum quoted by the bidder.
Design, Fabrication and Construction of Car/Scooter parking shed of Structural steel tubular posts and trusses structure in permanent specification height 3.2m minimum with RCC foundation and plinth, with 0.5mm thick profiled pre-colour coated galvalume sheet roofing, Flooring, etc including necessary strenghtening for seismic zone -III, complete all as specified and directed as shown on drawings.
Total amount of Sch 'A' Part-II (Internal water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electric Supply)
Total amount of Sch 'A' Part-VI (Road, Path, Hardstanding and Culverts)
Total amount of Sch 'A' Part-VII (Sewage Disposal)
Total amount of Sch ‘A’ Part VIII (Area drainage)
Total amount of Sch ‘A’ Part IX (Boundary wall, fencing & steel gate)
Total amount of Sch ‘A’ Part X (Lightning Protection)
Total amount of Sch ‘A’ Part XI (Fire Fighting)
Total amount of Sch ‘A’ Part XII (Excavation, Earthwork & Site Clearance)
SCH 'A PART XIII (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Provide Prime Cost Sum of Rs. 25 Lakhs for the following:- Design, Supply, Installation, testing and commissioning of following items all as specified and directed. (a) Fire detection and alarm system complete with fire alarm panel complying with BSEN 54 as per required loop panel of capacity from required detectors & modules including copper wiring, hooters, siren, detectors, response indicatores, mannual call points including heat and smoke detectors all as per ISO 7240-14: 2013 all as specified and directed. (b) Sprinkler system complete with sprinklers/ rossett plate/ flexible metal hose of 1 mtr length/ water flow detectors. Sprinkler sys should be as per IS 15105 : 2002 including requred size of pipes and fixing accessories all as specified and directed. (c) Design of water supply headers in pump house building and connected items such as pressure switch/ pressure gauge/ panel etc all as specified and directed.(d) Balance items other than schedule which are considered necessary for fire hydrant system. (e) Incorporation of CFEES reccommendations while designing complete system. (f) The complete system shall be got designed from OEM/ approved consutant of fire fighting system as per relavent IS and NFPA codes.The design shall be got vetted from IIT/NIT or any authorised Govt Institute.
Note :(i) Prime cost sum shall be got expended wholly or partly and work to be executed by the persons / agency nominated by Accepting Officer and ordered by GE as per Condition 5 of IAFW - 2249, GCC. (ii) The amount of Prime cost sum of Rs. 25,00,000.00 indicated above is Prepriced by MES and the Add/Deduct percentage (%) will be indicated under col 6 of this BOQ over the sum inserted by MES and bidders are requested to quote his lumpsum under col 13 in such a way that the percentage (%) worked out shall not be more than 15% (Fifteen Percent). In case the percentage worked out more than (+) 15% over the lumpsum amount inserted by MES in that case the percentage (%) will be corrected to ensure as (+) 15% only. Also refer Condition 5 of IAFW-2249 (General Condition of Contracts).
M & L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 x 10 sq. mm + 2 x 10 sq.mm earth continuity conductor to be drawn through and including ERW steel conduit conduit not less than 32 mm dia medium grade fixing on wall surfaces/ roof / floors complete all as specified and directed. Note:- (i) Four wires of 10 sq. mm and two wire of 10 sq. mm and one run of steel conduit shall be measured as one unit. (For 3 phase, 380V x 25 A - 03 nos and 3 phase, 380V x 36 A - 10 nos power circuit in Maintenance hanger / CPA / ALRS, AGCS, GES PAD)
M & L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 x 6 sq. mm + 1 x 6 sq. mm earth continuity conductor to be drawn through and including ERW steel conduit not less than 32mm dia medium grade fixing on surfaces of walls / roof / floors complete all as specified and directed. Note :- (i) Four wires of 6 sq.mm and one wire of 6 sqmm and one run of steel conduit shall be measured as one unit.(for 3 phase, 380V x 16 A - 03 nos and 3 phase, 380V x 20 A - 03 nos power circuit in CPA PAD)
M & L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 x 6 sq. mm + 1 x 6.sq. mm earth continuity conductor to be drawn through and including ERW steel conduit not less than 25 mm dia medium grade fixing on wall surfaces / roof / floors complete all as specified and directed. Note:- (i) Two wires of 6 Sq mm and one wire of 6 Sq mm and one run of steel conduit shall be measured as one unit.(for 1 phase, 230V, 10A - 8 nos and 16A - 14 nos power circuit in Maintenance Hanger)
M & L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 x 4 sq mm + 1 x 4 sq.mm, earth continuity conductor to be drawn through and including ERW steel conduit 25 mm dia medium grade surface on walls /roof / floors complete all as specified and directed. Note:- (i) Two wires of 4 sq. mm and one wire of 4 sq. mm and one run of steel conduit shall be measured as one unit. ( For flood light fitting in Maintance Hanger / CPA (PAD) / Gen. shade / ALRSA, AGCS, & GES PAD)
M & L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 x 2.5 sq. mm + 1 x 2.5sq. mm earth continuity conductor to be drawn through and including ERW steel conduit not less than 25 mm dia medium grade fixing on wall surfaces / roof / floors complete all as specified and directed. Note:- (i) Two wires of 6 Sq mm and one wire of 6 Sq mm and one run of steel conduit shall be measured as one unit.(for 1 phase, 230V, 10A - 8 nos and 16A - 14 nos power circuit in Maintenance Hanger)
Sub main wiring power circuit using PVC insulated unsheathed, stranded copper conductor cable 2 x 10 sq mm + 1 x 10 sq.mm earth continuity conductor to be drawn through and including stove enamelled steel conduit 25 mm dia medium grade conceled in walls /roof / floors complete all as specified and directed. Note :- (i) Two wires of 10 Sq mm and one wire of 10 Sq mm and one run of steel conduit shall be measured as one unit. (For 1 phase, 230 V, 20A - 30 nos, 30A - 4 nos and 35A - 4 nos power circuit in Maintance Hanger / CPA (PAD) / Gen. shade / FOL shade / ALRSA, AGCS, & GES PAD)
Supply, fixing and testing of flood light maximum 150W LED, minimum system lumen output of 16500 lm. The luminnare should have colour temperature of 5700/ 6500K and THD<10% CRI> 70. The luminaire shall meet IP66 ingress protection and impact resistance of IK07 and luminaire housing should made of pressure die-cast aluminium and itegrated PC Lens. The luminaire should have the features of high voltage 10 kV external surge protection long life of LEDs 50000* BH (L70), integrated potted LED driver offers comfortable softlight, high durability, Driver safety requirement standards as per IS 15885-2 -13. Test certificate to be submitted. Photobilogical safety norms as per IS 16108. Cat part No JETAIRISFLS150WLED757PSYMLTG of Havells or equivalent in makes listed in Appendix 'C'.
S & F VTPN MCCB DB prewired made of sheet metal powder coated suitable for surface mounting with 250A copper bus bar for each phase with 2 neutral bar & 2 earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCCB & outgoing MCBs with IP-54-IK09 protection grade , 415Volts TPN with 12 way Double door all as specified & directed.
S & F VTPN MCCB DB prewired made of sheet metal powder coated suitable for surface mounting with 250A copper bus bar for each phase with 2 neutral bar & 2 earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCCB & outgoing MCBs with IP-54-IK09 protection grade , 415Volts TPN with 4 way Double door all as specified & directed
S & F MCB DB made of sheet metal powder coated with acrylic door suitable for surface mounting with 100A copper bus bar for each phase with neutral bar & earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCB & outgoing MCBs with IP-43-IK09 protection grade , 415Volts TPN with 12 way Double door as per Cat Pt No 507622 of legrand or equivalent in makes listed in Appendix 'C'. all as specified & directed
S & F MCB TP 63 Amps , 415 Volts, 16KA, 3 Pole as per Cat Part No 408768 of Legrand or equivalent in makes listed in Appendix 'C.
MCB TP 32 Amps , 415 Volts, 16KA, 3 Pole as per Cat Pt No 408765 of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps as per Cat Pt No 408609 for 6 A, 408612 for 10A, 408614 for 16 A, 408615 for 20 A, 408616 for 25 A, 408617 for 32A of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40-63 Amps as per Cat Pt No 408618 for 40 A, 408619 for 50A & 408620 for 63 A of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps as per Cat Pt No 408587 for 6 A, 408590 for 10A, 408592 for 16 A, 408593 for 20 A, 408594 for 25 A, 408595 for 32A of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps of makes listed in Appendix 'C.
S & F RCCBs, four pole of current capacity 100A with sensitivity 100mA of makes listed in Appendix 'C.
S & F MCCB TPN, 4 Pole 125 A, 415 V, breaking capacity 25 KA, adjustable tripping, suitable for isolation as per Cat Pt of 420016 of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCCB TPN, 4 Pole 63 A, 415 V, breaking capacity 25 KA, adjustable tripping, suitable for isolation as per Cat Pt of 420016 of Legrand or equivalent in makes listed in Appendix 'C.
S & F MCCB TPN, 4 Pole 40 A, 415 V, breaking capacity 25 KA, adjustable tripping, suitable for isolation as per Cat Pt of 420016 of Legrand or equivalent in makes listed in Appendix 'C.
S&F MCCB TPN 100 Amp, 4 pole, 415 volts 25 KA with sheet metal enclosurre of size 30cmx 45cm complete all as specified and directed.
S&F MCCB TPN 50-63Amp, 4 pole, 415 volts 16 KA with sheet metal enclosurre of size 30cmx 45cm complete all as specified and directed.
S & F earth enclosure with 3 pin,neutral & earth plug socket as per IEC 61439- 3 supplied with neutral link & earth, suitable for mounting on surface with provision of mounting modular device complete with MCB TP 63 amp, flush mounting type all as specified for 3 phase 380 V and as per Cat Pt No 507864 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 3 pin,neutral & earth plug socket as per IEC 61439- 3 supplied with neutral link & earth, suitable for mounting on surface with provision of mounting modular device complete with MCB TP 32 amp, flush mounting type all as specified for 3 phase 380 V and as per Cat Pt No 507862 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 3 pin,neutral & earth plug socket as per IEC 61439- 3 supplied with neutral link & earth, suitable for mounting on surface with provision of mounting modular device complete with MCB TP 20amp, flush mounting type all as specified for 3 phase 380 V and as per Cat Pt No 507817 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 2 pin, neutral & earth plug socket as per IEC 61439- 3 supplied with, suitable for mounting on surface with provision of mounting modular device complete with MCB DP 10amp, flush mounting type all as specified and as per Cat Pt No 507810 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 2 pin, neutral & earth plug socket as per IEC 61439- 3 supplied with, suitable for mounting on surface with provision of mounting modular device complete with MCB DP 16amp, flush mounting type all as specified and as per Cat Pt No 507860 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 2 pin, neutral & earth plug socket as per IEC 61439- 3 supplied with, suitable for mounting on surface with provision of mounting modular device complete with MCB DP 20amp, flush mounting type all as specified and as per Cat Pt No 507814 of Legrand or equivalent in makes listed in Appendix 'C.
S & F earth enclosure with 2 pin, neutral & earth plug socket as per IEC 61439- 3 supplied with, suitable for mounting on surface with provision of mounting modular device complete with MCB DP 32amp, flush mounting type all as specified and as per Cat Pt No 555454 of Legrand or equivalent in makes listed in Appendix 'C.
S & F for TV socket modular type complete of make listed in Appendix 'C.
S & F for telephone socket modular type 2G complete of make listed in Appendix 'C.
Supply & fix energy saving 32W, 375 RPM air dilivery 220 Cum/min with IR remote, ceiling fan, 1200 mm (48") sweep, 5 star rating BEE mark (after assembling the same) with the fan hook/box and connecitng up complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan. Make : Bajaj Cat No KASSEL STAR or equivalent in makes listed in Appendix 'C', complete all as specified and as directed.
Supply & fix exhaust fan 225mm sweep, 1400RPM, single phase, heavy duty including fixing of mounting frame in the round hole cutting in wall and making good the surfaces, fixing by means of rugged bolts, nuts and washers etc on the round hole cut in wall, including three core copper conductor flexible cord of 0.5sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply including GI louver shutters. Make listed in Appendix 'C', complete all as specified and as directed.
Supply & fix linear 550- 600 mm tiltable surface mounted 10W to 12W, Decorative LED Batten Fixture consisit of Aluminum Extrusion housing with PC Diffuser , LED Fixture System wattage of 10 W / 12W , 140 V -260 V AC, System Lumen Output min 1000 Lumen in 10 W and in 1200 lumen in 12W with 5700 - 6500 K CCT with PF > 0.95 and with < = 15 % THD , with Min 2.5 KV Surge protection in Built and complete LED fixture with BIS R mark and R registration No. of make Havells Cat No LHEXACP7IN1W010 or any make as listed in Appendix 'C', complete all as specified and as directed.
Supply & fix LED light fitting out door type building security light 40W including brackets made out of 32mm dia GI tubing, 1.5m length with bend duly welded with two Nos of brackets made out of 40x6mm thick Flat Iron with nuts and bolts, decorative LED Batten Fixture consisit of extruded Aluminum Extrusion housing with PC Diffuser , LED Fixture System wattage of 36 W / 40W , 140 V -260 V AC, System Lumen Output min 3960 Lumen in 36 W and in 4400 lumen in 40W with 5700 - 6500 K CCT with PF > 0.95 CRI >= 80 and with < = 15 % THD , with Min 2.5 KV Surge protection in Built and complete LED fixture with BIS R mark and R registration No. of make listed in Appendix 'C', complete all as specified and as directed.
Supply, installation, testing and commissioning of high bay light maximum 150W LED, minimum system lumen output of 22500lm. The luminnare should have colour temperature of 5700/ 6500K and THD<10% CRI> 70. The luminare shall meet IP65 rating, IK07 and liminare housing should made of pressure die-cast aluminium and itegrated PC Lens. The luminaire should have the features of high voltage surge protection upto 4KV, long life of LEDs 50000* BH (L70), intgrated potted LED driver offers comfartable softlight, high durability, Driver safety requirement standards as per IS 15885-2 -13.Test certificate to be submitted . Photobiological safety norms as per IS 16108. Test certificate tu be submitted : certification LM 79 for Luminaire and LM 80 for LED source all as per Havells Cat No SAUCER GENXPROHBP150WLED757P90DBOLTG of make listed in Appendix 'C', complete all as specified and as directed.
Supply, installation, testing and commissioning of maximum 34W backlit type 595mmx595mm recess mounting LED luminaire equipped with CRCA powder coating housing, high transmittance PF diffuser with symmetric light distribution , minimum system lumen output of 4200 lm, THD<20% CRI> 80. CCT 5700/6500K, high surge protection upto 3.5KV,and operating temperature 0°C to +45°C, Driver safety requirement standards as per IS 15885-2 -13.Test certificate to be submitted . Photobilogical safety norms as per IS 16108. Test certificate to be submitted : certification LM 79 for Luminaire and LM 80 for LED source all as per Havells Cat No PLANO 02X2 PLR 34W LED 857S or equivalent of make listed in Appendix 'C', complete all as specified and as directed.
Supply, installation, testing & commissioning of maximum 10W LED recessed mounting circular LED down light luminaire with die cast aluminium housing in white powder coating finish, System Lumen Output min 1000 Lumen in 10 W , THD<10%, CRI>80, CCT=5700/6000K, high surge protection 3.5KV and operating temperature 0°C to +45°C , Driver safety requirement standards as per IS 15885-2 -13.Test certificate to be submitted . Photobiological safety norms as per IS 16108. Test certificate to be submitted : certification LM 79 for Luminaire and LM 80 for LED source as per Havells Cat No JETA IRIS FLS 150 W LED 757 PSYMLTG or equivalent of make listed in Appendix 'C', complete all as specified and as directed.
Supply, installation, testing & commissioning of maximum 20W LED IP 20 batten with extruded aluminium housing in Anodised finish, minimum system lumen 2200 Lumen in 20 W , THD<20%, CRI>80, CCT=6500K, high surge protection 3.5KV and operating temperature 0°C to +45°C, Integrated LED driver offers comfortable soft light, high durability. Driver safety requirement standards as per IS 15885-2 -13.Test certificate to be submitted . Photobiological safety norms as per IS 16108. Test certificate to be submitted : certification LM 79 for Luminaire and LM 80 for LED source Havells Cat No LUMILINEPLUSBS 20W LED 865 SPCSS or equivalent of make listed in Appendix 'C', complete all as specified and as directed.
Supply and fix MS powder coated perforated type cable trays 1.6mm thick of size 50mmx50mm and fixed with required arrangement complete all as specified and as directed.
Supply and fix MS powder coated perforated type cable trays 1.6mm thick of size 75mmx50mm and fixed with required arrangement complete all as specified and as directed.
Supply and fix MS powder coated perforated type cable trays 1.6mm thick of size 100mmx50mm and fixed with required arrangement complete all as specified and as directed.
Supply and fix MS powder coated perforated type cable trays 1.6mm thick of size 200mmx50mm and fixed with required arrangement complete all as specified and as directed.
Supply & fix wall mounted air circulator fan heavy duty of size 750mm, single phase 230V, 50Hz prewired. The aerodynamic designed blade for higher air dilivery and minimum noise level, with oscillation upto 90° and sturdy brazed wire 940 rd with powder coating , confirming to IS 2997: 1964 of make listed in Appendix 'C', complete all as specified and as directed.
M &L for submain wiring with 4 runs of 16 Sqmm single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables drawn through concealed/surface conduit and including PVC conduit heavy grade with and including 2 runs of single core 16.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. (For Power DB's)
M &L for submain wiring with 4 runs of 10 Sqmm single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables drawn through concealed/surface conduit and including PVC conduit heavy grade with and including 2 runs of single core 10.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. (For Power DB's)
M &L for submain wiring with 4 runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables drawn through concealed/surface conduit and including PVC conduit heavy grade with and including 2 runs of single core 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. (For Power DB's)
S&F LED flame proof 1x20watt LED tube light fixtures luminaire complete suitable for illuminating hazardus area laden with gases or vapours all as per Cat No EXTN1LT8-16/20 of Crompton Greaves or equivalent in makes listed in Appendix 'C', complete all as specified and as directed.
M & L for point wiring complete with and including single core PVC FRLS insulated sheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) ISI marked, 1100 volts grade drawn through and including heavy grade ERW steel conduits 20 mm or higher dia as required at site, surface mounted including all conduit accessories/fittings/ junction boxes /inspection covers etc; of heavy grade, ISI marked and fixed on walls by means of brass screws and sunk/ cupwashers, for mounting of switches, sockets fan regulators etc, including 1.5 Sqmm (22/0.30 mm) PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed.
S&F flame proof distribution board sheet metal enclosure, double door, factory made, fixed flush with wall inside the nitches for mounting MCBs 230 Volts with bus bars with front openable cover 4 way 230V with 100 A bus bar consumer unit complete with flame proof MCBs all as specified and as directed.
S&F floor/wall mounted grounding point for removal of electro static electrical accummulation. The electrodes shall be made out of copper rod of dia 15.9mm(5/8 in) or longer metal rod driven atleast 1.5m (5 feet) in to ground including connecting earth electrode copper strip with s/s steel nut bolts , washers and with copper brazing as directed and specified.
S&F copper static bus bar of size 2 inches by 1/4 inches(51/6mm) installed on wall with stand off insulators and stainless steel nut bolts and washers, complete all as specified and as directed.
Supply, installing, connecting , testing and commissioning storage type water cooler 80 Litrs capacity and cooling capacity 40 Litrs per Hour, based on eco friendly gas R-134a, complete body made of food grade stainless steel with two taps ( both cold water) complete with inlet drain pipe connection with inbuilt float valve all as directed at site including extending drain out pipe to the nearest drain system complete of make Blue Star/Usha/Voltas, all as specified and as directed.
Supply and fix Voltage stabiliser for automatic operation, single phase, naturally cooled, indoor wall mounted type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+)/(-) 2.5 % and of capacity 1.0 KVA, 230 V, 50 Hz all as specified and as directed.
Supply and fix Inverter spilt air conditioner electric driven single phase of capacity 1.5 TR, BEE 5 Star rated (latest) with ISEER 4.51 W/W complete with anti dust filter, high ambient cooling,control remote, standerd copper cable of appropriate size of 5 mtr length up to power point, initially filling of refrigernat and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commision as recommended and directed. Specification of air conditioner is as under :
Tonnage : 1.5 TR
Refrigerent Gas : R 32 (Non CFC)
Power Supply : 230 Volts/50Hz single phase, wide operating voltage range 145 to 270 V.
Condensor Coil : Copper
Connected pipe : 5Mtr
Rated cooling Cap : 5200 Watt
Connected Cable : Copper with appropriate size 3 mtr
Air Flow Volume : 930 (CMH)
Model No : Voltas Split A/C 185 V CZP (R32) or equivalent of make listed in Appendix 'C',.
Supply and fix inverter spilt air conditioner electric driven single phase of capacity 2 TR, BEE 5 Star rated (latest) with ISEER 3.85 W/W complete with control remote, standerd copper cable of appropirate size of 5 mtr length up to power point, initially filling of refrigernat and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commision as recommended and directed. Specification of air conditioner is as under :
Tonnage : 1.5 TR
Refrigerent Gas : R 32 (Non CFC)
Power Supply : 230 Volts/50Hz single phase, wide operating voltage range 145 to 270 V.
Condensor Coil : Copper
Connected pipe : 5Mtr
Rated cooling Cap : 6050 Watt
Connected Cable : Copper with appropriate size 3 mtr
Air Flow Volume indoor : 950 (CMH)
Model No : Voltas Split A/C 243VH SZS(R32) or equivalent of make listed in Appendix 'C',.
Material & Labour for fabrication and fixing of MS stand made out of MS angle/ channel for fixing of outdoor unit of split AC with suitable size of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc as in brackets of outdoor unit of AC duly painted by 01 coat of red oxide and two coats of synthetic enamelled paint, conforming to Fe 410 -W (GdeE- 250) quality A all as specified and as directed.
Supplying and fixing of Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc.including pipe fittings such as bends, elbows, union, tees, reducing tees, sockets, plugs hose clips and fixing with walls with saddles, wall clips, hooks for outlet drain of each AC to main drain pipe of size of 20mm all as specified and as directed.
Supplying and fixing of Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc.including pipe fittings such as bends, elbows, union, tees, reducing tees, sockets, plugs hose clips and fixing with walls with saddles, wall clips, hooks for outlet drain of each AC to main drain pipe of size of 50mm all as specified and as directed.
M& L for Earthing complete with copper earth plate electrode 300 x300 x 3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including copper earth strip earthing strip of 20x3mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to earthing test point GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32x6 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Material & labour for chemical earthing for plants & equipments as per IS 3043 and IEC 62561 standards. The chemical electrode shall be of non corrosive, copper pipe with 3 m length. The electrode shall be filled with highly conductive & non corrosive mixtures so that inner strip or pipe will never corrode and provide lowest possible resistance. The minimum dia of the outer pipe shall be 40mm all as directed and specified.
M & L for river sand cushioning (dry) in trenches/ ducts for protection of UG cables (below, above and around the UG cable laid in trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. . . Note-Punned thickness will be considered for payments purpose.
M& L for horizontal drilling/ boring under road for passing of cable pipe/ water supply pipe upto and including 80mm bore all as specified and directed.
M& L for horizontal drilling/ boring under road for passing of cable pipe/ water supply pipe over 80mm bore but upto 200mm bore all as specified and directed.
Supply, installation, testing and commissioning of plinth mounted sted down outdoor type energy efficient level -2 distribution transformer HT 11 KV, 3 Phase, LT 433 V, 4 wire capacity 400 KVA , copper wound,oil immersed laminated iron core naturally cooled with external cooling tubes, type delta connected on primary HT side and star connected on secondary LT side in accordance with vector symbol group DYN -11 (Vector ground - 4) with natural brought on secondary (LT) side & having tapping in equal steps of 2.5% from (±) 5% to (±) 7.5% to be changed by means of hand operated off load tap changing gear, so as to change/ correct LT voltage on secondary side confirming to IS 1180 Part- I 2014 including provision of all neccessary standard fittings and mainly comprising of the following :
(a) One cable box on HT side (Primary side) consisting of 3 Nos porcelain bushing with copper roads complete with nuts & bolts.
(b) One cable box on LT side (Secondary side) consisting of 4 Nos porcrlain bushing with copper rods complete with nuts & washer.
(c) Oil conservator oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent (Silica Gel)
(e) Explosion vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs, oil filling hole with cap/ plug air release valve plug & 4 Nos plain solid cast steel detachable rollers.
(f) One 100mm dia dial type thermometer, vapour pressure type, having range 0- 120 degree Celsius having maximum temprature reading indicator with resetting.
(g) Two earthing terminals on tank to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing body.
(h) Rating plate & terminal marking plate.
(j) Extra bushing for neutral, in the LT cable box for providing independant set of earthing for neutral.
(k) First filling of transformer oil, IS- 335 Marked within (Make - Savita/ Power link) filter & tested upto K0 KV dielectric strength at 2.5 mm air gap between electrodes.
(l) PCC foundation of transformer will be provided.
(m) Supply and fixing chain link fencing including line wires, any mesh, 100mm size and 4mm dia type of standards, rails, straining bolts etc including provision of binding wire and all connected items.
(Note : PCC foundation for transformer and chain link fencing with its connected items will measure and paid separately)
Material and labour for platform suitable for the transformer of capacity 200 KVA with PCC 1:4:8 type D-2 using 40mm graded coarse stone aggregates, 150mm thick in foundation, RR Stone masonry work in CM 1:6 , pointing to stone masonry in cement mortar 1:4 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel over and including moorum filling. The platform shall be of 3.0x 3.0 x 1.5 mtr height above ground level and of adequate size leaving minimum 300 mm all around the transformer for movements. All as shown on drawing No CEPZ/98/TD/6 sheet No 2/2 of dated 21 Apr 98 except size of Plateform.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel wire armoured, earthed, electric power cable (heavy duty) with stranded aluminium couductor, 11000 volts grade, of size 3 core 95 sq mm, HT UG cable laid in tranches/through GI pipe/fixed along with pole complete all as specified & directed.
S&F cable route indicator made out of CI circular disc engraved embossed HT cable, 100 mm dia , 10 mm thick fixed on MS round bar of 10 mm dia 60 cm long duly painted with primer and synthetic enamel paint. Indicator shall be embedded in PCC block of size 40cmx40cmx40 mm and indicator shall be 20 cm above the ground level complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of 200 kVA DG set complete 415V, 50Hz, AC with acoustic enclosure as per CPCB-II norms directly coupled to alternator brushless type, electronic AVR and Governor, voltage regulation ±1% complte with Std control panel with automatic ON/OFF on main failure (AMF) panel with all standerd accessories as per IS and norms having all type of meters, fuel tank, fuel line system, foundation, etc of capacity upto 200 kVA suitable for the purpose of synchornization of DG sets through 3.5 core 240sqmm cable and all as per the specifications given below all as specified and as directed by Engr-in-Charge
Diesel Engine : Diesel engine having minimum output 243 BHP with prime rated power as per ISO:8528/1, speed 1500 RPM, six cylinders, 4 stroke radiator cooled engine sull authority Electronic Engine Well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator air to air after cooling and optimised turbocharger for increased altitude capabilities, electric starting system with 24 volt DC electric starting motor, electronic governor, full automatic electronic fuel injection system with electronic governing, standard integral set mounted radiator system, full flow spin on lube oil filter, plate type lube oil cooler, battery charging alternator, hospital grade silencer suitably optimised to meet stringent noise emission standards laid down by MoEF/CPCB
Alternator : PMG Alternator of rating 200 kVA/160 kW, 415 volt AC 3 phase 4 wire system on 50 Hz frequency and speed 1500 RPM at power factor 0.8 (Lag) having class "H" insulation for both rotor and stator with IP23 screen protected, drip proof and conforms to BS 5000, IS 4722and IEC 34 standards and brushless, self excited, self regulated excitation and suitable for a permissible overload of 10% for one hour in 12 hrs testrun, ±1% voltage regulation and all as per the recommendations of the manufacturer and alll as specified and as directed by Engr-in-Charge
DG Engine control panel : Supply, install, test and commissioning of electronic DG control panel to be mounted inside the acoustic enclosure of DG sets with following basic features :
(a) Graphic LED backlight LCD.
(b) Multiple language support
(c) Amp Sentry TM protection - for true alternator overcurrent protection
(d) Digital power Transfer Control (AMF) provides load transfer operation in open transition, closed transition, or soft (ramping) transfer modes
(e) Extended paralleling (Peak Shave/Base load) regulates the genset real and reactive power output while paralleled to the utility. Power can be regulated at either the genset or utility bus monitoring point.
(f) Digital frequency synchronization and voltage matching
(g) Isochronous Load Share
(h) Droop KW and KVAR control
(i) Real time clock for fault and event time stamping
(j) Exerciser clock and time of day start/stop initiate a test with or without load or a Base load or Peak Shave session.
(k) Digital Voltage regulation three phase full wave FET type regulator capable with either shunt or PMG system.
(l) Genset monitoring and protection
(m) Utility/AC Bus metering and protection.
(n) 12 V DC Battery interconnecting to customer equipment.
ACCOUSTIC ENCLOSURE : Specifically designed to meet stringent MoEF/CPCB norms of 75 dBA@1mtr at 75% load under free field condition. The accoustic enclosure is made of CRCS sheet in munsel green shade and a structural/sheet metal base frame painted in black.
The hot chamber of the canopy shall be properly insulated by mineral wool and aluminium foil to prevent excess heat radiation.
BASE FRAME : The Diesel engine and alternator shall be perfectly aligned and assembled dynamically balanced on a sturdy, fabricated, welded construction, channel iron base frame. Base frame shall have lifting provisions and predrilled holes suitable for grouted foundation.
AMF Panel : AMF panel with incoming MCCB of 4 pole, 415V, 400 Amps and change over switch with 415 V ± 10% suitable capacity as reccommended by manufaturer with main power supply & DG Set power supply indication with voltmeter & Ammeter and miltifunction meter for various operations as reccommended by manufaturer & push button for stop, reset and acknowledge with IP 52 degree protection as per IS: 12063 and shall be provided with automatic start facility to make it possible to take full load within 30 seconds of main power supply failure. Testing facility for automatic opertaion of DG Set shall be provided.
Note : Engine shaft suitable for generating application and capable of giving output of 200 Kva for coupled alternator under NTP conditions, complete with following :
(i) Suitable fuel pump and fuel piping of size as recommended by manufacturer (ii) Fuel filter with water separator and filter element. (iii) Lub - Oil filter with filter element. (iv) D.C. starter 12 Volts. (v) Maint free storeage type Battery of suitable Voltage and Ampere hours as recommanded by the manufactures. (vi) Industrial type silencer including MS exhaust pipe lagged with asbestores rope of 5 mm ida all around and over this 50 mm thick flat mineral wool inshulter sheet cover and then, 24 SWG Aluminium sheet cladding with rivets all over the lenght. (vii) Support/ fixing arrangement for muffler with cilling through anti vibration pads. (viii) Engine overspeed stop/ trip switch. (ix) Radiator with fan. (x) Dynamo for battrey charging. (xi) Correosion inhibitor coolant. (xii) Engine control panel electronic, digital dispaly type consisting of bty Voltage indicator, lub oil temp and pressure guages, coolant water temp guage, RPM indicator-cum-hour meter etc. (xiii) Safety controls for alarm due to high water temp (HWT) and low lub oil pressure (LLOP) (xiv) Any other devices/ accessories recommended/ supplied by the manufactures as standard eqpt. (xv) Skid : The engine and alternator shall be coupied, aligend and mounted on a specially designed common base frame fabricated from MS channels of suitable corss sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads. Make : Anti vibration pads :- Dunlop/ Polybond of required size and numbers as recommended by the manufactures for mounting of 200 KVA DG set.
(xvi) Diesel tank of adequate capacity for 12 hrs continous run on full load with calibrated scale f(fuel level indicatorf) dip stick, fuel inlet/ outlet, Air vent, drain plug and inlet arrangement for direct filling, including suitable size gun metal gate valve in outlet, tank shall be fitted all as per manufacture's requirements/ specification. (xvii) Acoustic enclosure with canopy cover shall be provided as per latest CPCB norms. (xviii) Industrial type silencer including MS exhaust pipe lagged with asbestors rpe of 5 mm dia all around and over this 50 mm thick flat mineral wool insulator sheet cover and then, 24 SWG Aluminimum sheet cladding with reivets. all over the length. (xix) Support/ fixing arrangement for muffler with ceillign through antt vibration (xx) Documents : Three sets of fwg docus :- Manint and Ops manuals for enigne and alternator, spare parts catalogue, warranty/ test certificates, schematic diagrams of control panels. (xxi) Connecting cable in new panel with required accessories etc complete. (xxii) Optional items : list of tools and as per manufactures recommended lists, duly proced, item wise. (xxiii) Contractors shall satisfactorily conduct load test of each DG set for 12 hrs including run on 10% overload for 1 hrs. (xxiv) Testing eqpt will be arranged by the Contractor under his own arrangement and cost. Make of DG set :- Any of the make listed in Appx 'C'.
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of following sizes :-
(a) 240 sqmm x 3.5 core
(b) 150 sqmm x 3.5 core
(c) 70 sqmm x 3.5 core
(d) 50 sqmm x 3.5 core
(e) 25 sqmm x 4 core
(f) 16 sqmm x 4 core
(g) 10 sqmm x 2 core
Supply & fix LED Avation / obstruction light, SAIL LED Single fitting suitable for Maintenance Hall / Hanger and Covered Parking area all as specified and directed. Make listed in Appendix 'C'
Supply, installation, test and commissioning (CPRI Approved) factory fabricated, out door type, LT Feeder Pillar Box made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection dust and vermin proof , double door with both side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with 50 X 50 X 6mm mild steel angle iron frame and 750 mm above the normal gound level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after Installation including complete all as specified and comprising of the following : (Location - Near transformer)
INCOMING :
(a) Bus bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 1000 Amps with colour coding in separate sheet steel enclosure.
(b) Air circuit breaker 800 Amps, 4 Pole,50 Ka, fixed type LT 415 V AC grade having microprocessor based release for over current and earth fault protection and interlock trip push button complete IS 2516 marked - 01 No (For incoming)
(c) Digital multi function panel mounted meters for energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS 13779:99/IEC 61036, CL 1.0, operating temperature -10 to +55 ˚C, relative humidity 95% non condensing, 96 X 96 X 86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mm X 4.8 mm, Protection index IP54 with all necessary CTs, PTs and instrument fuses and wiring.- 1 No
OUTGOING :
(a) High breaking capacity MCCB 630 Amps, 50 Hz, 415 V rupturing capacity 50 KA - 01 No ( O/G New hanger)
(b) MCCB with thermal based release, 3 pole, 200 Amps, 50 Hz, 35 KA- 04 No (O/G ) (i) CPA (ii) APFC panel (iii) Spare
(c) MCCB with thermal based relay, 3 pole, 32 Amps, 50 Hz, 415 V rupturing capacity 36 KA - 02 Nos (i) Street lights (ii) Spare
(d) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos
(e) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(f) Fine wiring with single core copper conductor cable for instruments / indicating lamps - 01 Job.
(g) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 , rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply, installation, test and commissioning (CPRI APPROVED) factory fabricated, out door type, LT feeder piller box made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection dust and vermin proof , double door with both side opening including noprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50 X 50 X 6mm mild steel angle iron frame and 750 mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and tesing after installation including complete all as specified and comprising of the following : (Location - Near Proposed Maintenance Hall / Hanger)
INCOMING :
(a) Bus bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 800 Amps with colour coding in separate sheet steel enclosure.
(b) High breaking capacity MCCB 630 Amps, 50 Hz, 415 V rupturing capacity 50 KA - 01 No
(c) Digital multi function panel mounted meters for energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS 13779:99/IEC 61036, CL 1.0, operating temperature -10 to +55 ˚C, relative humidity 95% non condensing, 96 X 96 X 86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mm X 4.8 mm, Protection index IP54 with all necessary CTs, PTs and instrument fuses and wiring.- 1 No
OUTGOING :
(a) MCCB with thermal based release 3 pole, 250 Amps, 50 HZ, 35 KA - 03 No (O/G) (i) Pannel-1 Hanger, (ii) Pannel -2 Hanger , (iii) Spare.
(b) MCCB with thermal based release 3 pole, 200 Amps, 50 Hz, 35 KA - 02 Nos (i) Pump House (ii) Spare
(c) MCCB with thermal based release 3 pole, 32 Amps, 50 Hz, 25 KA - 03 Nos (i) Sec Lights (ii) GTD Ramp (iii) Spare
(d) On load change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps - 01 No
(e) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos
(f) Time switches 415 V three phase of 20 Amp rating with contactor fitted inside steel enclosure.
(g) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(h) Fine wiring with single core copper conductor cable for instruments / indicating lamps - 01 Job.
(j) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply, installation, test and commissioning (CPRI APPROVED) factory fabricated, out door type, LT pannel board made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection dust and vermin proof , double door with both side opening including noprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50 X 50 X 6mm mild steel angle iron frame and 750 mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and tesing after installation including complete all as specified and comprising of the following:- (Location - In proposed Maintenance Hall / Hanger )
INCOMING :
(a) Bus bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding in separate sheet steel enclosure.
(b) MCCB with thermal based release, 4 pole, 250 Amps, 50 Hz, 35 KA - 01 No ( I/C )
(c) Digital multi function panel mounted meters for energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS 13779:99/IEC 61036, CL 1.0, operating temperature -10 to +55 ˚C, relative humidity 95% non condensing, 96 X 96 X 86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mm X 4.8 mm, Protection index IP54 with all necessary CTs, PTs and instrument fuses and wiring.- 1 No
OUTGOING :
(a) MCCB with thermal based release, 3 pole, 125 Amps, 50 Hz, 35 KA - 03 No ( O/G ) (3 ph Power socket 63 Amps DB in hanger & DB power circuit in rooms & 3 phase 32 amp socket in rooms)
(b) MCCB with thermal based release 3 pole, 63 Amps, 50 Hz, 25 KA - 08 Nos (O/G) (i) 1 ph power socket DB in hanger & hanger lighting (ii) Split Acs (iii) Spare
(c) MCCB with thermal based release, 3 pole, 32 Amps, 50 Hz, 25 KA - 02 No ( O/G ) lighting DB & spare
(d) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos
(e) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(f) Fine wiring with single core copper conductor cable for instruments / indicating lamps - 01 Job.
(g) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply, installation, test and commissioning (CPRI APPROVED) factory fabricated, out door type, LT pannel board made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection dust and vermin proof, double door with both side opening including noprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded with 50 X 50 X 6mm mild steel angle iron frame and 750 mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and tesing after installation including complete all as specified and comprising of the following :– (location - CPA)
INCOMING :
(a) Bus bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed capacity 300 Amps with colour coding in separate sheet steel enclosure.
(b) MCCB with thermal based release 4 pole, 200 Amps, 50 Hz, 50 KA - 01 No
(c) Digital multi function panel mounted meters for energy metering, monitoring and management system suitable for LT 3 phase 4 wire applications, using micro-controllers and non volatile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS 13779:99/IEC 61036, CL 1.0, operating temperature -10 to +55 ˚C, relative humidity 95% non condensing, 96 X 96 X 86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 mm X 4.8 mm, Protection index IP54 with all necessary CTs, PTs and instrument fuses and wiring.- 1 No
OUTGOING :
(a) MCCB with thermal based release 3 pole, 63 Amps, 50 Hz, 25 KA - 03 No
(b) MCCB with thermal based release 3 pole, 32 Amps, 50 Hz, 25 KA - 03 No
(c) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos
(d) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(e) Fine wiring with single core copper conductor cable for instruments / indicating lamps - 01 Job.
(f) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply and install indoor automatic power factor correction panel (APFC) double door both front and back side factory made weather, dust & vermin proof of cylindrical type capacitor bank, fully compartmentalized construction heavy duty of 150 KVAR capacity with variable correction capacitors (6 X 5 KVAR + 2 X 10 KVAR + 4 X 15 KVAR + 2 X 20 KVAR ) and suitable for 415/ 440 Volts, 3 Phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 2.0 mm tick CRCA sheet and Min 1.6 mm thick for partitions with base channel, danger plate, earth bus bar chamber and cable ally at bottom rtc. comprising of compartment with hinged door, cable alley, bus bar chamber with bolted door etc duly powder coated comprising of the following.
(a) APFC Relay - 16 stage
(b) MCCB, Four Pole, 200 Amp with thermal magnatic release, 36 KA - 01 No (incoming)
(c) Digital multi function meter showing voltage current power, PF etc - 01 Nos.
(c) Phase indicating LED lamps (R-Y-B) - 01 set.
(d) 2 set of 5 KVAR LTXL ultra heavy duty capacitor with contactor and suitable MCB TP
(e) 2 set of 10 KVAR LTXL ultra heavy duty capacitor with contactor and suitable MCB TP
(f) 6 set of 15 KVAR LTXL ultra heavy duty capacitor with contactor and suitable MCB TP
(g) 5 set of 20 KVAR LTXL ultra heavy duty capacitor with contactor and suitable MCB TP
(h) Illuminated push on/ off for capacitor bank - 01 set
(j) Intrnal wiring of panel with standerd copper cable of suitable size.
Supply, fix, connect and test LED street light fitting 60W , pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management, including wiring from junction box / OH line to the fitting, complete all as specified and directed.(Make - Crompton Cat part No LST-60-CDI-M or equivalant of makes listed in Appendix 'C'
Supply and fix junction box of size 250 x 200 x 100mm with industrial connector including clamps made out of MS flat iron 30 x 5mm including connection from junction box to street light fitting with suitable size MCB and 3 core PVC insulated & PVC sheathed copper conductor cable 1.5 sqmm size complete all as specified and directed. Cat No GSJB -2520 of Sintex or equivalent of makes listed in Appendix 'C'
Supply and fix Alpha Rex3 digital time switches D-22 Astro, multifunctional digital time switches all as specified and directed by Engineer-in-Charge.
M&L for fabrication and installation of GI pipe bracket made of medium grade tubing of size 40mm dia duly bended by hot forging after filling of sand, length 1.20 mtr including two pairs of MS flat strip clamps 30 x 5mm with GI bolts, nuts and washers complete all as specified and directed.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/Sqcm, laid in trenches of size 100 mm dia suitable for cable protection complete all as specified and directed.
M&L for Pre-cast cement concrete kerb stone of size 450mm x 300mm x 150mm (H x L x Thickness) (factory made) in M-20 (Design mix) , straight or curved on plan not exceeding 6m mean radius and set in cement mortar (1:4) complete all as specified and as directed.
M&L for painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exceeding 10cm wide with 2mm thick road marking with using thermoplastic paint by using fully/semiautomatic application machine fitted with profile shoe heater driven by experianced operator on road surfaces including preparation of previously treated road surfaces, complete all as specified and as directed.
M & L for 150mm thick (compacted thickness) Wet Mix Macadam (WMM) laid in two layers 75mm each layer, laying spreading (with paver finisher only) and compacting base course of graded stone aggregates and granular material conforming to MORT&H specifications,(Table 400-II) in layers of equal compacted thickness each, consolidated, including pre-mixing the material with water at OMC in mechanical mixer, carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub base/ base course and compacting with power vibratory roller to achieve the desired density complete as per MORT&H specification clause -406 including material, labour, machinery, lighting, guarding and maintenance of diversion, complete all as specified and as directed.
M&L for 60mm thick machine pressed pre-cast cement concrete interlocking paver blocks with grey cement and pigment, rubber moulded any shape and size confirming to IS 15658-2006, M-35 grade as in floor/pavement laid over and including 25mm thick crushed stone sand complete all as specified and as directed.
M&L for forming 20mm thick expansion joints to 100mm thick concrete slab and filled with pre moulded compressible polythene closed cell medium density cross linked polymeric material back up rod of 25mm dia over filler board, priming top 12mm with approved primer and filling with polyurethene based sealent, applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after filling of sealent complete all as specified and as directed.
M&L for forming construction joint 35mm deepx 10mm wide ( using dimond cutter) in 100mm thick concrete slab and applying closed cell medium density cross linked polymeric material back up rod of 12mm dia over filler board, priming top 10mm with approved primer and filling with polyurethene based sealent, applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after filling of sealent complete all as specified and as directed.
M&L for forming dummy/contraction joint with initial saw cut 3mm blade (using dimond cutter)for depth 65 widening the first saw cut to 10mm wide and 22mm deep in PQC slab and applying closed cell medium density cross linked polymeric material back up rod of 12mm dia over filler board, priming top 10mm with approved primer and filling with polyurethene based sealent, applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after filling of sealent complete all as specified and as directed.
Supply, installation, test and commissioning (CPRI type tested) factory fabricated, Indoor type,, LT Panel made out of 2.00mm thick CRCA sheet with projected globe room for rain water protecton dust and vermin proof, double door with both side opening including noprene rubber gasket, suitablefor 440 volt 3 phase 4 wire system, including danger plate, earthing strip pt and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc and embeded with 50 x 50 x 6 mm mild steel angle iron frame and 750 mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable galnds PCC foundation in cement concrete 1:3:6 (20 mm graded store aggregate) and tesing after nstallation including complete all as specified and comprising of the fwg : (Location - Pump House)
INCOMING :
(a) Bus bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 630 Amps with colour coding in separate sheet steel enclosure.
(b) High breaking capacity MCCB 400 Amps, 50 Hz, 415 V rupturing capacity 50 KA 01 No (INcomer)
(c) Digital multi function panel mounted meters for energy metering, monitoring and management systme suitable for LT 3 Phase 4 wire applications, using micro-controllers and non voltile memory and providing anti tamper features and communication facility at high accuracy with accuracy for active energy as per IS 13779:99/IEC 61036, CL 1.0, operating temperature - to +550C, relative humidity 95% non condensing, 96 x 96 x 86 mm or nearer size, 3 line backlit display of 6 digit each to display voltage, current, active power, reactive power, apparent power, power factor frequency and other parameters, digit height 8 x 4.8 mm, Protection index IP54 with all necessary CTs, PTs and instrument fuses and wiring :-1 No
OUTGOING
(a) MCCB with thermal based release 4 pole, 200 Amps, 50 Hz, 35 KA - 02 Nos
(b) MCCB with thermal based release 4 pole, 63 Amps, 50 Hz, 35 KA - 02 Nos
(c) MCCB with thermal based release 4 pole, 32 Amps, 50 Hz, 35 KA - 03 Nos
(d) Star Delta Starter complete suitable 90 HP capacity - 02 Nos
(e) DOL Starter of 7.5 HP capacity - 02 Nos
(f) LED type/ Neon type indicating lamps panel mounting type RYB-3 Nos
(g) Internal wiring with single core conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/ MCB-1 Job.
(h) Fine wiring with single core copper conductor cable for instruments/ indicating lamps - 01 Job.
Suply, install, jointing, testing & commissioning of CIDF foot valve 150 mm dia complete with stainer for suction all as specified and as directed.
Suply, install, jointing, testing & commissioning of CIDF foot valve 80 mm dia complete with stainer for suction all as specified and as directed.
Suply & Fix CP Fire fighting RRL hose pipe of 63 mm dia 15 mtr long alongwith GM male and female couppling duly bound with GI wire conforming to IS 8423 with ISI marked & approved, all as specified and as directed.
Supply & fix fire hose cabinet of size 1000 x 1000 x 300 mm out door type with pedestal & grouted with suitable PCC foundation, fabricated from 16 gauge, MS sheet with double leafed glazed shutters (glazed with 4 mm thick sheet glass) the cabinet shall have powder quoted finish both internally & externally in signaled shade with : FIRE HOSE" written in bold letters on front & side faces suitable to house, two lengths canvas hoses 30 mtr long, 63 mm dia along with GM male & famale coupling duly bound with GI wire conforming to IS 8423 with ISI marked approved with and including nozzle, one branch pipe, one fireman axe & hose reel of suitable size etc coplete all as specified & directed.
Supply & install MS Pipe stand post of 80 mm dia 1.5m height with flange gasket and nut bolts all as specified and as directed.
Supply & install intel 4 way for fire brigade to the main pipe ring with butterfly valve of 150 mm ida and NRV of 150 mm dia size with instaneous manifold all as specified and as directed.
Supplying and installing 63 mm dia gun metal single outlet hydrant valve fitted with necessary accessories complete, ISI marked. all as specified and as directed.
Supply and install wall mounting, swinging hose reel drum as per IS 884 and fitted with 25 mm dia 30 mtr long high pressure polyproplene (Polyhose) pipe high pressure as per IS : 444 (Type III) Gun metal chrome plated nozzle and 25 mm dia gun metal gate valve on the inlet pipe with necessary MS Bracket for holding Hose reel drum fitted in position with wall fasteners, etc as approved complete all as specified & directed.
Supply & installation of ISI marked single headed 63 mm dia gun metal Hydrant Valve flanged including 63 mm female installation outlet confirmig to IS 5290 on the fire wet riser/ down corner including making 80 NB pipe connection with reser fixing with reser the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. Testing the hydrant and completing the work in all respect all as specified and directed.
Supply, Installation, Testing & Commissioning of Fire Pump Control Panel (MCC). The control part should have logic such that, in the event of any hose reel or landing valve is opened, then the pressure in the line drops and the pressure switches installed on the pump manifold give the indication for the jockey pumpto start, if more than one landing valves are opened then as sufficient pressure is not built up in the line by jockey pump, hence it will stop and main pump starts. Floor/Mounting/ wall Mounting all as specified and directed.
Supply only fire ladder aluminium with wheel mounted 25 feet high with above 8 feet extended type, all as specified and as directed.
Supply and installing pressure switch with 12/ 15 mm dia, isolation valve, GI nipple,elbow etc in an approved manner all as specified and as directed.
M& L for cutting of existing CI tubing of size 300mm bore for taking out branch connection of CI pipe 300mm dia including one number CI reducer tee of size 300mmx300mmx100mm all ends socketed type 01No., tail piece CI 300mm spigot and socketed 02No., run lead joints 300mm 4 joints and 100mm 01 joint including jointing material and necessary excavation and earth work in any type of soil complete all as specifed and as directed.
M & L for HDPE Pipes 125mm dia of pressure rating 6kgf/Sqcm laid in trenches as in protection to HT/LT cable of size 95Sqmm to 240Sqmm complete all as specified and directed.
M & L for HDPE Pipes 100mm dia of pressure rating 6kgf/Sqcm laid in trenches as in protection to HT/LT cable of size 10Sqmm to 70Sqmm complete all as specified and directed.
Supply & Fixing CI sluice valve of size 100mm dia bore, both ends flanged and drilled, bonnet wedge stuffing box, gland thrust plate, hand wheel made out of grey CI, confirming to IS 14846/2000 and its fittings suitable for hydraulic pressure 15Kg/Sqcm, PN 1.6,ISI Marked complete with all lead, lift and fixing including cost of nuts and bolts etc.all as specified and directed.
Horizon Construction
DAS Offshore Engg. Pvt. Ltd.
SUYOG CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .