Loading…
Loading…
Tender ID
Tender Value
₹5.9 L
Closing Date
20 Feb 2026, 6:00 pmClosed
Executive Engineer REW Shopian
Executive Engineer REW Shopian
Providing Electrification for Tehsil Office Chitragam Shopian
2026_RDPR_302459_1
E-Nit 128 of 2025-26
Open Tender
Electrical Works
Percentage
60 days
Shopian
Please refer Tender documents.
4 documents required · 4 mandatory
₹300
Rural Development and Panchayati Raj
Exempted
6 Feb 2026
6 Feb 2026
21 Feb 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
Wiring for light point(72)/fan point(14)/exhaust fan point(5) with 1.5.sq.mm FRLS PVC insulated copper conductor single core cable in existing surface/recessed medium class PVC Conduit, with modular switch(Anchor roma urban/eq.make), Suitable Gl Box for Switches with base plate and Cover Plate and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required (Havells/Legrand/roma urban/Eq.make as par ISI Standard Note The Gl box can be of different sizes of Modulues to hold the Modular Cover Plates and Modular Switches for lights/fans/exhaust fans and are included in the point
Supply, fixing, drawing testing and commissioning of 4x16+1x6 sqmm FRLS PVC insulated copper conductor (Havells/Anchor/Eq.make), single core cable with lugs in existing surface /recessed medium class PVC conduit (Heating Circuit from Main Panel to MCB DB)
Supply, fixing, drawing testing and commissioning of 4x6+1x6 sqmm FRLS PVC insulated 3 copper conductor (Havells/Anchor/Eq.make), single core cable with lugs in existing surface /recessed medium class PVC conduit (Lighting Circuit from Main Panel to MCB DB)
Supply drawing, fixing testing and Commissioning of 3x2.5 sqmm FRLS PVC insulated copper conductor (Havells/Anchor/Eq.make), single core cable in existing surface/recessed medium class PVC channel From MCB DB to Switch Board of Lighting Points/6 amp Switch Sockets/Inverter
Supply drawing, fixing testing and Commissioning of 3x4 sqmm FRLS PVC insulated copper 5 conductor (Havells/Anchor/Eq.make), single core cable in existing surface/recessed medium class PVC Channel From MCB DB to 16 amp Switches/Sockets
Supply drawing, fixing testing and Commissioning of 3x6 sqmm FRLS PVC insulated copper conductor (Havells/Anchor/Eq.make), single core cable in existing surface/recessed medium class PVC Channel From MCB DB to ACS
Supply of fixing of 25/32 size PVC condute along with accessorles(bends, sockets, iron staples/saddles/screws,pvc fastener etc) in surface /recess include in cutting the wall and making good the same by cement sand and paint of same color as existing in the building as required for Walls
Supply and Fixing of MS deep Junction Box 3"/5" for LED Lights and Fans
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in 9 recess including providing and fixing of 6 pin 5/6 amp and 15/16 amp/230 V AC modular socket and 15/16 amp modular switch(Anchor Ro urban/SSK NV/Havells/Eq.make)
Supply of fixing of Suitable Gi Box with Modular Plate and cover in front on surface or in 10 recess including providing and fixing of 3 pin 5/6 amp/230V AC modular socket and 5/6 amp modular switch(Anchor Ro urban/SSK NV/Havells/Eq.make)
Supply of fixing of DP Sheet steel enclosure on surface/recess alongwith 25/32 A 240 V C curve DP MCB complete with connections testing and comm as required for ACs
DP MCB complete with connections testing and comm as required for ACs Supply installation testing and commissioning of 1200 mm dia sweep, ceiling fan with 2 No12 Canopies, shackle kit safety rope Cu winding, steel/al body, pf not less than 0.9 etc Havalles make/Bajaj/Crompton(Flavia)of eq standard
Supply of fixing of 6 amp/230 V AC fan dimmer step type 2 modules with cover plateAnchor Ro urban/SSK NV/Havells/Eq.make.
SITC of 200-250 mm dia Sweep Exhaust fan made of Powder coated metal with ceiling rose of standard make
S/F testing nd comm..of recessed/surface mounted 12 watt LED down lighters SMD type 15 system Luman efficacy >= 105<120 Im/watt Philips/havalles/bajaj/Crompton make of eq. standards
SITC of 20 watt LED bulk lights of standard make (Complete Job)
S/F testing nd comm.. of 18-22 watt LED Batten lights (4ft) SMD type system Luman efficacy >=105-120 Im/watt Philips/havallies/bajaj/Crompton make of eq, standards
Suppling and fixing of 6(4+18) /24way horizontal type Three pole and neutral sheet steel, MCB distribution board, 415 V, On surface/recess, complet with tinned cu bus bar neutral bus bar, earth bar, din bar interconnection, powder painted including earthing etc.as required.(Eutwith out mcb/Rccb/Isolator) -Hager/Legrand/ssk/equt.standard
SITC of 415 V 63 amp TPN MCB C Curve in the existing MCB DB 20
S/F testing and comm.. of MCB of the below mentioned capacities in sub main control legrand C curve series 6-32 Amp SP MCB
S/F testing and comm. of MCB of the below mentioned capacities in sub main control legrand C curve series 40-63 Amp DP MCB
Supply installation testing and comm. Of 3 phase 415 V 200 ampere Bus Bar Tap off Box metal 22 enclosed inclusive of 200 amp 4 strip Al bus bar 1 No.(3 for phases, 1 for neutral)
Suppling and fixing of 4 way (4+12) Vertical type Three pole and neutral sheet steel, MCB distribution board, 415 V TPN MCB DB, On surface/recess, complete with 200 amps Tinned cu bus bar, neutral bus bar, earth bar, din bar interconnection, powder painted including earthing etc as required (But with out mch/Rccb/Isolator):-Hager/Legrand/ssk/equt.standard
SITC of 100 Amp FP MCCB 30 kA including spreader links including spreader links, icu=ics=100% 24 Adjustable thermal and Adjustable magnetic release) Legrand/Schnider/Seimens make.
25 SITC of MCB 63 A 4P,10 KA C Curve
SITC of MCB 32 A.10 kA DP C Curve
Supply laying partly overhead partly underground, testing and commissioning of 16sqmm 27 Four Core Al Armoured cable of standa'ds make
Supplying, installation, Testing & Commissioning of 6 kVA at full load (Unity Power Factor ON UNE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank sultable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Containerjand Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation)Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (THD)/total28 demand distortion (TDD) on the input grid shall be<5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input of to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shallbe kva rating x 1 however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitablefor incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase220/230/240 Volt, 50 Hz +/-0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operatingtemperature 0 to 40 DC, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc.UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part land Part 2, it shall be aVoltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3).
Earthing with Gi earth Pipe 2.15 metre long(2. Nos),40 mm dia induding and providingMasonary Enclosure with cover plate having locking arrangement and watering pipe etc with 29 charcoal/coke/salt as required along with 25X3 mm Gt Strp upto the nearest point of earth to be supplied/drawn from Main Power' distribution Board and connecting the same (Complete banner the directions of eneineer Incharge
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_981532.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .