Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹34.5 L+₹2.6 L (8.06%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹37.5 L+₹5.5 L (17.3%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹41.0 L+₹9.1 L (28.4%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L4 | Rejected-Finance Higher amount quoted |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
19 Sept 2020, 6:00 pmClosed
CWE A Jaisalmer
CWE A Jaisalmer
REPAIR AND MAINT OF HT UG CABLE/OH LINE,TRANSFORMER,VOLTAGE STABLIZER AND ALLIED WORKS IN CERTAIN AREA MIL STN JAISALMER UNDER GE (A) JAISALMER
2020_MES_370445_1
83844
Open Tender
Electrical and Maintenance Works
Works
270 days
GE A Jaisalmer
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE(A) JAISALMER
₹70,000
Yes
20 Jan 2021
19 Aug 2020
21 Sept 2020
19 Aug 2020
19 Sept 2020
3 Sept 2020
Amount
Taking down and dismounting defective transformer 33/11 KV of capacity 0.750 MVA to 1.6 MVA from foundation by using crane and transporting to workshop or factory at Jodhpur city area (authrorised for such repair) for repair after disconnecting HV, LV side HT cable or HT aluminium conductor, dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 33/11 KV of capacity 2.0 MVA to 5.0 MVA from foundation by using crane and transporting to workshop or factory at Jodhpur city area (authrorised for such repair) for repair after disconnecting HV, LV side HT cable or HT aluminium conductor, dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back workshop Jodhpur to site, installation on plate form, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 25 KVA to 63 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jaisalmer city (authrorised for such repair) fo repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 75 KVA to 160 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jaisalmer city (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 200 KVA to 630 KVA from foundation/ pole by using crane and transporting to workshop or factory at Jaisalmer city (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting back from workshop Jodhpur to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. NOTE FOR SER ITEM NO.1 TO 5 :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
Supply only synthetic rubberised gaskets suitable for top cover of 33/11 KV power transformer of capacity 0.750 MVA to 1.6 MVA complete all as specified .Make : As per Sample
All as per ser item No 6 above but capacity of power transformer 2 MVA to 5 MVA complete all as specified and directed at site.Make : As per Sample
All as per ser item No 6 above but capacity of 11/0.433 KV 25 KVA to 160 KVA complete all as specified and directed at site.Make : As per Sample
All as per ser item No 6 above but capacity of 11/0.433 KV 200 KVA to 630 KVA complete all as specified and directed at site.Make : As per Sample
Supply only synthetic rubberised gaskets suitable for HT bushing of 33/11 KV power Transformer of capacity 0.750 MVA to 1.6 MVA complete all as specified .Make : As per Sample
All as per ser item No 10 above but capacity of power transformer 2 MVA to 5 MVA complete all as specified and directed at site.Make : As per Sample
All as per ser item No 10 above but capacity of 11/0.433 KV 25 KVA to 160 KVA complete all as specified and directed at site.Make : As per Sample
All as per ser item No 10 above but capacity of 11/0.433 KV 200 KVA to 630 KVA complete all as specified and directed at site.Make : As per Sample
Supply only synthetic rubberised gaskets suitable for LT bushing of 11/0.433 KV Transformer of capacity 25 KVA to 160 KVA complete all as specified .Make : As per Sample
All as per ser item No 14 above but capacity of 11/0.433 KV 200 KVA to 630 KVA complete all as specified and directed at site.Make : As per Sample
M&L for taking out unserviceable core and limb and HT/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material in any location complete for transformer 33/11 KV (Power Transformer) all as specified & directed by Engineer-in - Charge.
M&L for taking out unserviceable core and limb and HT/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 630 KVA in any difrence location complete all as specified & directed by Engineer-in - Charge.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge.(Note : For any capacity of Transformer)
M&L in repair of unserviceable HT brass stud of transformer 63 KVA to 500 KVA complete all as specified & directed by Engineer-in - Charge.Make : As per Sample
M&L in repair of unserviceable LT brass Stud with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.Make : As per Sample
M&L in repair of unserviceable LT brass Stud with nuts, washers of transformer 11/0.433 KV of capacity 200 KVA to 500 KVA complete all as specified & directed by Engineer-in - Charge.Make : As per Sample
Supply and fix in replacementr of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 25 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.Make : As per Sample
Supply and fix in replacementr of unserviceable breather assembly with silica gel of transformer 11/0.433 KV of capacity 200 KVA to 600 KVA complete all as specified & directed by Engineer-in - Charge.Make : As per Sample
Supply & Fix in repair of transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, CTs 33 KV and PTs 33 KV outdoor type factory sealed with test certificate in any location complete all as specified & directed by Engineer-in - Charge. Make: Savita/Servo/\/ Power Oil.
Supply & Fix in repair of winding tempreture indication gauge anlog type complete suitable for transformer 33/11 KV, 11/0.433 KV complete all as specified & directed by Engineer-in - Charge. Make:- PRECIMEASURE CONTROLS PVT, Ltd or equivalent approved make
Supply & Fix in repair of oil tempreture indication gauge anlog type complete suitable for transformer 33/11 KV, 750 to 1600 KVA all as specified & directed by Engineer-in - Charge. Make:- PRECIMEASURE CONTROLS PVT, Ltd or equivalent approved Make)
Supply & Fix in repair of porcelain transformer bushing 36 KV suitable for transformer 750 to 5000 KVA complete all as specified & directed by Engineer-in - Charge. Make:- Jayshree, Jaipuria Brothers
Supply & Fix in repair of porcelain transformer bushing 12 KV suitable for transformer 750 to 5000 KVA complete all as specified & directed by Engineer-in - Charge. Make:- Jayshree, Jaipuria Brothers
Supply & Fix in repair of porcelain transformer bushing 1.1 KV suitable for transformer up to 250 KVA complete all as specified & directed by Engineer-in - Charge. Make: Jayshree/Jaipuria Brothers
Supply & Fix in repair of porcelain transformer bushing 1.1 KV suitable for transformer up to 400/500 KVA complete all as specified & directed by Engineer-in - Charge. Make:- Jayshree/Jaipuria Brothers
Supply & Fix in repair tap changer suitable for 33 KV/11 KV transformer of capacity 750 to 5000 KVA complete all as specified & directed by Engineer-in - Charge. Make : As per Sample
S & F in repair dimmer suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge. Make:- Digitec or equivalent makes
S & F in repair dimmer suitable for voltage stablizer 50 KVA complete all as specified and directed by Engineer-in-Charge. Make:- Digitec or equivalent approved makes
S & F in repair servo motor 3 Kg / Sqcm suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge. (Make :- Apple, Stepsyn).
Supply,jointing and testing outdoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3.5 core, 35 Sqmm to 95 Sqmm of 1100 Volts grade all as per manufacture recommendation complete all as specified and directed.Make :- Dension/M seal/Cab seal.
All as per item No 35 above here-in-before but suitable size for 3.5 core 70 Sqmm to 150 Sqmm.
All as per item No 35 above here-in-before but suitable size for 3.5 core 185 to 300 Sqmm.
S&F in repair PCB suitable for voltage stablizer 75 KVA (3x25) complte all as spcified and directed by Engineer-in-Charge.
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
All as per item No. 39 above m here-in- beforebut of 120 Sqmm to 185 Sqmm 3 core
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
All as per item No. 41 above here-in-before but of 120 Sqmm to 185 Sqmm 3 core.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
All as per item No. 43 above but of 120 Sqmm to 185 Sqmm 3 core.
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete including taking down old pipe all as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of lightening arresters (station type) out door type discharge current 10 KA assembly suitable for 12 KV including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip and including taking down existing lightening arrestors complete all as specified & directed by Engineer-in-Charge.
Opening the binding wire from pin / disc insulator on PCC pole 11 meter long for re-stretching the ACSR conductor, after re-stretching without kinks & bends, binding the pin / disc insulator with appropriate size of aluminium binding wire complete all as specified & directed by Engineer-in- Charge.NOTE: (i) The above work includes clearing/ prooning of tree branches falling around the conductors.(ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from "J" hook or opening nut, bolts of cross arms on PCC pole 11 meter long for re-stretching the galvanised iron earth wire any size, after re-stretching without kinks & bend , binding the "J" hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut, bolts, washers complete all as specified & directed by Engineer-in- Charge.NOTE: (i) Cost of binding wire / nut bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 insulators vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 insulators vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12/09 insulators Horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
S&F in repair, disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 33000 volts grade complete all as specified & directed by Engineer-in-Charge.
S&F in repair, disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 33000 volts grade complete all as specified & directed by Engineer-in-Charge.
Supply, laying along the poles or passing through pipes or laid under floor,trenches or through walls etc jointing and testing it poles linked polythene insulated galvanised strip armoured electric cable 11000 Volts & earthed grade geavy duty with aluminium conductor and overall served with an outer sheathed of PVC of cross sectional area of 95 sqmm x 3 core Make-Havells/ Polycab/ CCI
All as per item No. 56 above here-in-before but of size 185 sqmm x 3 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-Charge.
Dismantling & Taking down old climbing device and fixing for anti climbing device, comprising 2.24 mm dia galvanised steel-2 strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly secured or as orded (clamps measured seperatly all as specified).
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge.(Note : All Hinges fixed in one panel will be considred under one job only )
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc.
NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed.
(ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board.
(iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer.
(iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
Preparation of the old decorated existing external and internal steel surfaces fo feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrpping or by blow stopping as required and applying tow coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
M/s Yash Electrical and Maintenance
SANJOLI CONSTRUCTION COMPANY
Nvimal Engineers and Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .