Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | ₹19.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹22.8 L+₹2.9 L (14.7%)Rejected-AOC | ₹22.8 L+₹2.9 L (14.7%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹28.1 L+₹8.2 L (41.5%)Rejected-AOC | ₹28.1 L+₹8.2 L (41.5%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹29.4 L+₹9.6 L (48.4%)Rejected-AOC | ₹29.4 L+₹9.6 L (48.4%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹30.1 L+₹10.3 L (51.7%)Rejected-AOC | ₹30.1 L+₹10.3 L (51.7%) | L5 | Rejected-AOC Rejected |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
23 Mar 2023, 6:00 pmClosed
GE (I) Campbell Bay
GE (I) Campbell Bay, Army land, Campbell Bay, Great Nicobar-744302
SPL REPAIR TO CERTAIN LT SWITCH GEAR EQUIPMENTS AND CONNECTED MISC E/M WORKS AND SPL REPAIR TO HARD STANDING AT INS BAAZ UNDER GE (I) CAMPBELL BAY
2023_MES_577339_2
8051/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹38,000
5 Apr 2023
3 Mar 2023
25 Mar 2023
3 Mar 2023
23 Mar 2023
10 Mar 2023
Amount
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in soft/ loose soil complete all as specified and as directed Engineer-in-Charge.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.
Removing excavated/ demolished material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point.
M&L 100 mm thick cement concrete 1 : 2 : 4 type B-1 (using 20mm graded crushed stone aggregate) laid in base, cement concrete surface even and smooth w/o using extra cement.
M & L for forming Contraction (Dummy) joints 65mm deep X 10mm wide, filled with cealing compound grade 'B' complete all as speciefied
M & L Galvanised iron tubing 100 mm dia light grade laid in trenches/floors/walls/under ground for eath lead protection and cables at road crossing etc complete all as specified and directed. Make : Tata / Bansal / Jindal or equivalent
S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc for protection of HT UG cable all as specified and directed.
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of of suitable size, 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 Core in and out(Panel board shall have sufficent space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 type C1, including taking dow old u/s one comeplete and consisting the following provisions:- (a) MCCB 400Amps Four Pole AC 415 Volts,50Hz,36kA , Adjustable Thermal & fixed Magnetic settings, - 01 No(incoming) (b) Aluminium Busbar 600 Amps with Sleeves -04( three phase with neutral and connectors set of 4 (c) Indicator lamp set of 3 - 01 Set (d) Control wiring with PVC insulator multistranded copper conductor, insulators for busbar mounting 3 Nos of suitable CT's and accessories - 01 Set (e) Digital Type multi dislay VAF+PF cl-0.5 accuracy-01 No (f) Insualtors:SMC/DMC
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of of suitable size, 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 Core in and out(Panel board shall have sufficent space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 type C1, including taking dow old u/s one comeplete and consisting the following provisions:- (a) MCCB 125Amps Four Pole AC 415 Volts,50Hz,25kA , Adjustable Thermal & fixed Magnetic settings, - 01 No(incoming). (b) MCCB 100 Amps 3Pole ,AC, 50Hz 415 Volts,25kA -01Nos(outgoing) (c) MCCB 32-63 Amps 3Pole ,AC, 50Hz 415 Volts,16kA -02Nos(outgoing+spare) (d) Aluminium Busbar 200 Amps with Sleeves -04( three phase with neutral and connectors set of 4 (e) Indicator lamp set of 3 - 01 Set (f) Control wiring with PVC insulator multistranded copper conductor, insulators for busbar mounting 3 Nos of suitable CT's and accessories - 01 Set (g) Digital Type multi dislay VAF+PF cl-0.5 accuracy-01 No (h) Insualtors:SMC/DMC
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as requied 25X6mm galvanised iron strip including taking old un serviceable one.
Supply,test,install & commsissioning of Bus bar chambers(including 4 bus bars i.e R,Y,B and neutral),3-Ph with netral,1100volts,50Hz including suitable sheet metal enclosure along with necessary screws,nuts,bolts and other Misc accessroies and making connections(input &out put) with cable terminal ends complete for the following current carrying capacities,Panel mounted on suitable size & thickness of angle iron frame(proper mounting shall be done) duly painted and embeded in necessary required quatnity of PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level complete and consisting the following provisions:- (a)4-Way, 200 Amps
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade(earthed), 3.5 core 185 sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc all as specified and directed by Engr-in-Charge :-
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade(earthed), 3.5 core 150 sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc and directed by Engr-in-Charge :- Make : Polycab / Gloster / Havells / Finolex or equivalent
Note : An amount of Rs 2,825.00 towards Schedule of Credit shall be deducted to arrive the contract sum.
KCM BUILDERS & CONSTRUCTIONS (INDIA) PVT.LTD
MAHESWARI CONSTRUCTIONS
RSL Construction
M/S PANNER SELVAM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .