Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAdmitted-Finance | ₹4.9 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S BAJRANG ELECTRICALS L1 |
|---|---|---|---|---|
| 1.00 | Regular Operation and Maintenance of LED Street light fixtures (upto 100 watt) on poles with material like chawk tube road starter side holder wiring etc of Ind area Malpura Distt. Tonk for Maintenance of LED Street light fixtures (upto 100 watt) including supply and replacing the required material and labour etc complete as per the following terms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | 1,920 | per point per month | 85 ₹1,63,200 Lowest |
| 2.00 | Regular Operation & maintenance of high mast lights (with all material & labour etc.) at different locations of Industrial area Malpura as per directions of Engineer-In-Charge and as per enclosed terms & conditions. The work includes timely switching on/off of high mast lights, replacing of spare parts, wiring, high mast light fixtures(including bulbs, ballast, ant other machinery etc.) as & when required. The scope of work also includes removal of all types of faults in panels and other accessories etc complete so as to keep the high mast lights of the area functional. (Each high mast lighting system consist of approx. 20m height structural Mast with 12 nos luminaries having 2 nos single ended 400watt LED street light fixture each.)erms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | 24 | Per high mast per month | 4,800 ₹1,15,200 Lowest |
| 3.00 | Regular Operation and Maintenance of LED Street light fixtures (upto 100 watt) on poles with material like chawk tube road starter side holder wiring etc of Ind area Newai(Old), Distt. Tonk for Maintenance of LED Street light fixtures (upto 100 watt) including supply and replacing the required material and labour etc complete as per the following terms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | 1,080 | per point per month | 85 ₹91,800 Lowest |
| 4.00 | Regular Operation & maintenance of high mast lights (with all material & labour etc.) at different locations of Industrial area Newai (Old) as per directions of Engineer-In-Charge and as per enclosed terms & conditions. The work includes timely switching on/off of high mast lights, replacing of spare parts, wiring, high mast light fixtures(including bulbs, ballast, ant other machinery etc.) as & when required. The scope of work also includes removal of all types of faults in panels and other accessories etc complete so as to keep the high mast lights of the area functional. (Each high mast lighting system consist of approx. 20m height structural Mast with 12 nos luminaries having 2 nos single ended 400watt LED street light fixture each.)erms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | 24 | Per high mast per month | 4,800 ₹1,15,200 Lowest |
Tender Value
₹3.8 L
EMD Value
₹7,500
Closing Date
24 Aug 2026, 5:00 pmClosed
UNIT HEAD
UNIT OFFICE SAWAI MADHOPUR
Regular operation and maintenance of street lights at Ind. Area Malpura and Newai Old.
2026_RIICO_587844_3
RIICO/SWM/2026-2027/NIT NO.- 31
Open Tender
Civil Works
Percentage
365 days
INDUSTRIAL AREA MALPURA AND NEWAI OLD
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
RIICO
₹7,500
Yes
8 Sept 2026
14 Aug 2026
25 Aug 2026
14 Aug 2026
24 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Regular Operation and Maintenance of LED Street light fixtures (upto 100 watt) on poles with material like chawk tube road starter side holder wiring etc of Ind area Malpura Distt. Tonk for Maintenance of LED Street light fixtures (upto 100 watt) including supply and replacing the required material and labour etc complete as per the following terms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | - | per point per month | - | - |
| 2 | Regular Operation & maintenance of high mast lights (with all material & labour etc.) at different locations of Industrial area Malpura as per directions of Engineer-In-Charge and as per enclosed terms & conditions. The work includes timely switching on/off of high mast lights, replacing of spare parts, wiring, high mast light fixtures(including bulbs, ballast, ant other machinery etc.) as & when required. The scope of work also includes removal of all types of faults in panels and other accessories etc complete so as to keep the high mast lights of the area functional. (Each high mast lighting system consist of approx. 20m height structural Mast with 12 nos luminaries having 2 nos single ended 400watt LED street light fixture each.)erms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | - | Per high mast per month | - | - |
| 3 | Regular Operation and Maintenance of LED Street light fixtures (upto 100 watt) on poles with material like chawk tube road starter side holder wiring etc of Ind area Newai(Old), Distt. Tonk for Maintenance of LED Street light fixtures (upto 100 watt) including supply and replacing the required material and labour etc complete as per the following terms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | - | per point per month | - | - |
| 4 | Regular Operation & maintenance of high mast lights (with all material & labour etc.) at different locations of Industrial area Newai (Old) as per directions of Engineer-In-Charge and as per enclosed terms & conditions. The work includes timely switching on/off of high mast lights, replacing of spare parts, wiring, high mast light fixtures(including bulbs, ballast, ant other machinery etc.) as & when required. The scope of work also includes removal of all types of faults in panels and other accessories etc complete so as to keep the high mast lights of the area functional. (Each high mast lighting system consist of approx. 20m height structural Mast with 12 nos luminaries having 2 nos single ended 400watt LED street light fixture each.)erms and conditions1 At any moment a minimum of 90 percentage of total fixture must be in order. The defective fixture must be repaired within 3 days falling Which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor.2 Contractor shall arrange at his cost for put on off the street light fixture at appropriate time regularly as per instructions of Engineer In charge. A register shall be maintained at RIICO or Association office and complaint lodged must be attended by contractor within 24 hours. The person deputed by contractor shall attend the RIICO or Association office daily and comply the instructions and attend complaints regularly.3 Contractor will have to employ trained and qualified electricians for the work.4 Corporation will not be responsible for any kind of accident during execution of work.5 Contractor will be responsible for safety and security of fixtures and all concerned materials.6 Contractor will be responsible for arrangement of all T and P required for the work.7 Cost of all labour and material like tube rod starter ballast HPSV lamp or ballast wire will be borne by contractor. All material required for the work shall not be below the category II of concerned BSR item. Contractor has to repair and maintenance of fixture with material in all cases like short circuit phase to phase of JVVNL line etc.8 No extra payment will be made for fixing or removal of extra or existing fixture in the industrial area.9 Contractor will be responsible for timely collection and deposition of electric bills of areas in each month In case of delay in payment and JVVNL impose surcharge for delay payment the same will be recovered from the running bill of the contractor Payment of electricity bill will be made by RIICO.10 Contractor will be responsible for rebate of Timer provided by JVVNL Hence contractor will maintain the On and Off system by timer properly In case no rebate is provided by JVVNL due to failure of timer then rebate will be deducted from contractor payment.11 Contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. In case of any theft is found suitable penalty will be imposed on the contractor.12 Contractor will maintain cubical panel board and accessories fitted in it In case of any fault repair or replace of material will be done by the contractor at his own cost. No extra payment will be made on behalf of material.13 Contractor has to keep ready total fixtures In case of fault of fixture a penalty of Rs 100 per fixture per day will be imposed on the contractor. | - | Per high mast per month | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
termsandconditionsstreetlight.pdf
Other Document • 0.21 MB
TDSTREETLIGHT.pdf
Tender Documents • 2.66 MB
BOQ_1044054.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .