Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | ₹19.2 L Quoted ₹20.2 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹19.2 L+₹1.5 L (7.22%)Accepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹19.2 L+₹1.5 L (7.22%) Quoted ₹21.7 L | L2 | Accepted-AOC WRONG FINANCIAL EVALUATION |
| 3 | L3₹22.2 L+₹2.0 L (9.85%)Rejected-Finance | ₹22.2 L+₹2.0 L (9.85%) | L3 | Rejected-Finance HIGHER |
| 4 | L4₹24.4 L+₹4.2 L (20.7%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹24.4 L+₹4.2 L (20.7%) | L4 | Rejected-Finance HIGHER |
| 5 | L5₹25.5 L+₹5.3 L (26.0%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹25.5 L+₹5.3 L (26.0%) | L5 | Rejected-Finance HIGHER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE Amritsar
GE Amritsar pin 143001
REPAIR/MAINTENANCE OF INTERNAL WIRING DB FITTING FIXTURES AT OTM ACCN INCLUDING DAY TO DAY MAINTENANCE IN THE AREA OF AGE BR-I UNDER GE AMRITSAR CANTT
2023_MES_602844_1
GE/ASR-26/2023-24
Open Tender
Civil Works
Works
180 days
GE Amritsar
Class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
28 Oct 2024
12 Jun 2023
11 Jul 2023
12 Jun 2023
10 Jul 2023
27 Jun 2023
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, brackets, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairss and white / colour wash etc.; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC conduit ISI marked concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge. One light/one fan/one bell point controlled by one, one way switch.
Supply and Fixing point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC conduit ISI marked concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge. One light point controlled by two Nos of two way switch.
Supply and Fixing point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge. One socket outlet 5 pin 5 Amp controlled by one, one way switch on same board.
Supply and Fixing point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge. One socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board.
All as per item here in before but wiring with using cable 2.50 sqmm size copper wire (FR) and earth wire of PVC insulated (Green colour) 2.50 Sqmm size copper wire for one 6 pin socket outlet, 16 Amperes on independent board.
Supply and Fixing Point wiring complete with 1.5 Sq mm (nominal area)FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 25 mm dia and 1.5 mm wall thickness and conduit fittings including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc ; Complete all as specified and directed by Engineer-in-charge.for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
Supply and Fixing Point wiring complete with 1.5 Sq mm (nominal area)FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 25 mm dia and 1.5 mm wall thickness and conduit fittings including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc ; Complete all as specified and directed by Engineer-in-charge.for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.) One light point controlled by two Nos of two way switch.
Supply and Fixing Point wiring complete with 1.5 Sq mm (nominal area)FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 25 mm dia and 1.5 mm wall thickness and conduit fittings including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc ; Complete all as specified and directed by Engineer-in-charge.for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.) One socket outet point 5 amps on the same board.
Supply and Fixing Point wiring complete with 1.5 Sq mm (nominal area)FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 25 mm dia and 1.5 mm wall thickness and conduit fittings including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc ; Complete all as specified and directed by Engineer-in-charge.for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.) One socket outet point 5 amps on the independent board.
All as Ser item here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
Supply and Fixing of switch piano flush button single pole one-way 5 Ampere ; Complete all as specified and directed by Engineer-in-charge
Supply and fixing of switch piano flush button single pole two-ways 5 Ampere ; Complete all as specified and directed by Engineer-in-charge
Supply and fixing of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC ; Complete all as specified and directed by Engineer-in-charge
Supply and fixing of switch piano flush button single pole one-way 15 Ampere ; Complete all as specified and directed by Engineer-in-charge
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular switch 6 Amp 1 way 1 module size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular switch 6Amp 2 way 1 module size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular switch 16 Amp 1 way with indicator 1 module size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular socket shuttered 6 Amp 2/3 pin combined 2 module size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular socket 16Amp multipurpose type 2 module size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Modular Fan regulator step type 120 watts 2 Module size ; Complete all as specified and directed by Engineer-in-charge Note : Make for Item No 17 to 22 are LEGRAND(Arteor),, CRABTREE(Verona), SCHNEIDER (Zencel), ANCHOR (Vision)
Supply and Fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings ; Complete all as specified and directed by Engineer-in-charge
Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing bell push, flush type, single pole 5 amps ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing metal enclosure (plug & socket type DB) complete including single pole and neutral enclosure with two pin, earth plug and socket complete with one SP MCB C Curve type of capacity 20 Amp, 10 KA ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing MCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing MCB double pole higher rating, 240 volts, 100 Ampere, rupturing capacity 10 KA, ‘C’ curve type ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 4 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way with IP-43 and IK-09 protection, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc ; Complete all as specified and directed by Engineer-in-charge. Make (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
Supply and Fixing MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and incl 100 amp 36 kA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% including Suitable type MCB with blank plate including taking down old MCCB all as specified and directed ; Complete all as specified and directed by Engineer-in-charge. (Note : The cost of removing old wooden/steel box etc and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical medium grade PVC conduit not less than 20 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge NOTE: 3 single core 6 sqmm and PVC conduit shall be measured as one RM.
Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge NOTE: 3 single core 10 sqmm and PVC conduit shall be measured as one RM.
Supply and Fixing wall /ceiling mounting LED 18 Watt pride plus/smart line tube light fitting complete with all acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing in repairs wall /ceiling mounting LED 9 Watt tube light fitting complete with all acessories 1x9 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing decorative Gate light fitting made up of high grade unbreakable polycarbonate material suitable for 9 watt LED lamp (B-22 base) including one Nos LED bulb 9 watt with complete acessary ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing energy saving new generation 10 watt LED built up, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection ; Complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement of security light fitting LED 45 (dusk & down sensor) Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.5 sq mm including GI pipe 32 mm dia 1 mtr long bend to shape (light grade) from celing rose to fitting terminal including taking down old CFL security light fitting ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing fan regulator electronic step type & socket size and making all necessary connections ; Complete all as specified and directed by Engineer-in-charge
Material and Labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note : - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Earthing work will be done by contractor ub presence of JE /Engr-in-Charge, the earthing work carried in absence JE /Engr-in-Charge will not neasured & paid for the same. (iv) All earthing material will be approved before bulk procurement and got approved from Engr-in-Charge
Supply and Fixing in repairs ceiling mounting fitting LED type 36 W fitted in 2x2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fitting ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing 25 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable ; Complete all as specified and directed by Engineer-in-charge
Material and labour service connection PVC cable 10 Sqmm 2 Core incl GI wire and PVC conduit for fixing in wall /pole incl connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing LED flood light fitting 50 Watt with high pressure die cast housing IP65 protection single phase supply including connection with PVC wire ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing post top lantern LED fitting 15 Watt including LED bulb high grade unbreakable polycarbonate suitable for LED bulb including connection with PVC wire ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting 25/45/60 Watt including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing bell push, Module type, single pole 5 amps complete ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing LED Blub 9 Watt pin type 220 Volts including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Ceiling light fitting 12 Watt as per sample including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing LED Blub Thread 9 Watt threat type 220 Volts including connection ; Complete all as specified and directed by Engineer-in-charge
Material and Labour for binding of loose wire in any numbers /of any size by using cable ties and cable clips flexible PVC pipes and PVC casing and caping of suitable size as required on site ; Complete all as specified and directed by Engineer-in-charge Note : Flexible PVC pipe and casing and caping will be measured and paid separtely.
Supply and Fixing PVC ISI marked medium grade pipe 25 mm dia including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing flexible pipe 25 mm dia including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Casing /Caping 25 mm dia including connection ; Complete all as specified and directed by Engineer-in-charge
Supply and Fixing Casing /Caping 20 mm dia including connection ; Complete all as specified and directed by Engineer-in-charge Notes for Srl Item No.1 to 52of DCS (i) The above said work is based on daily complaint based work and Contractor has to take daily complaint from MES complaint cell from Concern JE E/M on Daily Basis (Except Sunday & holiday).(ii) Contrcator has to attend the complaint within 24 Hrs after recived complaint from JE E/M.(iii) Contrctor has to provide the Mobile number of their Engineer or supervisor to oncerned JE E/M so that messges of complaint can also be send on the same mobile number.(iv) For non collection of daily complaits from JE E/M Rs.500/- per day will be recovered from contractor's dues. (v) For Non attendence of complaints within 24 Hrs Rs.200/- per day per complaint will be recovered from contractor's dues.(vi) Contractor or of their Engineer or supervisor has to return the complaint duly signed from the user within time & date to JE EM . (vii) The make/manufacturer shall be approved by the GE before incorporation in the work as per Appendix 'B' to Particular specification section-II of tender.
SUN MANN ENGINEERS
Saini Constructions
kailu construction co
M/s Vijay Construction Co.
Santokh Singh and Associates
HARPAL ENGINEERS AND BUILDERS
Rishi Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .