| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC NO 1 KAMAM STREET SELAIYUR CHENNAI 600073 | CHENNAI | CHENNAI | TAMIL NADU | 600073 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.2 L+₹4.0 L (17.0%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹33.5 L+₹10.3 L (44.2%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | rc enterprises L3 | Vishwa Enterprises L1 | SJM CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully Existing old conventional ceiling fan including BLDC fan/exhaust fan/wall Mounted fan/pedestal/Air circulator fan of any size/ Make after disconnecting the electrical connection etc and transporting, depositing safely wherever directed complete all as specified and directed by Engineer-in-Charge. | 340 | Each | 10 ₹3,400 Lowest | 70 ₹23,800 | 20 ₹6,800 |
| 2.00 | Refixing/Installing only ceiling fan of any type,size,make after replacing the old unserviceable spares such as carter pin, rusted nut bolts,split pin, rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, etc and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge.
Note:- (i) Rewinding wires,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured and paid seperately under relevent items.. (ii) The Refixing fan shall be tested after fixing the blades and issues if any, shall be rectified by the contractor and cost of the same shall deemed to be inclusive in this quoted rate. | 100 | Each | 75 ₹7,500 | 70 ₹7,000 | 50 ₹5,000 Lowest |
| 3.00 | Refixing /Installing only Exhaust/Pedestal/Wall Mounted/aircirculator fans along with louvers any description any make, replacing the old unserviceable spares such as carter pin, rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge.
Note:- (i) Rewinding wires,spare parts such as ball bearing, capacitor,bush etc required to make the fan serviceable shall be measured and paid seperately under relevent items.. (ii) The Refixing fan shall be tested after fixing the blades and issues if any, shall be rectified by the contractor and cost of the same shall deemed to be inclusive in this quoted rate. | 240 | Each | 75 ₹18,000 | 70 ₹16,800 | 50 ₹12,000 Lowest |
| 4.00 | Material and labour for rewinding of fan motor by skilled technician with new super enameled copper winding wire of same gauge, specification and weight as prescribed by OEM/Manufacturer through standard engineering practice, after cutting and removing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials for the exhaust fan225 to 300 mm Sweep complete all as specified and directed by Engineer-in-Charge. | 75 | Each | 600 ₹45,000 | 450 ₹33,750 | 400 ₹30,000 Lowest |
| 5.00 | All as per item No.04 but exhaust Fan 350 to 450mm Sweep | 50 | Each | 600 ₹30,000 | 450 ₹22,500 Lowest | 650 ₹32,500 |
| 6.00 | All as per item No.04 but Pedestal fan 400mm to 600mm sweep | 25 | Each | 600 ₹15,000 Lowest | 800 ₹20,000 | 850 ₹21,250 |
| 7.00 | All as per item No.04 but wall mounted fan 400mm sweep | 55 | Each | 600 ₹33,000 | 200 ₹11,000 Lowest | 450 ₹24,750 |
| 8.00 | All as per item No.04 but ceiling fan of 1200 mm sweep | 50 | Each | 600 ₹30,000 | 250 ₹12,500 Lowest | 500 ₹25,000 |
| 9.00 | All as per item No.04 but ceiling fan of 1400 mm sweep | 50 | Each | 600 ₹30,000 | 200 ₹10,000 Lowest | 600 ₹30,000 |
| 10.00 | All as per item No.04 but air circulator fan of 450 to 600 mm sweep | 35 | Each | 600 ₹21,000 | 450 ₹15,750 Lowest | 1,000 ₹35,000 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
2 Aug 2025, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIR MAINT TO EARTHING LIGHTENING ARRESTORS AIR COMPRESSOR AND MAINT OF EARTH VALVE OF TECH BLDGS AND MAIN CAMPS AREA AND REPAIR MAINTENANCE TO INTERNAL ELECTRIFICATION INCLUDING FANS GEYSERS SOLAR WATER HEATER AT MAIN CAMP AT AFS TAMBARAM
2025_MES_718808_1
GE(AF)/TBM/8818/E8
Open Tender
Civil Works
Item Rate
270 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹78,000
Yes
3 Sept 2025
5 Jul 2025
4 Aug 2025
5 Jul 2025
2 Aug 2025
19 Jul 2025
Amount
Taking down carefully Existing old conventional ceiling fan including BLDC fan/exhaust fan/wall Mounted fan/pedestal/Air circulator fan of any size/ Make after disconnecting the electrical connection etc and transporting, depositing safely wherever directed complete all as specified and directed by Engineer-in-Charge.
Refixing/Installing only ceiling fan of any type,size,make after replacing the old unserviceable spares such as carter pin, rusted nut bolts,split pin, rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, etc and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge. Note:- (i) Rewinding wires,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured and paid seperately under relevent items.. (ii) The Refixing fan shall be tested after fixing the blades and issues if any, shall be rectified by the contractor and cost of the same shall deemed to be inclusive in this quoted rate.
Refixing /Installing only Exhaust/Pedestal/Wall Mounted/aircirculator fans along with louvers any description any make, replacing the old unserviceable spares such as carter pin, rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge. Note:- (i) Rewinding wires,spare parts such as ball bearing, capacitor,bush etc required to make the fan serviceable shall be measured and paid seperately under relevent items.. (ii) The Refixing fan shall be tested after fixing the blades and issues if any, shall be rectified by the contractor and cost of the same shall deemed to be inclusive in this quoted rate.
Material and labour for rewinding of fan motor by skilled technician with new super enameled copper winding wire of same gauge, specification and weight as prescribed by OEM/Manufacturer through standard engineering practice, after cutting and removing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials for the exhaust fan225 to 300 mm Sweep complete all as specified and directed by Engineer-in-Charge.
All as per item No.04 but exhaust Fan 350 to 450mm Sweep
All as per item No.04 but Pedestal fan 400mm to 600mm sweep
All as per item No.04 but wall mounted fan 400mm sweep
All as per item No.04 but ceiling fan of 1200 mm sweep
All as per item No.04 but ceiling fan of 1400 mm sweep
All as per item No.04 but air circulator fan of 450 to 600 mm sweep
Supply only ball bearing size (6201/6202/6203) suitable for ceiling fans size 1200/1400 mm Sweep complete all as specified and as directed by Engineer-in-Charge.
Supply only ball bearing Size (2001/2002/2003) suitable for exhaust/wallfan/pedestal fan of any size and make complete all as specified and as directed by Engineer-in-Charge.
supply only capacitor of capacity 2.5 mfd for the fans in position complete all as specified and as directed by Engineer-in-Charge.
supply only capcaitor of capacity 4 mfd for the fans in position complete all as specified and as directed by Engineer-in-Charge.
supply only GM bush suitable for ceiling fan of size 1200/1400 mm Sweep complete all as specified and as directed by Engineer-in-Charge.
supply only bush suitable for exhaust fans any make/size complete all as specified and as directed by Engineer-in-Charge.
supply only PCB board of BLDC ceiling fan convertible 240 Volt AC to 12 Volt DC suitable for any type/model ceiling fan 1200 mm sweep 230 Volt 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Material & labour for Cleaning and preparing the surface of ceiling fan of any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat synthetic enamel paint painting over ceiling fan alongwith down rod upto 2.00m long with two coats of synthetic enamel white paint of approved colour by spraying including preparation of old painted surface & writing of MES No on the fan complete all as specified and as directed by Engineer-in-Charge.
Material & labour for Cleaning and preparing the surface of exhaust /wall mounted /pedestal/Air circulated any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat of synthetic enamel paint of approved colour by using spraying machine including writing of MES No in appropriate format and size on the fan complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully storage type water heater (Geyser) upto 25 /50 Ltrs capacity of any type, make after disconnecting all electrical connection,descaling the inner container heating element base assembly etc by using diluted hydrochloric acid and cleanning thoroughly,filling the inner container with water and checking for leakage if any reassembling the geyser after locking for leakage by bracing and refixing the electric and water supply lines,finally refixing and testing on completion,complete all as specified and as directed by Engineer-in-Charge. Note:-spares shall be measured and paid saperately under relevent items of this Schedule as "Supply only"
Supply only Heating Elements with rubber gasket thread/push type 230V,2.0/1.5 KW complete all as specified and as directed by Engineer-in-Charge. Make:-Bajaj/Usha/Racold
Supply only Thermostart suitable for Geysers 25 to 50 liters capacity,and temp range 30 to 80 degree centigrade and cut off at 70 degree centigrade complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair flexible 4sqmm, 3 core wire ,230 V , complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement 3 pin industrial plug top for geyser, 16 amp,230 volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair PVC Connection pipe 15 mm dia 450 mm long heavy duty suitable for hot/cold water with two brass union and washers complete all as specified and as directed by Engineer-in-Charge.
Material and labour for servicing the solar water heater any make/type/capacity,cleanning/descaling of solar collecting panel of copper pins/tubes including replaceing the sacrifical anode rod and panel tuffen glass 4 mm thick (size2mx1m) complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully Air Curtain fan size 3 feet , 230 Volt 50 Hz any size/make for repair/replacing the winding, nut bolts,bearing washers,bush,PVC clamps for holdings of capacitor, etc and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor cable complete all as specified and as directed by Engineer-in-Charge. Note:- Rewinding wire and spare parts such as ball bearing, capacitor,bush etc required to make unit serviceable and refixing the air curtains with all above said items are inclusive of the quoted rate.
Supply and fix in repair ceiling fan down rod size of 15 mm dia GI pipe medium grade duly cutting/threading /drilling etc.suitable for check nuts and split pin including 'U' clamp bolts,nuts,washers,rubber split pin check nuts etc suitable for ceiling fan 1200 mm sweep including taking down of unserviceable complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair ceiling fan clamp/ hook made out of MS flat iron 40x6 mm bent to shape fixing to 50 mm GI pipe for hanging ceiling fan incl taking down unserviceable complete all as specified.
supply and fix in repair ceiling fan regulator electronic type with control suitable for 1200/1400 mm ceiling fan all as specified and as directed by Engineer -in- charge.
M&L for sub main wiring with 2 runs of 4 Sqmm single core FRLS PVC insulated unsheated cable 1100 volts grade with multistranded copper conductor drawn through in existing surface/recessed steel/ PVC conduit and accessories on surface of wall roof etc with one run of 4.0 sqmm of PVC FRLS copper cable for earth continuity including dismantling of old existing unserviceable sub main wiring and making good disturbed portion complete all as specified and as directed by Engineer -in- charge.
All as per item No 31 here in befire but with 2x6.0 sqmm along with 1x6.0 sqmm as earth continuty conductor complete all as specified and as directed by Engineer-in-Charge.
All as per item No 31 here in befire but with 2x10.0 sqmm along with 1x10.0 sqmm as earth continuty conductor complete all as specified and as directed by Engineer-in-Charge.
supply and fix in replacement MCB Single Pole 6 to 32amps,10KA 240 volts,50 Hz.all as specified and as directed by engineer-in Charge.
Supply anf fix in replacement Single pole and Neutral Encloser with two pin and earth plug and Metal glad Socket Complete with one Single Pole MCB 20/32 Amps 240Volt complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) and making good of the disturbed surface of wall, floors etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls/ suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxes concealed/surface in wall with 3 mm thick hylam sheet or suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following :-
All as per Item No 37 above for One fan point controlled by one 5 Amps switch complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 37 above but for One 3 pin 5 Amps socket outlet on same board complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 37 above but for One 3 pin 5 Amps socket outlet on independent board complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Modular switch 1 way 6A, 1 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Modular switch 1 way 16A, 1 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Modular socket 6A 3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Modular socket 6A/16A 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Modular Fan regulator 120 W 2 Module suitable for 1200mm/1400mm sweep fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Switch piano flush type 5 Amps ,Single pole one way complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Switch socket flush type 2 in 1, 3 pin 5 / 15 Amps 240 V complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Fan regulator stepped type electronic flush/switch type, suitable for 1200mm /1400 mm sweep fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement PVC ceiling rose two to three terminal plate and jumbo type complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable ceiling fan and depositing the same to MES Store yard for BER process and Supply and fixing new five star rated with brushless direct current motor (BLDC) ceiling fans 1200 mm sweep complete with blades, down rods and accessories, 230 V including writing MES No in appropriate format as directed complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable wall mounted fan and handing over to MES Store yard for BER process and Supply and fixing new wall mounted fan 300 mm sweep including writing MES No in appropriate format as directed complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable exhaust fan and handing over to MES Store yard for BER process and Supply and fixing new exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including writing MES No in appropriate format as directed complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable exhaust fan and handing over to MES Store yard for BER process and Supply and fixing new exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including writing MES No in appropriate format as directed complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable earthing of any type and description ,Material and labour for earthing complete with copper earth plate electrode 600mmx600mmx3mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 20mmx3 mm copper strip by means of bolts, nuts, washers of galvanized including GI protection pipe 40mm dia, light grade, all as shown in electrical plate No.3 of SSR Part-I SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1cover slab 50mm thick with 8mm CTD bar 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable earthing of any type and description Material and labour for earthing complete with GI plate electrode 600mmx600mmx6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 32mm x 6 mm GI strip by means of bolts, nuts, washers of galvanized including GI protection pipe 40mm dia, light grade, all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1cover slab 50mm thick with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grad e pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable earthing of any type and description .Material and labour for earthing complete with GI plate electrode 600mmx600mmx6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to GI earth wire 4.0 mm by means of bolts, nuts, washers of galvanized including GI protection pipe 15mm dia, light grade, all as shown in electrical plate No.3 of SSR Part-I SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair and replacement of Copper strip of size 20mm x 3.15mm with saddles/insulaters and fixing screw etc for roof conductors and down conductors above ground complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs and replacement of GI wire 4.0mm dia as a earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for inter connecting of earth electrodes complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs and replacement of aluminium strip of size 25mm x 3.15 mm with saddles/insulaters and fixing screws for roof conductors and down conductors above ground complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair and replacement of test point terminal block made of gun metal or phosphorus bronze size 75mmx 75mm x 25mm, drilled and screwed including 3 Nos 8mm dia , 25mm long hex head screw and hologen free weather proof IP65 enclosure of size not less than ( 119x139x70) with one / two brakets nad screws complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair and replacement of air termination single pointed copper rod 12mm dia and 300mm long fixed on copper strip complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair and replacement of air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair and replacement of GI tubing 40mm bore 'Medium grade' for protection of earth continuty conductor fixed on wall/laid under roads crossing etc including making good the disturbed surface complete all as specified and as directed by Engineer-in-Charge.
Taking out the existing earth chamber with cover carefully , cleaning the surface of the earth pit inside and outside ,including providing charcoal and salt mixed with water pouring into earth pits as required at site , removing the old rusted nuts , bolts with new nuts and bolts, testing of earth value with necessary earth testing equipment and writing the earth value on top of the cover with white colour synthetic enamel on black colour back ground and refixing the earth chamber in position complete all as specified and as directed by Engineer-in-Charge. Note :- Earth testing equipment shall be brought by the contractor for testing of earth valve.
M&L for testing of earth value with necessary earth testing equipments and writing the earth value on top of the cover with white colour synthetic enamel on black colour back ground complete all as specified and as directed by Engineer-in-Charge. Note :- Earth testing equipment shall be brought by the contractor for testing of earth valve. Test report shall be submitted to Engr- In -Charge
M&L for PCC 1:3:6 type C1 solid block masonry chamber with RCC 1:2:4 type B1 cover slab 50mm thick reinforced with 8mm CTD bar 100mm centre to centre on bothways, internal plaster with CM 1:4 15mm thick with suitable mild steel handle including necessary earth work excavation and taking out existing un serviceable earth chamber complete all as specified and as directed by Engineer-in-Charge.
Material and labour in replacement for maintenance free earthing electrode of low carbon steel rod, UL listed of 25mm dia, 3 mtr long, coated with copper of 254 microns thickness, CPRI tested for short time current withstand test of 20 KA, coasting thickness . Environmental test (salt mist test ), Bend test,Tensile strength , yeild /ratio ,electical resistivity test,complete with clamps and 2 bags of high grade earthimg compund IEC 62561-7 complete eco friendly , maintenence free,anti corrosive lead-free ,super conductive ,mineral based high grade earthing compound,to enhance soil conductivity.with resistence less than 0.20 ohms-meters, should be leach proof and sulphur free complete with earth inspection champer of dimension :width :320mm x 320mm , Height : 192 mm Weight :30 kgs, Load bearing capacity :5000 kgs Including drilling of bore in any kind of soil complete all as specified and as directed by Engineer-in-Charge. Note : THE RATE DEEMED INCLUSIVE OF SOIL RESISTIVITY TEST, AS PER SOIL RESISTIVITY TEST NO OF EARTH PITS TO BE DECIDE. i) Earth resistance value shall be less than 0.5 ohms ii) Copper strip 2x 3 mm for interconnection of earth pit (Brazing and copper bolt and nuts) shall be paid separtely under relavent item.
Material and labour for 50 sqmm single core multistranded copper wire ,1100V, AC including suitable PVC pipe for fixing on wall / ceiling / beams etc with saddles and terminating the cable end with suitable copper lugs complete all as specified and as directed by Engineer-in-Charge.
Material and labour for GI pipe 25 mm light grade with all fitting laid in trenches complete all as specified and as directed by Engineer-in-Charge.
Annual Maintance contract for a Air compressor model EG90-9,415 V 50HZ, motor capacity 90 Kw ,Capacity 15.23 sqm /Min with rated pressure 8.0 Bar, Refrigerator air dryer Model No ELRD-750A working pressure 16kg/ Sq cm , capacity 750 CFM.and air tank model VA001203000L 10ASME 2062 (Make:- ELGI)(a) Check and ensure the oil level and quality of oil. (b) Check and ensure there is no air and oil leakage in the compressor package.(c) Check,clean and change the air filter (d) Check oil and oil filter at recommended intervals (e) Check and replace oil seperators element at recommended intertval.(f) Check and ensure the operation of the safety valve against the set pressure.(g) Check and ensure all the quick coupling fittings and flexible hoses are intact.(h) Check and ensure the proper fuctioning of all valves in the compressor package and replace the service kits.(j) Check and clean the oil and after coolers interally if required.(k) Check and ensure the proper fuctioning of the auto drain valve and clean/ change as required.(l) check and ensure the proper fuctioning of all the satey switches.(m) Check and ensure the proper functioning and condition of electrical contrators. (n) Check and ensure the proper fuctioning of all safety interlocking devices.(o) Conduct diagnostic testing of the controller.(p) Check the compressor operating enviroment and recommended revalant corrective action for reliable operation of the compressor.(q) Study and recommend upgrade kits.(r) Submit the compressor Performance /Health Checks report . Note :Servicing/Repairing of Air compressor specified above shall be carried out through OEM /reputed authorised service Engineer.
supply only Oil Filter element -75(Make:- ELGI Cart Part No :-B004800770001)
supply only ELGI Air lube syn-plus oil (Make ELGI Cart Part No :-0009981024)
supply only service kit for HDKG120(Make ELGI Cart Part No :-B009401070002)
supply only Grease EMUNIREXN3(Make ELGI Cart Part No :-015404151)
supply only Service kit for VVF15 BDV No (Make ELGI Cart Part No :-B009401070003)
supply onlySolenoid valve NC,24V 50 Hz (Make ELGI Cart Part No :-B007300990004)
supply only Auto drain valve -F3 (Make ELGI Cart Part No :-B000306040013)
supply only DRIVE COUPLING INSERT UCW276(Make ELGI Cart Part No :-B005401170005)
supply only SINGLE ACTING ACTUATOR HOERBIG(Make ELGI Cart Part No :-B0115010700001)
supply only FILTER ELEMENT F5(Make ELGI Cart Part No :-B004700770029)
supply only AIR OIL SEPERATOR 90-110KW(Make ELGI Cart Part No :-B006700770023)
supply only PREFILTER 90-160KW(Make ELGI Cart Part No :-B000606160001)
Supply only THERMAL ELEMENT 80 DEG CELCIUS(Make ELGI Cart Part No :-B008706030009)
Supply only MPV WITH CHECK VALVE -MPVL65(Make ELGI Cart Part No :-B009301070003)
supply only MJ81BK(110-240VAC),GIS Make :-(Make ELGI Cart Part No :-018362741)
Supply only NON Return Valve 1/8 "(Make ELGI Cart Part No :-B004100170001)
Material and labour MS pipe 15mm to 20 mm complete.
SJM CONSTRUCTIONS (BID ID -3380492)
rc enterprises (BID ID -3372424)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .