| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-Finance 114 4 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | ₹1.6 L | L1 | Accepted-Finance Lowest |
| 2 | L2₹1.6 LRejected-Finance 28 DOCTOR LANE | ₹1.6 L | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹1.6 LRejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹1.6 L | L3 | Rejected-Finance 3rd Lowest |
| 4 | L4₹1.6 LRejected-Finance 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | ₹1.6 L | L4 | Rejected-Finance 4th Lowest |
| 5 | L4₹1.6 LRejected-Finance CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | ₹1.6 L | L4 | Rejected-Finance 4th Lowest |
Tender Value
₹1.6 L
EMD Value
₹3,228
Closing Date
6 Feb 2026, 12:00 pmClosed
AEWBESDPWD
Block I Ground Floor Writers Buildings Kolkata 700001
Dismantling reinstallations of existing electrical installation for Bankshall court Building No II due to replacement of Damage wooden Floor slab in 7th MM court, 8th MM Court and police prosecutor south room with new RCC slabs under WBESD,PWD.
2026_WBPWD_991468_1
WBPWD/AE/WBESD/eNIT-33 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
15 days
Bankshall Court
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,228
3 Jun 2026
20 Jan 2026
9 Feb 2026
21 Jan 2026
6 Feb 2026
28 Jan 2026
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 3 no. suitable size “Ph , N & E” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run: 12 Mtr.
Supply & Fixing 240 V, 1 nos. 16 A, 5 pin Modular type plug socket with 1 nos. 16A Modular type switch & 3 nos. 6 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch (Brand approved by EIC), and Indicator without plug top on 2 row 16 Module GI Modular type switch board with 2 row 16 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. Make (Legrand myrius/Schneider/ABB)(incl necy. blank plates)
Supply & Fixing 240 V, 2 nos 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. onnections with PVC Cu wire and earth continuity wire etcMake (Legrand myrius/Schneider/ABB)
S & delivery of single/Twin LED fittings with all accessories including supply of LED lamp lamps and all accessories(make: Philips//GE/Wipro as per choice of EIC)
single fittings (cat No.- TMC-501P 1xT-LED 22W P3242, make Philips) with 1nos 4ft AC 230V,18 W, 110Lm/W Polycarbonate LED Tube
Twin fittings (cat No.- TMC-501P 2xT-LED 22W P3242, make Philips) with lamp 2nos 4ft AC 230V,18 W, 110Lm/W Polycarbonate LED Tube
S & delivery of 240V,90W, minimum rpm 1325rpm, 3-blades, AC Full body metal wall bracket fan (motor housing canopy should be metalic and inbuild thermostate protection )450 mm or 18 inch . (Make orient, Model :- Crompton Storm 2 plus /Orient/EPC as per choice of EIC)
Supplying & Delivery 48" (1200mm) minimum ISI 1 star rated AC ceiling fan complete with safty rope, and P2 type capacitor down rod, canopy fork, blades etc. but without regulator. (Crompton/Orient/USHA striker as per choice of EIC)
Fixing only Wall fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Dismantle all existing electrical items mentioned below by a skilled electrician in preparation for replacing the damaged wooden roof slab with an RCC roof slab by the civil department. Pack all dismantled materials in suitably sized cartons and reinstallation this dismental items at the same location after civil renovation work as per direction of EIC
Point wiring
Single/Twin tube light fittings with down rod and clamp
AC timer switch with wiring
Ceiling Fan with down rod and fan clamps
Wall Fan with all Accessories
Computer board with wiring
Dismantling of switch board other than point wiring and computer board like power plug and IT power line along with wiring.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.57 MB
BOQ_2424083.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid