Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹60.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Non responsive as per conditions laid down in the bid document | |
| 3 | Rejected-Technical RNB ROAD KOKRAJHAR ASSAM | KOKRAJHAR | ASSAM | 783331 | - | Rejected-Technical Non responsive as per conditions laid down in the bid document | |
| 4 | Rejected-Technical | - | Rejected-Technical Non responsive as per conditions laid down in the bid document | |
| 5 | Rejected-Technical H NO 69 SANTIPUR HILL SIDE GUWAHATI PIN 781009 | KAMRUP METRO | ASSAM | 781009 | - | Rejected-Technical Non responsive as per conditions laid down in the bid document |
Tender Value
₹76.8 L
EMD Value
₹1.5 L
Closing Date
15 Jun 2023, 2:00 pmClosed
REGISTRAR, COTTON UNIVERSITY
Panbazar, Ghy-01
Electrical Works
2023_CU_31121_1
CU/EC/2020/085/6412 Dated 06.06.2023
Open Tender
Electrical Works
Item Rate
150 days
Panbazar
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹1.5 L
Yes
O/o of the Registrar, Cotton University
17 Jul 2023
8 Jun 2023
15 Jun 2023
8 Jun 2023
15 Jun 2023
8 Jun 2023
12 Jun 2023
Amount
Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 650/1100 V grade conforming to IS 7098 (Part - I) / 1988 with amendment up to date etc as required.
3.5 X 240.0 sq.mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 185 sq. mm and upto 400 sq. mm
SITC of floor mounted indoor type, free standing, dust and vermin proof, 3-Ph, 4Wire, 415V, 50Hz, AC supply, LT panel board fabricated from 1.6mm CRC Sheet, finished with powder coating after chemical treatment & providing TPN 800A copper bus bar & wiring, consisting of the following feeders:- As incomer:-
800A, 4P, 50KA, EDO with microprocessor based ACB - 1 nos
Microswitch for ACB - 1 nos
ON, OFF, Trip indicator lamp for ACB - 1 nos
Digital Voltmeter (0-500V) - 1 nos
Digital Ammeter (0-800A) - 1 nos
LED indicator lamp R,Y,B - 3 nos
CT 800/5A, Cl-, Tape wounded - 3 nos
6A, SP, MCB - 4 nos
As outgoing:-
Space provision for 630A, TP, MCCB with spreader link - 1 nos
Space provision for 400A, TP, MCCB with spreader link - 2 nos
Space provision for 250A, TP, MCCB with spreader link - 3 nos
Space provision for 40A, 4P, MCB with spreader link- 6 nos
Earthling bus 50x6mm- 1 nos
(Incoming switchgear i.e; 800A ACB is included, outgoing switchgear to be measured and paid separately)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
630 A, 50 KA,TPMCCB
400 A, 35 KA,TPMCCB
250 A, 35 KA,TPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral
Supplying installation, testing and commissioning of Hospital bed elevator for 3 stop (1360 Kg 20 persons) having contract speed of 1.25 Metre/Sec (approx.) mps serving different floor in the existing lift shaft as per detailed specification enclosed and as under
Location of the lift-
1.Type & Capacity-Passenger- 20 persons, 1360 Kg
2.Speed- 1.25 Metre./Sec (approx.)
3.Type of Drive- Variable Voltage, Variable Frequency Drive with Microprocessor based Simplex Full Collective Control.
4. Location of Machine Room- NA
5. Available Travel- 28 metres. ( Maximum)
6. Serving- Ground Floor to 6th Floor, 7 Stops 7 Levels 7 Openings
7. Well Size- 2550 mm WideX 2350 mm Deep over the finished surface
8. Power supply- 415 Volts 3 phase, 50 cycles alternating current
9. Auxiliary Required- Single-phase 220 V 50 Cycles alternating current.
10. Cab size (Clear Inside) approx.---1700 mm wideX 1800 mm Deep.
11. Pit Depth--1600 mm
12. Head Room-5000 mm.
13. Car Enclosure- Stainless Steel Car- Moonrock Finish.
14. Flooring- S.S. Cheq. Plate Flooring
15. Electric Light- Jlpl135
16. Fan- Cross Flow - Fan
17. No of Entrances- One Location - Front
18. Car Entrance- Centre Opening Sliding Door
19. Landing Entrance- Landing Operating Panel - JLLP01
20. Clear Opening- 1000 mm Wide X 2000 mm High.
21. Indicators-Car & Landings-Direction & Position Indicator.
Other Features --Emergency Alarm & Light.
Call Registration LEDS .
OSG Electronic Switch.
Fireman Drive
Intercom.
Full Length Infra Red door Safety.
Auto Rescue Device
Supply and installation of 20 KVA online UPS for lift application as per specification. The followng specifications are to be maintained: 1.Three phase in and three phase out 20KVA online inbuilt isolation transformer. (Make: Fuji electric model-Falcon 8500) 2.Batteries back-up for 10 mins using 32 nos. 12V 26AH SMF exide batteies. 3. Rack connectors.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .