Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.5 L+₹93,370 (6.00%)Rejected-Finance NEAR PROTHRAPUR COMMUNITY HALL PAHARGAON GARACHARMA POST SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹21.1 L+₹5.6 L (35.8%)Rejected-Finance 10 WARD NO 18 PLOT NO 34 KAMDENU FURNTIURE SIKAR RAJASTHAN 332025 | SIKAR | RAJASTHAN | 332025 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹21.1 L+₹5.6 L (35.8%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹22.3 L+₹6.7 L (43.3%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L4 | Ruchi enterprises L3 | OMVIN ENTERPRISES LLP L1 | D K ENTERPRISES L2 | ACR ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty and applying colour / white wash finish complete all as specified and directed by Engr-in-Charge. | 486 | Per Point | 5 ₹2,430 Lowest | 8 ₹3,888 | 5 ₹2,430 Lowest | 5 ₹2,430 Lowest | 30 ₹14,580 |
| 2.00 | M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including PVC conduit of suitable dia, complete with all conduit accessories, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing One light/ fan/ bell/ exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
Note - All accessories likes modular top cover plate / hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. | 72 | Per Point | 304 ₹21,888 | 290 ₹20,880 | 270 ₹19,440 | 180 ₹12,960 Lowest | 380 ₹27,360 |
| 3.00 | All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge. | 36 | Per Point | 300 ₹10,800 | 270 ₹9,720 | 270 ₹9,720 | 180 ₹6,480 Lowest | 380 ₹13,680 |
| 4.00 | All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge. | 25 | Per Point | 100 ₹2,500 | 200 ₹5,000 | 60 ₹1,500 Lowest | 60 ₹1,500 Lowest | 100 ₹2,500 |
| 5.00 | All as per ser items No. 2.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge. | 2 | Per Point | 300 ₹600 | 200 ₹400 | 270 ₹540 | 180 ₹360 Lowest | 380 ₹760 |
| 6.00 | All as per ser items No. 2.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge. | 54 | Per Point | 289 ₹15,606 | 390 ₹21,060 | 320 ₹17,280 | 250 ₹13,500 Lowest | 480 ₹25,920 |
| 7.00 | M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in existing conduit, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch.complete all as specified and directed by Emgr-in-Charge.
Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. | 63 | Per Point | 300 ₹18,900 | 390 ₹24,570 | 270 ₹17,010 | 180 ₹11,340 Lowest | 380 ₹23,940 |
| 8.00 | All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge. | 30 | Per Point | 300 ₹9,000 | 300 ₹9,000 | 270 ₹8,100 | 180 ₹5,400 Lowest | 380 ₹11,400 |
| 9.00 | All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge. | 15 | Per Point | 100 ₹1,500 | 300 ₹4,500 | 60 ₹900 Lowest | 60 ₹900 Lowest | 100 ₹1,500 |
| 10.00 | All as per ser items No. 7.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge. | 2 | Per Point | 300 ₹600 | 300 ₹600 | 270 ₹540 | 180 ₹360 Lowest | 380 ₹760 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Mar 2025, 6:00 pmClosed
GE E/M RR HOSPITAL
GE E/M RR HOSPITAL DELHI CANTT-10
GE/H-80/2024-2025 NAME OF WORK REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION SUCH AS WIRING SUBMAIN MCBS AND DBS AT AHRR UNDER GE E/M RR HOSPITAL DELHI CANTT-10
2025_MES_699588_1
GE/H-80/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSPITAL
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹50,000
Yes
28 Aug 2025
27 Feb 2025
29 Mar 2025
27 Feb 2025
27 Mar 2025
13 Mar 2025
Amount
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty and applying colour / white wash finish complete all as specified and directed by Engr-in-Charge.
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including PVC conduit of suitable dia, complete with all conduit accessories, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing One light/ fan/ bell/ exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge. Note - All accessories likes modular top cover plate / hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 2.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in existing conduit, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch.complete all as specified and directed by Emgr-in-Charge. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 7.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 7.00 here-in-before but point wiring for One light point controlled by two, two way switch complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 7.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in casing & caping, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
All as per ser items No. 12.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 12.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the same board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 12.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
S & F in replacement of modular Switch 16 Amp, 1 Module, single pole one way, ISI marked complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular Switch 2 way 6 / 10 A, 1 Module complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular fan regulator step type, 120W 2 Module complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, 240 Volts complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified and directed by Engr-in-Charge. Note : 1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit suitable size, complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified and directed by Engr-in-Charge. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
Material and labour in replacement of Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified and directed by Engr-in-Charge. Note : 1. The two run of 2.5 Sqmm wire, one run of 2.5 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
Supply and fix in repair Electric bell, Ding-Dong type, AC 230 Volts, Single Phase complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Modular AC Box with MCB (25A, SP) Protected Socket, with sheet steel enclosure including Top Pin of 25 A, with indicator complete all as specified and directed by Engr-in-Charge.
S & F in replacement of surface / wall mounted LED batten 20 W, luminaire made up of Extruded Aluminium Housing with PC diffuser, IP40. The LEDs used should have a colour consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 110 lumen/watt, 50,000 burning hrs, PF ≥0.95. The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed by Engr-in-Charge.
S & F in replacement ceiling recessed mounting LED luminaire, 600 mm x 600 mm, (2' x2') 35/36 watt, luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting in office areas. The LEDs used should have a color consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 110 lumen/watt, 50,000 burning hrs, PF ≥0.95, Surge Protection 3.5KV. The brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make/manufacturer as that of LED luminaires complete all as specified and directed by Engr-in-Charge.
S & F in replacement Surface mounted LED Round light fitting 18 watt, Luminaire made up of Pressure die cast Aluminum Housing with PC diffuser, IP20 from dust. The LEDs used should have a color consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 110 lumen / watt, 50,000 burning hrsPF ≥0.95, surge protection of min 2.5KV. The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed by Engr-in-Charge.
S & F in replacement Surface Spotlight with aluminum structure, with adjustable light engine to achieve the desired illumination angle of 7 watt, with high efficient LEDs and glare free including fixing accessories (CCT- 3000K), PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S & F in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base including fixing accessories complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of energy efficient wall mounted LED bulk head light fitting 10 / 12 watt, Outdoor IP65 LED Bulkhead Light, CW 6500K , PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Building security light 18 / 20 W, day light Sensor Street Light, energy efficient, should stays on as long as motion is detected, then dims to 20% if no movement is detected for 90 seconds, inbuilt day light sensor, suitable for indoors / outdoors with high efficient high power LED enclosed with toughened glass and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Plug Top 16 A, 3 Pin Plug With Indicator, glossy finish (crabtree), Poly Carbonate, Fire Retardandant, UV stabilized, complete all as specified and directed by Engr-in-Charge.
S & F in repair LED light fitting wall / roof mounted, 22 watt, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, lumen output should not be less than 110 lumens per watt, 6000K, Complete all as specified and directed by Engr-in-Charge.
S & F in repair LED light fitting wall / roof mounted, 20 watt, Inverter LED batten with square profile, Lithium Ion battery with charging time 8 hrs-10 hrs and back up time upto 4 hrs, with driver complete suitable body robust, corrosion resistant, superior finish and the system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90, lumen output should not be less than 100 lumens per watt, input voltage range 140-280 V AC, 6000K, complete all as specified and directed by Engr-in-Charge.
S & F in replacement of ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong / Grid ceiling 2' x2' Panel, of 42 watt (CW) including fixing accessories, (CCT- 5700K), PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-charge.
S & F in replacement Vanity Lights 15W , Lighting Fixtures Black Modern Bathroom / Bedroom Wall Lighting for Mirror (Warm White), High transmittance with acrylic cover, should give perfect spotlight for makeup, shave, read or display products, back painted iron body with acrylic plating surface is durable, safe and easy to clean, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-charge.
S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete with driver and lamp as specified and directed by Engr-in-charge.
S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete with driver and lamp as specified and directed by Engr-in-charge.
S & F in repairs MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB, SPN, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB, TPN, 63 Amps, 415V 10KA 'B' curve with overload and short circuit protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to relevant IS, twin core, 0.50 sqmm size complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 47.00 here-in-before but twin core, 0.75 sqmm complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 47.00 here-in-before but twin core, 1.00 sqmm complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 47.00 here-in-before but 3 core, 2.5 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement comfort bed light fitting for patient bed for Hospitals in extruded aluminium housing with PMMA diffuser having system Wattage of 31 Watts (CCT-5700) having three lights and having personalised bidirectional up & down light for pleasant and smoothing light experience including 03 Nos switches for each light complete all as specified and directed by Engr-in-Charge.
S & F in replacement Auto Day / Night on and Off Photocell LDR Sensor, Water Proof Switch for outdoor Lighting Smart Sensor Light complete all as specified and directed by Engr-in-Charge.
M&L in replacement non metallic rigid PVC conduit pipe medium grade 20 mm dia including accessories likes as tees, bends, elbows, reducers, bell mouth, tubeends, saddles, pipe hooks etc complete all as specified & directed by Engr-in-Charge.
D K ENTERPRISES (BID ID -3267203)
Ruchi enterprises (BID ID -3267307)
RUCHIKA ENGG.WORKS (BID ID -3267467)
ACR ENTERPRISES (BID ID -3271752)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .