Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC 39 W 1 ASHOK VIHAR SAKET NAGAR KANPUR 208014 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208014 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹37.2 L+₹2.7 L (7.94%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹37.2 L+₹2.7 L (7.97%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹37.8 L+₹3.4 L (9.77%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹38.4 L+₹4.0 L (11.5%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹40 L
EMD Value
₹40,000
Closing Date
17 Oct 2022, 6:00 pmClosed
Maj Srinath P L
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/ REPLACEMENT OF ROOF SHEETING , FALSE CEILING, WALL PANELLING, WPT, PLASTERING ETC. AT DGQA AREA KANPUR OF AGE B/R-I UNDER GE(I) KANPUR
2022_MES_554737_1
GE(I)/KAN/T-65 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹40,000
Yes
5 Dec 2022
27 Sept 2022
24 Oct 2022
27 Sept 2022
17 Oct 2022
10 Oct 2022
Amount
Demolition of brickwork or including all quoins, arches, pillars, etc, bilt in cement mortar complete all as specified and directed.
M & L of Brickwork with fly ash bricks, old size straight or curvedon plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per item no. 2 here in before but except bricks and complete all as specified and diredted.
Dismantiling of AC sheet (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Fixing only old 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J-type or cranked hook bolts.
Dismantling structural steel work including doors, gates wind ties etc but excluding framed truss etc complete all as specified
S &F of Mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging also fastening and fixing complete for Fe-410- W(Gde- E-250) quality-B
S&F of 1.00mnm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Taking down cement plaster on bricks or concrete surfaces including raking out joints for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1 : 6 by using on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on surfaces other than fair face of brick work of walls, finished fair & even and complete all as specified and diredted.
M & L for applying three coat white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of primer coat of approved shade on walls and complete all as specified and diredted.
S & F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
All as per item no.16 above but except material and complete all as specified and diredted.
S & F 2 mm thick corrugated fibre glass reinforced translucent sheeting in roof/cladding/wall with coach screw and washer etc and complete all as specified and diredted.
Dismantiling of CGI/PGI sheets any thickness as in roof coverings complete all as specified and directed.
S & F 0.63 mm thick galvanised, corrugated mild steel sheeting with zinc coating 120 gram/sqm two corrugations side lap & 150 mm end lap ,fixed with 'L' type or 'J'type or crancked hook bolt and washers orwith self drilling zinkallum coated metal screws having cap with rubber washers complete all as specified and directed.
S & F 0.63 mm thick PGI sheeting of class -VIII as in ridges, hips, wall cladding and straight flashings etc ,fixed with 'L' type or 'J'type or crancked hook bolt and washers or with self drilling zinkallum coated metal screws having cap with rubber washers complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work complete all as specified and dorected.
S & F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed at site using Fe 410 W grade E-250 quality A.
S&F for framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolation of cement concrete in ground floors and pavings exc 15 cm but n exc 20 cm thickness (below or above ground level)
M & L 40 mm thick PCC (1:2:4 ) type B-1 using 20mm graded aggregate) as in flooring finished even and smooth without using of extra cement laying in alternate bay complete all as specified and directed.
M & L 75 mm thick PCC ( 1:3:6) type C-1 using 20mm graded aggregate in pannels as in plinth protection and joints filled (with hot bitumin VG 10 & sand,1:3) complete all as specified and directed.
Demolition of cement concrete in any position, roof above ground level and disposal of unserviceable materila, debries and disposal of rubbish outside MD land complete all as specified and directed
M&L PCC 1:2:4 Type B-0 (Using 12.50 mm graded stone aggregate) in roof, kerbs or mud stops, benching rounded or chambered angle complete all as specifed.
M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Dismantling loose concrete cover of RCC coloumns, beams slabs, chajjas and the like as diected, roughening and cleaning in concrete surfacces with steel wire brushes, washed with water and allowed to drey including derusting of steel reinforcement , providing facbric mild steel wire mesh 75mm x 75mm x 2mm dia as reinforcement to concrete surfaces, applying adhesive/admixture over steel mesh and providing 20 mm thick (average thickness) dubbing coat in CM (1:3) including 10 mm thick plastering in CM 1:4 even and smooth complete all as directed including providing scaffolding system on the exterior side, upto three storey height made with wooden balli/bamboo of suitable size or MS tube stiffened with suitable bracing, runners connection with the building, challies for making working platform upto requisite height and required location with essential safety features for the workmen etc. Complete as per direction and approval of Engr-in-Charge.
Dismantling wall panelling or ceiling boards of any descripton any thickness & at any height complete all as specified and directed.
S &F for 12mm thick Gypsum board 60x60cm in size fixed in ceiling (aluminium snap grid work) with screws as per manufacturer instructions and including applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Supply & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with DUNE (MICRO LOOK) EDGE TILES WITH ARMSTRONG XL 15 mm EXPOSED STEEL ANGLE. The tiles should have Humidity Resistance (RH) of 99%, NRC Upto 0.5, Light Reflectance >85%, Thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class 0/Class1 (BS 476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38-41%.The steel angle should be of “Armstrong” make with 15mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32,mm and a load carrying capacity of 7.5 Kgs/Sqm. The T Sections have a Galvanizing of 90 grams per Sqm & passed through 500 hrs of Salt test ,Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre incl 4 mm dia suspension wire MS @ 1200mm C/C complete all as specified and directed according to manufacturers instruction and Complete all as specified and as directed.
M & L for aluminium grid frame work for false ceiling of size 605x605mm, the snap grid shall be of aluminium main & cross tee of size 36.5x25x1.4mm (weighing 0.24 Kg/RM) and angle of size 23.5x26.4x1.4mm (weighing 0.191 Kg/RM) fixed to wall with rawl plug and stainless steel screw 50mm 450mm c/c and tied with and incl 4 mm dia suspension wire MS @ 1200mm C/C all as specified and directed
M & L for providing PVC false ceiling consisting of 600mmx 600mm ,5mm thick plain PVC sheet of density 600 kg / cbm used as a panel insert in a frame work made using anodised aluminium 'T' section of size 25mmx25mm of 19 gauge or 1 mm thick a square pattern of a grid size of 600mmx600mm . complete all as specified and directed by Engineer in charge and as per manufacture's spection .Make : Rajshri / Everest/Sintex as approved by GE (I)
Supply & Fixing in repair of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with DUNE (MICRO LOOK) EDGE TILES WITH ARMSTRONG XL,of size 600x600x16 mm complete all as specified and as directed.
S &F in repair for 12mm thick Gypsum board 60x60cm in size fixed in ceiling (aluminium snap grid work) with screws as per manufacturer instructions and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M & L Solid PVC wall lining complete consisting of 5 mm thick single side prelaminated PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame incl taking down complete all as per manufacturers specification and all as directed.
M&L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as specified and directed by Engr in Charge.
Demolition brick tiles / APP membrance by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed by the Engineer-in-charge.
M&L for PCC type B0 (1:2:4 using 12.5mm graded stone aggregate) in padding for maintaining proper slope over roof treatment finished even and fair mixed with Non shrink chemical of Make- FOSROC/SIKA/PIDILITE as per manufacture's sistructions, PCC shall be cured with curing compound fof Make - FOSROC/SIKA/PIDILITE as per manufactures. Rate of Non shrink chemical and curing compound is deemed to be included in the quoted rate.
M&L for Preparation of plastered roof surface by cleaning surface free from dust and other foreign materials etc. and laying in repair Atatic poly propylene polymer modified membrane pre fabricated 3mm thick with non woven polyester matt central core of 160 gms/Sqm weighing not less than 3.5kg per sqm laid over primer conforming to IS 3384 @ 0.4 lit/sqm by using LPG/Butane torch and applying uniform pressure with a roller with overlap of 100mm in longitudinal direction and 150mm in transverse direction laid as per manufacturers instructions complete all as specified and directed and including following courses of descriptions given below :- (a) A coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm. (b) Laying of APP modified membrane described hereinbefore with joints sealed with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and curved well before lying the membrane. (c) Applying binding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm. Note : The contractor shall give a guarantee of 10 years from the date of completion of work for sunken treatment. The amount Rs. 25.00 (Rupees Twenty five Only) per Sqm and min of Rs 2500/- for sunken treatment shall be withheld from contractor’s final bill till the expiry of guarantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE (I) Kanpur.
M&L for half mirror polish grinding and polishing of kota stone/marble etc. flooring and skirting complete all as specified and directed
S&F in repair PVC(SWR) Pipe 110 mm pipes double socketed in any length with rubber ring joints fixed to wall/ceiling and complete all as specified and diredted.
S&F in repair PVC (SWR) bends 110 mm bore and complete all as specified and diredted.
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls /ceiling or laid in floor complete.
Supplied and fixed in repair PVC (SWR) 110 mm dia junction, double ( double 'T') equal or unequal complete all as specified and directed
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and directed.
All as per item No. 50 but 20 mm dia bore pipe and complete all as specified and diredted.
S&F of 15 mm bore steel tubing, medium grade, galvanised with all fitting, fixed to walls with clips and ceiling or laid in floor/concealed complete all as specified and directed.
All as per item No. 52 but 20 mm dia and complete all as specified and diredted.
S&F of HDPE triple layer (white colour) rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable sizes and numbers including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball and incl disconnecting of old PVC water storage tank complete all as specified and directed. Make: Sintex/ Dhara/Tuff/ JS Polyplast as approved by GE.
S&F of HDPE triple layer (white colour) rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable sizes and numbers including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball and incl disconnecting of old PVC water storage tank complete all as specified and directed. Make: Sintex/ Dhara/Tuff/ JS Polyplast as approved by GE.
S&F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. Make : Prayag/Shakti
S&F in repair 20mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed.
S&F in repair 15mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed.
M&L Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in coping bedplates & other similar works, including necessary form works wearthering, slightly rounded angles and theading, complete all as specified.
M&L for repair to chajja area not exceeding 2 Sqm each including plaster in CM (1:3) or PCC (1:2:4) type B-0 using 12.5 mm stone aggregate on top with PCC benching/ haunching, repair to broken plaster with dubbing coat complete all as specified and directed. Note : Rate incl. all necessary scoffolding arrangement up to height of 12 mtr.
M&L for repair to chajja area exceeding 2 Sqm and not exceeding 4 Sqm each including dismantling of upward facia, cutting of reinforcement, plaster in CM (1:3) or PCC (1:2:4) type B-0 (using 12.5 mm stone aggregate) on top with WPC, benching/haunching, repair to broken plaster with dubbing coat complete all as specified and directed. Note : Rate incl. all necessary scoffolding arrangement up to height of 12 mtr.
Cutting and taking out grass shurbs, plants, small tree roots in building wherever periodical services to be carried out in OTM in any position and at any height (two storey building) and treated with necessary chemical/ acid to avoid for this further growth and disturbed portion making good with PCC 1:2:4 type B0 using 12.5mm graded stone aggregate and 15mm thick plastering etc in CM (1:4) finished fair and even complete all as specified and as directed. (Note : The cost of scaffolding and T&P required for repair will be deemed inclusive in this item).
M&Lfor repairing of damaged portion of mouth at terrace/roof surfaces of rain water pipe by cleaning and reparing to mouth of RWP by using CM(1:3) with mixed with liquid WPC and sealed with 85/25 hot blown grade bitumen complete to make pipe of rain rain water pipe and roof surfaces fully leak proof complete all as specified and directed
M&L cleanning of roofs by getting out growing vegetations /grass & brooming down with removing it out of MD land premises of including repairing to damaged surfaces of roof by using CM (1:3) mixed with 3% wpc & sealed with 85/25 hot blown grade bitumen complete in patch not exceeding 2.0 sqm each complete all as specified and directed
YS CONSTRUCTION
M/s S K ARORA
M/S EASTERN SUPPLIERS
RAJAT TRADERS
Lalta Prasad vijay kumar Forwarding Agency
DHARM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .