| 1 | L1₹26,986Qualified Make: microtek
Model: Microtek NM72MX2KK11-IB 102 SHUKLA APARTMENT OPPSITE STATE BANK OF INDIA KAMPTHI LINE RAJNANDGAON RAJNANDGAON CHHATTISGARH 491441 | RAJNANDGAON | CHHATTISGARH | 491441 | Make: microtek
Model: Microtek NM72MX2KK11-IB | L1 | Qualified | |
| 2 | L2₹27,000+₹14 (0.05%)Qualified Make: NUMERIC
Model: Numeric - Legrand CHANDIGARH CHANDIGARH 160030 | CHANDIGARH | CHANDIGARH | 160030 | Make: NUMERIC
Model: Numeric - Legrand | L2 | Qualified | |
| 3 | L3₹27,800+₹814 (3.02%)Qualified Make: JYOTIPOWER
Model: JYOTIPOWER AJP3KVA120V 26 CH INDER SINGH MKT MAIN ROAD KHICHRIPUR DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | Make: JYOTIPOWER
Model: JYOTIPOWER AJP3KVA120V | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
2 Jul 2018, 11:00 amClosed
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 6048 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without With
Without
Without trollery but with rack 1/4 Warranty for battery 2 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. REGISTRATION ICRS20 15-07941R-41016861 - Type Test Certificate date 15/01/2015 - Name of Lab BIS - Address of Lab MANAK BHAVAN
9
BAHADUS SHAH ZAFAR MARG
NEW DELHI 110002 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Puran Chand 143001
12 Albert Road Mohindra House Amritsar 1 15 EMD Required No 3/4 ePBG Required No
255539
GEM/2018/B/36321
Online UPS
15 days
Punjab; Amritsar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 6048 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack 1/4 Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. REGISTRATION ICRS20 15-07941R-41016861 - Type Test Certificate date 15/01/2015 - Name of Lab BIS - Address of Lab MANAK BHAVAN | - | - | - |
| 9 | - | - | - |
| BAHADUS SHAH ZAFAR MARG | - | - | - |
| NEW DELHI 110002 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Puran Chand 143001 | - | - | - |
| 12 Albert Road Mohindra House Amritsar 1 15 EMD Required No 3/4 ePBG Required No | - | - | - |
Exempted
2 Jul 2018
26 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_255539.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .