EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Supply, Installation, Testing and Commissioning of Fire detection and Alarming System at Chanchal SDH, Malda.
2024_WBPWD_741147_1
WBPWD/EE/MED/e-NIQ-25/2024-25 (2nd Call)
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
CHANCHAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹23,300
28 Mar 2025
29 Aug 2024
20 Sept 2024
29 Aug 2024
18 Sept 2024
4 Sept 2024
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel (1 Loop) with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 5" alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice.
The panel shall have in built rectifier, provision for external & internal printer (if required ), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software.. (Approval standards:VDS/ UL/ULC; (Approved Make: Honeywell / Siemens / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls / Cerberus Pro / Esser).
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 (VDS/UL/ULC approved) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.Detectors shall be UL & FM Approved.(Approved Make: Honeywell / Siemens/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls/Cerberus Pro/Esser).
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable Heat detector (VDS/ UL/ULC approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make: Honeywell / Siemens / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls / Cerberus Pro/Esser).
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS/ UL/ULC approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required.(Approved Make: Honeywell/Siemens/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls/Cerberus Pro/Esser)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 (VDS/ UL/ULC approved) approved. (Approved Make: Honeywell / Siemens / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls / Cerberus Pro / Esser).
Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Honeywell / Siemens / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls / Cerberus Pro / Esser).
Supply, Installation, Testing & Commissioning of Addressable transponder/ Monitor Modules 1inpt/ 1 output for monitoring flow switches/Fire exit doors etc complete as required. (Approved Make: Honeywell / Siemens / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls / Cerberus Pro / Esser)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab/RR Cable/Technoflex) with 20 mm NB PVC rigid conduit pipe on the surface of the wall. (Make: Precisson/Polycab/AKG-Medium).
Supply & Fixing of Motorized Fire Damper, with Microprocessor Control CP Unit, Fire BMS Link command input rail, Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI (U-555, 1995), with minimum fire rating not less than 120 min, must be Actuator Operated for Ducted type IDU. Damper Size: 1400 x 400mm (Make- Caryaire / Airmake System / Revlon) incl. Supply & Fixing of Actuator for Fire Damper and Volume Control Damper with Torque Control, CP Panel, Smoke Sensor, 340Nm Torque Motor, 230v/1ph/50hz. (Belimo/Danfoss).
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate for Fire detection and Alarm system will have to be submitted during delivery of the material. (iv) The Fire detection and Alarm system must be warranted at least for 36 months from the date of commissioning.
P R INFOSYS (BID ID -5581326)
PERFECT IMAGE SOLUTIONS (BID ID -5573274)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .