Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹29.8 L+₹6.1 L (25.9%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Nov 2021, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
REPAIRS TO COMPOUND WALL, FENCING, PATHWAY AND HARDSTANDING, SEWAGE LINES, SEPTIC TANKS ETC. INCLUDING CLEANING IN VIMAN NAGAR AND CHANDAN NAGAR FOR SMQS AND OTMS UNDER AGE BR-II OF GE (AF) LOHEGAON AT AIRFORCE STATION PUNE
2021_MES_485285_1
8523/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹70,000
Yes
15 Jan 2022
30 Oct 2021
1 Dec 2021
30 Oct 2021
24 Nov 2021
12 Nov 2021
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in soft/loose of soil complete all as specified and directed.
M&L 150mm dia RCC drain pipes class NP2 laid in treches & jointed for 150mm dia pipe in loose joints etc complete all as specified and directed.
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 150mm Dia complete all as specified and directed. ( Note : Work in Foule Position )
M & L PVC (SWR) branch piece, for 75mm bore single (single Y) equal or unequal complete all as specified and directed.
M & L PVC (SWR) branch piece, for 110mm bore single (single Y) equal or unequal complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm in soft loose soils complete all as specified and directed.
Removing the excavated surplus soils not exceeding 50mtr but N.exc 250 mtr and depositings where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for Concrete bed to drain pipes 1:4:8 including packing under, and haunching against the sides of pipes after they are laid and tested (dia-150 mm) complete all as specified and directed.
Demolition and breaking up drain pipes including fittings AC or CI set in cement mortar of 100mm bore complete all as specified and directed.
Ditto all as per Ser Item No 9.00 above but 75 mm Bore complete all as specified and directed.
M & L PVC (SWR) pipes 110mm single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed.
M & L PVC (SWR) pipes 75 mm singlesocketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type flushing cistern 10 ltrs capacity, low level , white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Demolition of RCC manholes covers of any description and in any position complete all as specified and directed.
M&L RCC precast (1:2:4) type B1 using 20 mm graded stone aggregate in Manholes covers set in CM 1:4 complete all as specified and directed.
M&L deformed bar unto 10mm dia reinforcement incl cutting , bending and binding with mild steel wire ennealed not less than 0. 90mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius bends plain 110 mm bore complete all as specified and directed.
Ditto all per Ser Item No 17.00 above but bends plain 75mm bore complete all as specified and directed.
S&F cast iron floor trap with grating incl joining to waste pipe of outlet 100mm dia complete all as specified and directed.
S&F PVC gully traps, square 125X110 size fixed in repairs complete all as specified and directed.
Cleaning of blockage of WC ( Indian ) type complete all as specified and directed.
Cleaning of blockage of EWC ( western ) type complete all as specified and directed.
Cleaning of blockage of manhole of any size of kitchen, WC, bathrooms, urinal etc by manually or machinically including flusing with water throughly and removing the waste material for the following depth of manhole not exceeding 1.0m complete all as specified and directed.
Ditto all as per Ser Item No 23.00 above but depth exceeding 1.0 m but not exceeding 2.0 m complete all as specified and directed.
Ditto all as per Ser Item No 23.00 above but depth exceeding 2.0 m complete all as specified and directed.
Dewatering complete from sokage well, by pumping, through tanks and removed out side of MD Land etc complete all as specified and directed.
Cleaning and rodding the blocked sewage line to any depth till the smooth flow of sewage line is restored including plugging of manholes tempoarily as and when required and washing down complete sewage line with water including removing sludge, and foreign materials from manholes in line and removing and refixing manhole covers and rodding complete all as specified and directed for 100 mm bore dia of pipe.
Ditto all as per Ser Item No 27.00 above but 150 mm bore complete all as specified and directed.
Ditto all as per Ser Item No 27.00 above but 200 mm bore complete all as specified and directed.
Scooping & taking out sludge,sullage and foreign materials from septic tank, of any description and depth including removing and refixing of vocersand appliances required for safe disposal of sludge and foreign materials either by carrying the same in covered trolly outside defence land and it should be disposed off at such place which is not determinated to public health complete all as specified and directed.
Cleaning of gully traps of any size including blokage & complete all as specified and directed.
Surface dressing n.exc 15cm deep including cleaning away grass vegetation saplings shrubs , bush wood, undfgrowth roots and trees not exc 30cm girth including diwposal of spoils , in any type of soil complete all as specified and directed.
Demolition of brickwork or stone masonary built in cement mortar complete all as specified and directed.
M&L PCC solid block masonry 1:3:6 built in Cement mortor 1:6 complete all as specified and directed.
M&L rendering 15mm thick in cm 1:4 on fair faces of brick work or concrete surface in external surfaces complete all as specified and directed.
M&L for preparation of old plastered wall surface of any description washing rubbing and stopping of distembered and painted surfaces and applyIng two coat of cement based paint complete all as specified and as directed.
M&L PCC 1:2:4 type B1 using 20mm graded aggregate as in surface channels including benching in manhole bottoms complete all as specified and directed.
Disconecting existing tanks of 500ltrs, setting a side (or lowering if required) for repairs, cleaning etc and hosting if required reconecting and refixing in position complete all as specified and directed.
Disconecting existing tanks of 1000ltrs, setting a side (or lowering if required) for repairs, cleaning etc and hosting if required reconecting and refixing in position complete all as specified and directed.
S&F in repairs 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with close top) hoisted and fixed in position after dismantling water tank and removing to store complete all as specified and directed.
S&F 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with close top) hoisted and fixed in position complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
M & L for Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc.conforming to FE 290 Gde E165 etc complete all as specified and directed.
S & F Mild steel screw bolts 11 to 15mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M & L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out hard soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M& L for PCC 1:4:8 D2 75mm thick complete all as specified and directed.
M & L for coloured heavy duty Chequered tiles 30cm x 30cm x 25mm thick,coloured rubber moulded set, jointed and pointed in neat cement slurry in floors complete all as specified and directed.
M& L 50 mm sand cushioning for laying paver block complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block 65 mm thick rubber molded any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment over sand complete all as specified and directed.
S& F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed.
S&F Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe- 290 Gde-E-165 complete all as specified and directed.
Dismantling floor hearth or wall tiling incl CM bedding (but not backing) removing serviceable tiles to store and rubbish on the premises complete all as specified and directed.
M&L Glazed Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over rendering 10mm thick in CM (1:4) , for dado/skirting tiles complete all as specified and directed.
M&L for 7mm thick non skid coloured ceramic tiles (area of each tile exc 0.06 and nexc 0.11sqm) etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments laid on screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and directed.
S& F in repairs Wash down water closet (Pedestal pattern), complete all as specified and directed.
S&F in repairs Water closet (Squatt pattern) complete including provision of lime concrete bedding complete all as specified and directed
S & F in repairs Bib taps, cast copper alloy Chromium plated 15 mm bore long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repairs Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S & F in repairs PVC Connection 15mm size and 450mm long complete all as specified and directed.
S&F in repairs 15 mm dia stop cock of cast copper alloy but fancy type chromium plated screwed down high presser with crutch or butter fly handle on both ends for iron pipe or for union fixed complete all as specified and directed.
R K ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .