| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.8 L+₹2.8 L (8.73%)Rejected-AOC | L2 | Rejected-AOC Being Not L1 | |
| 3 | L3₹36.2 L+₹4.2 L (13.0%)Rejected-AOC | L3 | Rejected-AOC Being Not L1 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
13 Feb 2020, 6:00 pmClosed
Col PS Chand CWE Port Blair
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat Post, Port Blair 744103
REPAIR/ MAINT OF AIR CONDITIONING PLANTS, CENTRAL AC PLANTS AND PACKAGE TYPE AC OF AGE E/M NO 1 UNDER GE MINNIEBAY, PORT BLAIR
2020_MES_316166_1
80872-Rep-Maint-AC-minniebay
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Port Blair
All as per tender documetns
8 documents required · 8 mandatory
₹500
Yes
GE Minniebay
₹76,000
Yes
18 Mar 2020
18 Jan 2020
19 Feb 2020
18 Jan 2020
13 Feb 2020
1 Feb 2020
Amount
Overhauling of compressor of model SMC 4-100 and make 'ACCEL' including taking down unserviceable parts and refixing new parts where ever necessary complete all as directed by Engineer-in-Charge after the pumping down the complete system and collecting the refrigerant into container, compressor oil into clean container, disconnecting the compressor from suction & discharge side and including leak testing of compressor after reassembling the parts, recharging/ filling retrieved oil & gas, replacement of belt if required, refixing in its original position, connecting, testing and commissioning upto satisfactory cooling performance, complete all as specified and as directed. Notes : (i) Spare parts , refrigerant (gas) and compressor oil for top up if required shall be measured and paid for separately as supply only under respective items of this schedule. (ii) Metal filling, grinding, polishing spring, washer, quarter pin and consumable items such as grease, cotton waste, etc., are deemed to be included in the quoted rate. (iii) Belt shall be measured and paid for separately as supply only under respective item of this schedule.
Supply and fix in repair/replacement of panel air filters, dry type, washable, rated air flow capacity 1600CFM efficiency 99.9%, down to particle 20 micron of sizes 600x500x43mm or nearest in AHU of Central AC plant all as specified and as directed. Note : Quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.
Supply and fix in repair/replacement of Solenoid pilot control valve, Type 10 with coil assembly as per OEM suitable for 36TR AC plant. Note : Quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.
All as per Item No.3 above but HP/LP cut off switch, MP-15 suitable for working on R-22 gas compete with flare nut. [Make : Danfoss]
All as per Item No.3 above but Oil pressure cut off switch, MP-55, suitable for working on R-22 gas with flare nut. [Make : Danfoss]
All as per Item No.3 above but 3 pole power Contactor 25Amps rated [Model : MNX 25] with coil voltage 230Volts, AC. [Make : L&T or equivalent]
All as per Item No.3 above but Contactor 18Amps rated [Model : MNX 18] with coil voltage 230Volts, AC. [Make : L&T or equivalent]
All as per Item No.3 above but Bi-metal overload relay, direct mounting type suitable for MNX 18 contactor of range 6-12Amps.
All as per Item No.3 above but Bi-metal overload relay, direct mounting type suitable for MNX 25 contactor of range 12.5Amps to 25 Amps.
All as per Item No.3 above but Thermal Timer 250Volts AC, 5-18seconds. [Model : GT-200 of Make : L&T or equivalent model] .
All as per Item No.3 above but Expansion valve assembly complete.
All as per Item No.3 above but Electronic Star delta timer Type ST 100 [Make : L&T or equivalent]
All as per Item No.3 above but Nozzle for Cooling tower
All as per Item No.3 above but 3 pole power Contactor 45Amps rated [Model : MNX-45 and Make : L&T or equivalent]
All as per Item No.3 above but Thermal Overload Relay [Model : MNZ of Make : L&T or equivalent]
All as per Item No.3 above but Eight pin relay
All as per Item No.3 above but Thermostat unit [Make : Danfoss]
All as per Item No.3 above but water cutout switch
All as per Item No.3 above but oil pressure gauge of range 0 to 150
Material and Labour for repair/ servicing of monoblock pump 40HP capacity by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the pump motor, cleaning the pump, greasing to bearing/ bushes, replacing the gland rope, gland nut, bolts, opening motor, varnishing to stator with class I varnish, heating/ baking the same, cleaning the rotor and re-assembling the same, brought back to site, fixing it at its original location with proper alignment including connecting, testing and commissioning complete all as specified and directed.
All as per Item No.21 above but monoblock pump of 10 HP capacity
All as per Item No.21 above but monoblock pump of 7.5 HP capacity
Material and Labour for repair/ servicing of AC electrical motor of 40 HP capacity, 3 phase 440Volts by disconnecting/ dismantling (electrically & mechanically) and transport to workshop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding the motor stator with appropriate gauge and turns of synthetically enamelled copper wire using proper insulating material (F-class) varnishing with class I varnish, heating/baking, cleaning and greasing to bearings, cleaning the rotor, reassembling the motor completely and brought at site, fixing it at its original location with proper alignment including connecting, testing and commissioning complete all as specified and directed.
All as per Item No.24 above but monoblock pump of 10 HP capacity
All as per Item No.24 above but monoblock pump of 7.5 HP capacity
Supply only 'O' Ring Set for compressor of Model No : SMC 4-100 Make : ACCEL.
All as per Item No.27 above but 'Dowty Ring Set'
All as per Item No.27 above but 'Sealing Ring Set'
All as per Item No.27 above but 'Oil Filter'
All as per Item No.27 above but 'Main Bearing (U/s 0.25/0.50mm)'
All as per Item No.27 above but 'Bearing Bush'
All as per Item No.27 above but 'Piston Ring Set'
All as per Item No.27 above but 'Piston Pin'
All as per Item No.27 above but 'Piston'
All as per Item No.27 above but 'Seeger Ring Standard Size'
All as per Item No.27 above but 'Oil Charging Valve'
All as per Item No.27 above but 'Cylinder Liner (Standard Size)'
All as per Item No.27 above but 'Gudgen Pin'
All as per Item No.27 above but 'Oil Pump Assembly (OEM)'
All as per Item No.27 above but 'Unloading Cylinder'
All as per Item No.27 above but 'Connecting Rod'
All as per Item No.27 above but 'Safety Valve Assembly'
All as per Item No.27 above but 'Oil seal assembly'
All as per Item No.27 above but 'Suction Lead'
All as per Item No.27 above but 'Discharge Lead'
All as per Item No.27 above but 'Liner Complete Set'
Supply only 'V' belt of size C-96
Supply only 'V' belt of size C-98
Supply only 'V' belt of size SPA 2000
Supply and fix in repair/replacement new shaft seal assembly for compressor of Model : SMC 4-100 and of Make : 'ACCEL' with imported carbon ring, etc., including taking down carefully defective/ unserviceable shaft seal assembly complete all as specified and as directed.
Supply and fix in repair/replacement and testing CI non return valve of size 80mm, both ends flanged including provision of joining material such as insertion sheet 3mm thick, nut, bolts & washer all as required at site including taking down carefully defective/ unserviceable non return valve all as specified and as directed. Make : Kirloskar/ Venus/ Leader/ Audco
Supply and fix in repair/replacement and testing CI Butter fly valve of size 100mm dia, both ends flanged including provision of joining material such as insertion sheet 3mm thick, nut, bolts & washer all as required at site including taking down carefully defective/ unserviceable Butterfly valve all as specified and as directed. Make : Kirloskar/ Venus/ Leader/ Audco
All as per Item No 53 above but of size 80 mm dia
All as per Item No 53 above but of size 65 mm dia
All as per Item No 53 above but of size 50 mm dia
Supply and fix in repair/replacement and testing suction & discharge valve for compressor of model 'SMC 4-100' and of make 'ACCEL' including teflon washer sheet, suction & discharge valve ring, spring, 'O' rings, gaskets, etc., complete and testing complete for proper holding of valve, leak testing etc all as specified and as directed.
Material and Labour for descaling the condenser unit (three numbers in each unit) of AC plant with capacity 72TR (2x36TR Running + 1x36TR Standby) cooling unit by means of circulating the descaling chemical (scale gun) (HCL Acid) through condenser by pressure feeding method after disconnecting condenser water lines, opening the end covers, scraping/ cleaning/ brushing the condenser water tubings, removing the scales, normalising the copper surface by circulation of normalising agent and reassemble the dismantled part, end cover with new 3mm thick rubber gasket set and connecting with the system, testing and commissioning complete all as specified and as directed.
Material and Labour for cleaning/ servicing the cooling coil of AHU AC plant by pressure air method with air blower and cleaning the cooling coil with cleaning solution, cleaning the AHU base tray completely and applying one coat of synthetic enamelled paint inside the base tray including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of 'V' belt (if required), etc., complete all as specified and as directed. Note : 'V' belt shall be measured and paid separately as "supply only" under respective item of this Schedule .
Material and Labour for leak testing of AHU unit cooling coil of AC plant after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point by means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning upto satisfactory cooling performance of the plant complete all as specified and as directed.
Material and Labour for cleaning/ servicing of cooling tower , natural draught type of central AC plant including cleaning of wooden louvers by scraping inside and outside, cleaning of water tank, cleaning of nozzles (Brass/PVC), arranging all wooden louvers in correct manners, and applying one coat of bituminous paint inside and outside of water tank complete all as specified and as directed.
Material and Labour for preparation of old painted surfaces of central AC plant 72TR (2x 36TR + 1 x 36 Stand by) capacity in DHANVANTARI Hospital and applying two coats of synthetic enamelled paint to external surfaces of compressor-03Nos, compressor motor-03Nos, foundation of compressor & motor units-03Nos, suction & discharge refrigerant pipe line, condenser water pump with motor & foundation-02Nos, water pipe line, AHU unit-01No, AHU Motor-01No, Condenser-03Nos all as specified and as directed. Note : The quoted rate shall be deemed to include the cost of writing SM/ MES Number.
Material and Labour for servicing of water cooled scroll chiller type central air conditioning plant of 3x50 TR capacity (HQ 34 WEU)comprising of hermetically sealed scroll compressor using R-407C refrigerant driven with 2 pole squirrel cage induction motor refrigerant cooled, 3phase, 415V, water cooled condenser and DX cooler with thermostatic expansion valve with in-built control panel having microprocessor control for operation of compressor, condenser, cooler having features of auto operation, run time equalisation, memory back up, auto restart after power failure, built in time delay, fault diagnostics, etc. including taking down unserviceable parts and refixing new parts where ever necessary complete all as directed by Engineer-in-Charge after the pumping down the complete system and collecting the refrigerant into container including leak testing of compressor after reassembling the parts, recharging/ filling retrieved gas, connecting, testing and commissioning upto satisfactory cooling performance, complete all as specified and as directed. Notes : (i) Compressor, Spare parts and refrigerant (gas) for top up if required shall be measured and paid for separately as supply only under respective items of this schedule. (ii) Metal filling, grinding, polishing spring, washer, quarter pin and consumable items such as grease, cotton waste etc are deemed to be included in the quoted rate. (iii) Old unserviceable Compressor & spare parts retrieved from the plant shall be taken as schedule of credit by the contractor.
Material and Labour for cleaning/ servicing the cooling coil of AHU 15600 cfm of AC plant (HQ 34 WEU) by pressure air method with air blower and cleaning the cooling coil with cleaning solution, cleaning the AHU base tray completely and applying one coat of synthetic enamelled paint inside the base tray including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of 'V' belt (if required), limit switch, volume control dampers etc complete all as specified and as directed. Note : 'V' belt shall be measured and paid separately as "supply only" under respective item of this Schedule .
Material and Labour for leak testing of AHU 15600 cfm unit cooling coil of AC plant(HQ 34 WEU) after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point by means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning upto satisfactory cooling performance of the plant complete all as specified and as directed.
Material and Labour for cleaning/ servicing of cross flow induced draught bottle type 100 TR FRP cooling tower of central AC plant (3x50 TR capacity) including cleaning of rotating sprinkler assembly, water collecting basin, complete outer structure of cooling tower by scraping inside and outside and including painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed
Material and Labour for cleaning of make up water tank PVC of capacity 5000 litres by emptying the tanks, removing scale, dirt and all other foreign materials deposited on walls and bottom of the tanks by scraping and brushing with wire brush and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water, checking and removing airlock if any on next day after cleaning of the tank and writing the capacity of tank and date of cleaning all as directed.
Supply and fix MCCB 4 Pole 400 A, 50 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: CM98404OORO or equivalent
Supply and fix MCCB 4 Pole 125 A, 25 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T , Cat Part No: CM90634OOMO or equivalent
Supply and fix MCCB 4 Pole 100 A, 18 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T , Cat Part No: CM90518OOKO or equivalent
Supply and fix MCCB 3 Pole 63 A, 10 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T , Cat Part No: CM97757OOOO or equivalent
Supply and fix MCB 3 Pole 06-32 A, 10 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: BB30060B to BB30320B or equivalent
Supply and fix MCB Single pole and neutral (SPN) 06-32 A, 10 KA breaking capacity including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: BB20060B to BB20320B or equivalent
Supply and fix 3 pole power contactor of capacity 32 Amps including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: CS94111, Model: MNX-32 or equivalent
Supply and fix 3 pole power contactor of capacity 25 Amps including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: CS94111, Model: MNX-25 or equivalent
Supply and fix Star-Delta starter air break suitable for chilled water pump of capacity 7.5 HP including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: SS96255 or equivalent
Supply and fix DOL starter suitable for Cooling tower motor of capacity 5 HP including taking out old unserviceable one all as specified and as directed. Make: L & T, Cat Part No: SS96210 or equivalent
Supply and lay LT UG cable XLPE insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of size 3.5 core 95 sqmm complete all as specified and as directed including taking out old unserviceable one and taken as schedule of credit.
All as per Item No 78 above but of size 3.5 core 35 sqmm
All as per Item No78 above but of size 4 core 16 sqmm
Supply only Compressor 12.5 TR Capacity of Make: Danfoss, Model: S2185S4Re
Supply only Water flow switch of Pressure capacity 10 bar. Model: HFS-25 (As per sample)
Supply only Fuse cut out of 125 Amps capacity for compressor as per sample. Make: L & T, Cat Part No: SF94030 or equivalent
Supply only Thermostat for Chiller In and out temperature control as per sample.
Supply only V-belt of Model B-73 for AHU as per sample.
Supply only coil sensor for Auto start of 12.5 TR Compressor as per sample.
Supply only Cooling tower fan of 100 TR Capacity AC plant as per sample.
Supply and Fix water pressure gauge 0 to 7 Kgf/cm2 or as per sample. Make: Fiebig
Supply and fix in repair/ replacement of Condenser fan motor, single shaft, single speed, 1400RPM, 230Volts AC, suitable for 4.5/5TR capacity Cold Storage Plant as per OEM including taking out burnt/ unserviceable condenser fan motor all as specified and as directed.
Supply and fix in repair/ replacement of Single phase preventor suitable for 4.5/5TR capacity Cold Storage Plant all as specified and as directed. [Model : VSP-D1/VSP-D2 of Make : Milnilec or equivalent model] Note : The quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.
All as per Item 90 above but Over load relay direct mounting type of range 2-3.2Amps as per OEM.
All as per Item 90 above but Defrost delay timer with switch [Make : L&T or equivalent model]
All as per Item 90 above but Thermostat unit for cold storage suitable on working 12˚C to 2˚C for defrost and (minus) (-) 5˚C at 'ON' condition as per OEM.
All as per Item 90 above but Condenser assembly with copper tubing suitable for 4.5/5 TR compressor of existing size (Single layer/ double layer) and base mounting [Make : Bluestar or equivalent model]
All as per Item 90 above but Cooling coil assembly for indoor unit with copper tubing suitable for 4.5/5 TR compressor of existing size and base mounting. [Make Bluestar or equivalent model]
All as per Item 90 above but Tray heater suitable for existing cold room [Make : Bluestar or equivalent model]
All as per Item 90 above but Analog switch timer [Make : L&T or equivalent]
All as per Item 90 above but Phase failure relay [Model : VSP D1; Make L&T or equivalent]
All as per Item 90 above but Thermostat unit for cold storage suitable on working 10˚C to 20˚C for defrost and (minus) (-) 5˚C at 'ON' condition as per OEM.
All as per Item 90 above but Subzero display [Model : SZ-7510-P; Make : Scientific]
All as per Item 90 above but HP LP cutout [Make : Danfoss]
All as per Item 90 above but Thermal expansion valve [Make : Danfoss]
All as per Item 90 above but Eliminator liquid line filter drier model DCL 162 [Make : Danfoss]
All as per Item 90 above but MCB TPN 32Amps. [Make : L&T, Cat Part No: BB40320B or equivalent]
All as per Item 90 above but MCB, SP 06 to 32 Amps. Make : L&T, Cat Part No: BB10060C to BB10320C or equivalent
All as per Item 90 above but Ammeter Analog as per existing size and range 0 to 100Amps
All as per Item 90 above but Voltmeter Analog as per existing size and range 0 to 500Volts
All as per Item 90 above but RYB indicator Lamp, LED type as per existing size
All as per Item 90 above but Mushroom button as per existing size & capacity
All as per Item 90 above but Phase failure overload protection of range 20Amps [Model : MPR- 1; Make : Minilec]
All as per Item 90 above but Evaporator fan of size 34x34x19, [Model No : YMF4E400SC; Make : Axiel]
All as per Item 90 above but Evaporator fan of size 50x50x22, Type REC4E-450A [Model No : YDWF68M4-360N-300 Section]
Supply and fix in repair/ replacement of Thermostat No 2059 with knob for window type AC all as specified and as directed. [Note : The quoted rate shall be deemed to include for taking out old unserviceable spares/ item and provision of new spares/ item.]
All as per Item 113 above but OLP-1622 relay for window type AC.
All as per Item 113 above but Potential box type relay/PTC relay of suitable model for window/split type AC.
All as per Item 113 above but Running capacitor 36 to 50 MFD, for Window/Split AC 1.5 TR
All as per Item 113 above but Running capacitor 36+6 MFD for Window/Split AC 2 TR
All as per Item 113 above but Running capacitor 50+6 MFD for Window/Split AC 2 TR
All as per Item 113 above but Running capacitor 45+6 MFD for Window/Split AC 2 TR
All as per Item 113 above but Running capacitor 50/60 MFD for Window/Split AC 2 TR
All as per Item 113 above but Running capacitor 6 to 10 MFD for Window/Split AC 2 TR
All as per Item 113 above but Running capacitor 2.5 to 4 MFD for Window/Split AC 2 TR
All as per Item 113 above but Metal top for sheet metal enclosure
All as per Item 113 above but Condenser assembly with copper tubing suitable for 1.5/2 TR compressor of existing size and base mounting. [Make : Blue Star or equivalent model]
All as per Item 113 above but Stand for Condenser motor in outdoor unit for 1.5/2 TR AC
All as per Item 113 above but PC board complete suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 113 above but Plasma filter suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 113 above but Blower motor, 230Volts, AC of indoor unit of split type AC of 1.5/2 TR Capacity.
All as per Item 113 above but Remote control complete suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 113 above but Fan/ blower motor, double shaft of window type AC of 1.5/2.0 TR capacity, single/ double speed, single phase, 230Volts, AC of 1/4 to 1/5 HP, complete and making suitable fixing arrangement in existing place including taking out burnt/ unserviceable fan/ blower motor of any type complete.
All as per Item 113 above but single shaft outdoor unit blower fan motor of split type AC of 1.5/2.0 TR capacity, single/ double speed, single phase, 230Volts, AC of 1/5 to 1/6 HP, complete and making suitable fixing arrangement in existing place including taking out burnt/ unserviceable fan/ blower motor of any type complete.
All as per Item 113 above but Fan blade (as per sample) for window type AC/Split AC of any capacity.
Material and Labour for MS sheet plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed.
Supply and fix exhaust fans totally enclosed, highly efficient AC Single Phase 230 V capacitor run heavy duty motor Single piece metallic blade of size 600 mm sweep (Heavy duty), including louvers/shutter and connecting up 3 core flexible cord of size 1.5sqmm from ceiling rose to exhaust fan all as specified and directed. Make : Usha, Bajaj & CG
Supply and fix in repair/ replacement of sheet metal enclosure with socket plug top & MCB single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20Amps all as specified and as directed.
Supply and fix in repair/replacement of FRLS cable 1100Volts grade 3 core, 2.5sqmm, multirstranded Copper conductor, PVC insulated from main supply point to outdoor unit point all as specified and as directed.
Material and Labour in repair/replacement of Copper tubing of size 5/8" flare size conforming to relevant IS all as specified and as directed.
All as per Item 137 above but 1/2" flare size.
All as per Item 137 above but 3/8" flare size.
Material and Labour for insulation of copper tubing for split unit of any capacity & any size from indoor to out door unit complete all as specified and as directed.
Supply and fix in repair, evaporator coil indoor unit tray heater 'U' type, 2105mm long constant wattage with 1 metre 3 core, multi-stranded copper conductor, 4sqmm, FRLS PVC sheathed cable and cold shrink sleeve all as specified and as directed.
Material and Labour for servicing of split type Air Conditioner 1.5/2.0TR capacity of any make including taking out the machine from its original location, removing the dust from body with blower, cleaning/ washing the condenser & cooling coil by using water and caustic soda, cleaning of entire elements of AC, oiling/ greasing to fan motor, checking all the connections and functioning of metal clad socket/ DP switch function of relay capacitors, overload protector, thermostat fan motor blade, fan/blower drum, etc., checking serviceability, changing the air filter woolen felt for air tighting, , refixing the machine at its original location, necessary testing and commissioning complete all as specified and as directed.
Supply & install in replacement of Indoor Unit only for Split AC of capacity 1.5/2.0 Ton including necessary accessories and connections complete all as specified and as directed.
Taking down carefully the Split AC from original location, shifting to other location and install the AC with copper tubing, filling of gas required, making hole in wall for copper tubing with all necessary connections and making good the disturbed surfaces of wall all as specified and as directed. [Note : Gas & Copper tubing shall be measured and paid separately under respective item of this Schedule as "Supply only".]
Material and Labour for servicing of indoor & outdoor unit of split type AC 3.5/4.5 TR capacity complete with soda wash to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to condenser motor, cooling coil, blower motor, including taking out and refixing the machine at its original location complete all as specified and as directed.
Supply and fix in repair, charged new sealed unit compressor for Window/Split type AC of capacity 1.5 TR of approved make, 230Volts, AC including taking out old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut & bolts, disconnecting from suction & discharge side mechanically and electrically including testing and charging the system with gas etc complete all as specified and as directed. Note : Gas shall be measured and paid separately under respective item of this Schedule as "Supply only". [Make : Hitachi/ Danfoss/ Kiloskar or equivalent as approved by OEM & GE]
All as per Item 146 above, but Compressor for Window/split type AC of capacity 2 TR
All as per Item 146 above, but Compressor for Window/split type AC of capacity 3.5 TR
All as per Item 146 above, but Compressor for Window/split type AC of capacity 4.5 TR
Material and Labour for leak testing one in number walk-in-freezer/walk-in-cooler comprising of condenser units and evaporator units with pressure testing the complete plant by dry nitrogen gas by separating high side and low side, brazing and low side, rectifying the leakage by gas welding, brazing, pressure testing, vaccumising gas, gas charging the system with existing Refrigerant gas, testing and commissioning all as specified and as directed.
Supply, install, test and commissioning in repair/ replacement hermitically sealed unit compressor 4.5/5 TR capacity as approved by OEM & GE suitable for working on R-22 gas including charging the system with gas, taking out old unserviceable hermitically sealed unit compressor 4.5/5 TR capacity, 3 phase, 440Volts, AC from outdoor unit of cold storage by means of disconnecting the suction and discharge refrigerant pipe line, electrical connection, etc., complete all as specified and as directed. [Make : Kirloskar/ Danfoss/ Copeland/ Hitachi]
All as per Item 151 above, but suitable for working on R-134A gas
All as per Item 151 above, but compressor of 4.5TR capacity of make 'Danfoss', suitable for working on R-404A gas.
All as per Item 151 above, but compressor of 5TR capacity of make 'Danfoss', suitable for working on R-404A gas.
Supply and fix in repair drain outlet PVC pipe 15mm dia connected from rear side of AC upto drain with necessary clamps and fixtures, fixed on wall and floor complete all as specified and as directed.
Supply only Compressor oil N-68. [Make : SERVO, Sheetal or equivalent as approved by GE]
Supply only Refrigerant gas R-22 in manufacturer's sealed cylinder.
Supply only Refrigerant gas R-404 A in manufacturer's sealed cylinder.
Supply only Refrigerant gas R-134A in manufacturer's sealed cylinder.
Supply only Refrigerant gas R-407/410 in manufacturer's sealed cylinder.
Note: Item Nos 157 to 160 : Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas.
Material and Labour for Servicing to dehumidifiers of Model FFB-170, FFB-300 & FFB-600 by dismantling and checking the following :- (a) Motor and starters/contactors for any loose connection/ unserviceability (b) Check bed speed and bed drive (c) Cleaning of air filters (d) Lubricating the bearings of motors/fan etc,. (e) Adjustment of sprocket wheel and chain (f) Checking of reduction gear unit, flexible connection of process and reactivation fans (g) Checking of air pressure balancing and air flow of the system. [Note : Spares required for replacement shall be measured and paid separately under relevant items of Schedule 'A' as "supply only".]
Supply only Bed drive reduction unit suitable for dehumidifier of any model. (Make : Bry air)
Supply only React fan motor suitable for dehumidifier of any model (Make : Bry air)
Supply only Heater suitable for dehumidfiier of any model (Make : Bry air)
Supply only Safety thermostat suitable for dehumidifier of any model. (Make : Bry air)
Supply only Process air filter suitable for dehumidifier of model FFB-170. (Make : Bry air)
Supply only Process air filter suitable for dehumidifier of model FFB-300. (Make : Bry air)
Supply only Process air filter suitable for dehumidifier of model FFB-600. (Make : Bry air)
Supply only React air filter suitable for dehumidifier of any model. (Make : Bry air)
Supply only Bed failure delay timer suitable for dehumidifier of any model. (Make : Bry air)
Supply only Bed failure limit switch suitable for dehumidifier of any model. (Make : Bry air)
Supply only React pressure switch suitable for dehumidifier of any model. (Make : Bry air)
Supply only Dessict motor suitable for dehumidifier of any model FFB-170.(Make: Bry air)
Supply only Dessict motor suitable for dehumidifier of any model FFB-300.(Make: Bry air)
Supply only Seal group suitable for dehumidifier of any model FFB-170 (Make : Bry air)
Supply only Seal group suitable for dehumidifier of any model FFB-300 (Make : Bry air)
Supply only Seal group suitable for dehumidifier of any model FFB-600 (Make : Bry air)
M/s Electrotech
EVEREST COOLING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .