Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹80.4 L+₹8.1 L (11.2%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹89.9 L+₹17.6 L (24.4%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹92.8 L+₹20.5 L (28.4%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹94.8 L+₹22.5 L (31.2%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | AGRAWAL ASSOCIATES L5 | M/S Anil Enterprises L7 | Horizon Construction L2 | Rama Electricals L4 | Accurate Power Systems L8 | M/S N K POWER SYSTEMS AND PROJECTS L1 | Vishwas Electricals And Sons L6 | Roy and Sons Infrastructures L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix cable jointing kit for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm11 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories . | 27 | Each | 3,000 ₹81,000 Lowest | 4,000 ₹1,08,000 | 3,006 ₹81,162 | 3,000 ₹81,000 Lowest | 5,700 ₹1,53,900 | 4,444 ₹1,19,988 | 6,700 ₹1,80,900 | 5,000 ₹1,35,000 |
| 2.00 | "M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of strata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. including taking down old unserviceable earthings. | 20 | Each Set | 3,500 ₹70,000 Lowest | 8,900 ₹1,78,000 | 5,103 ₹1,02,060 | 4,000 ₹80,000 | 8,500 ₹1,70,000 | 6,666 ₹1,33,320 | 8,800 ₹1,76,000 | 8,000 ₹1,60,000 |
| 3.00 | Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having two incoming and two out going connections (4 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 02 No isolator as incomer and 02 nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted) | 2 | Each Job | 9,50,000 ₹19,00,000 | 11,18,000 ₹22,36,000 | 8,42,400 ₹16,84,800 | 9,71,126 ₹19,42,252 | 10,00,000 ₹20,00,000 | 7,37,708 ₹14,75,416 Lowest | 10,00,000 ₹20,00,000 | 11,40,000 ₹22,80,000 |
| 3.01 | Item No 3 Contd/.. The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a) Vacuum circuit breaker module having thee position switch, OFF load (connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d) Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3 core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A | - | - | - | - | - | - | - | - | - | - |
| 4.00 | Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having one incoming and two out going connections (3 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 01 No isolator as incomer and 02 nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted) | 1 | Each Job | 9,90,000 ₹9,90,000 | 10,00,000 ₹10,00,000 | 7,78,500 ₹7,78,500 | 8,56,547 ₹8,56,547 | 8,50,000 ₹8,50,000 | 5,99,521.73 ₹5,99,521.73 Lowest | 8,65,000 ₹8,65,000 | 7,70,750 ₹7,70,750 |
| 4.01 | Item No 4 Contd/... The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a0 Vacuum circuit breaker module having thee position switch, OFF load(connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d0 Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A | - | - | - | - | - | - | - | - | - | - |
| 5.00 | Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having one incoming and Three out going connections (4 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 01 No isolator as incomer and 03 Nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted) | 3 | Each Job | 10,75,000 ₹32,25,000 | 12,55,000 ₹37,65,000 | 9,62,100 ₹28,86,300 | 11,06,250 ₹33,18,750 | 12,50,000 ₹37,50,000 | 8,77,777 ₹26,33,331 Lowest | 11,40,000 ₹34,20,000 | 13,00,000 ₹39,00,000 |
| 5.01 | Item No 5 Contd/... The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400/630 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a) Vacuum circuit breaker module having thee position switch, OFF load (connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d) Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3 core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A | - | - | - | - | - | - | - | - | - | - |
| 6.00 | Supplying, installing, testing and commissioning of AC 3 phase 50 HZ 250 KVA capacity Level-2 transformer step down, outdoor type 11000/433 volts (at no load) double copper wound, oil immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of +/- 2.5 %or +/-5% or +/- 7.5% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings. | 2 | Each | 13,75,000 ₹27,50,000 | 13,70,000 ₹27,40,000 | 10,08,000 ₹20,16,000 | 12,73,220 ₹25,46,440 | 20,50,000 ₹41,00,000 | 9,09,999.5 ₹18,19,999 | 12,80,000 ₹25,60,000 | 5,30,000 ₹10,60,000 Lowest |
| 7.00 | Dismantling of old unserviceable 4 pole structure along with GOD, Dos, LA and anti climbing Device by breaking the PCC plinth of four pole structure and keeping in safe custody for taking as schedule of credit. | 6 | Job | 1,000 ₹6,000 | 7,000 ₹42,000 | 450 ₹2,700 Lowest | 500 ₹3,000 | 4,000 ₹24,000 | 3,333 ₹19,998 | 35,000 ₹2,10,000 | 5,000 ₹30,000 |
Tender Value
₹85.2 L
EMD Value
₹1.5 L
Closing Date
15 Jul 2025, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH) - 422401
AS PER TENDER DOCUMENTS
2025_MES_713010_1
86018/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEOLALI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE DEOLALI
₹1.5 L
Yes
18 Sept 2025
6 Jun 2025
22 Jul 2025
6 Jun 2025
15 Jul 2025
27 Jun 2025
7 Jun 2025 - 16 Jun 2025
Amount
Supply and fix cable jointing kit for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm11 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories .
"M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of strata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. including taking down old unserviceable earthings.
Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having two incoming and two out going connections (4 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 02 No isolator as incomer and 02 nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted)
Item No 3 Contd/.. The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a) Vacuum circuit breaker module having thee position switch, OFF load (connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d) Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3 core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A
Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having one incoming and two out going connections (3 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 01 No isolator as incomer and 02 nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted)
Item No 4 Contd/... The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a0 Vacuum circuit breaker module having thee position switch, OFF load(connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d0 Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A
Supply, installation, test & commissioning of SF6 gas insulated circuit breaker HT 11KV, 3 phase, 50 cycle totally enclosed metal clad of 3 mm thickness, high tensile steel with zinc coating outdoor type floor mounting having one incoming and Three out going connections (4 way RMU ) with internal copper bus bar of rating 630 Amps, consisting of 01 No isolator as incomer and 03 Nos VCBs with self powered relay as out going. All connections of RMU should be enclosed in one tank to avoid multiple interconnections sealed for life robotically welded non magnetic and non ferrite 304 grade stainless steel tank of 3 mm thick having IP-67 protection filled with SF6 gas with leakage rate less than 1% per year tested as per IEC 62271-200. The earthing bus bar shall be provided through out the length of switch gear with all acessories such as terminal boots, VPIS and mechanical indications for VCBs for ON/OFF. (civil work & foundation is deemed to be included in rate quoted)
Item No 5 Contd/... The complete enclosure of switch gear shall be of IP-54. The outer of enclosure shall cover entire front part of swith gear incl cable compartment, over load relays digital ammeter, volt meter and rating upto 400/630 Amps complete incl PCC plateform for mounting the switch gear complete with following accessories. (a) Vacuum circuit breaker module having thee position switch, OFF load (connected in series with VCB). (b) Insulation medium- SF6 gas. (c) Arc quenching- Vacuum type. (d) Short time current-20KA/3 sec (e) Making cap- 50KA, (F) Cable box should be front side, air insulated suitable upto 3 core 150 sqmm,11 KV cable. (g) Temparature as per IEC 62271-200 (h) CT to be ring type LVCB (j) PT to be non disconnecting stud type (k) Lifting lugs (i) Gas pressure indcator (m) VCBs rating 400/630 A
Supplying, installing, testing and commissioning of AC 3 phase 50 HZ 250 KVA capacity Level-2 transformer step down, outdoor type 11000/433 volts (at no load) double copper wound, oil immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of +/- 2.5 %or +/-5% or +/- 7.5% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings.
Dismantling of old unserviceable 4 pole structure along with GOD, Dos, LA and anti climbing Device by breaking the PCC plinth of four pole structure and keeping in safe custody for taking as schedule of credit.
Supplying, fixing, jointing and testing heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 120 sqmm , 3 core , complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm.
Supply & lay in trenches double walled corugated HDPE pipe 110 mm dia for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F in replacement RCC rout marker/indicator of size 0.3mtr x 0.15 mtr x 1.5 mtr complete including embossing " HT CABLE" painting with one coat of primer and two coats of oil paint as per colour coding specified and directed by Engr-inCharge for exposed surfaces, excavation,PCC1:2:4 etc included in this item rate complete all as specified and directed by Engr-in- Charge.
Horizon Construction (BID ID -3351205)
Roy and Sons Infrastructures (BID ID -3359919)
Rama Electricals (BID ID -3351472)
AGRAWAL ASSOCIATES (BID ID -3350714)
Vishwas Electricals And Sons (BID ID -3359126)
M/S Anil Enterprises (BID ID -3351180)
Accurate Power Systems (BID ID -3359917)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .