| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount | |
| 2 | L2₹21.2 L+₹59,788 (2.90%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance other than lowest. | |
| 3 | L3₹22.9 L+₹2.3 L (11.1%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance other than lowest. | |
| 4 | L4₹23.9 L+₹3.2 L (15.7%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L4 | Rejected-Finance other than lowest. |
Tender Value
₹29.5 L
EMD Value
₹59,020
Closing Date
28 Jun 2023, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
COMPREHENSIVE PREVENTIVE AND PERIODICAL MAINTENANCE OF LIFTS AT MAIN BLDG AND CTVS BLDG AT AHRR UNDER GE EM RR HOSPITALDELHI CANTT
2023_MES_599983_1
CWE/ND-15/2023-24
Open Tender
Miscellaneous Works
Item Rate
CWE NEW DELHI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M R AND R HOSPITAL
₹59,020
Yes
28 Jul 2023
31 May 2023
30 Jun 2023
31 May 2023
28 Jun 2023
14 Jun 2023
Amount
Comprehensive, preventive and periodical maintenance of lifts/elevators installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly examining, lubricating and adjusting the mechanical and electrical driving equipment, including replacement of unserviceable component such as governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, counter weight, guide rails, buffers, machines motors, generators, door ropes, UPS/ARD system, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock brake shoes, liners, contactors, relays, coils, pushbuttons, door operator VVF drive, VVVF main drive, cardoor safety device, limit switches, governor, hoistway door locks, indicators and other mechanical and electrical parts (excpet car cabin, landing door, sheave rim and Srl item No 02 to 20 of Sch 'A') for smooth functioning of elevators and incl all machine works i.e. welding, cutting, drilling, screwing, etc. as and when required, to entire satisfaction of Engineer-in-charge, including cost of materials complete including Sunday & Holiday, complete all as specified & directed for following Lift(s) / Elevator(s) -
Electric Hospital passenger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors installed at A Block lift No 02 & 03 (Make : ThyssenKrupp Elevator) -02 Nos lifts.
Electric Hospital passenger cum stretcher elevator /lifts of capacity 26 passenger serving (-1+G+4) 6 floors installed at OT (Make ThyssenKrupp Elevator) -02 Nos lifts
Electric Hospital passenger cum stretcher elevator /lifts of capacity 20 passenger serving (G+4) 5 floors installed Ramp side (Make ThyssenKrupp Elevator) -02 Nos lifts
20 passenger elevator of 1360 Kg capacity with travelling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 03 Nos installed at CTVS .
10 passenger elevator of 680 Kg capacity with travelling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 02 Nos installed at CTVS .
250 Kg Dumb Waiter (G+1) (Make : KONE Elevator) - 01 Nos installed at CTVS .
250 Kg Dumb Waiter (G+2) (Make : KONE Elevator) - 01 Nos installed at CTVS .
Notes for item No. 1.00 to 1.07: (i) The above maintenance shall be done through OEM of existing lifts. Please also refer Sch 'A' Notes. (ii) The contractor shall have to submit MOU from OEM M/S Thyssen Krup Elevator Company India Ltd ( for Item No. 1.01 to 1.03) & M/S Kone ELEVATOR INDIA Pvt Ltd (for Item No. 1.04 to 1.07). (iii) The rates quoted shall be inclusive of T&P required for carrying out repairs, stationary for maintenance of record all as specified. (iv) All the cleaning items (Dusting cloths, floor/Glass cleaner, SS steel cleaner, broom etc) shall be provided by the contractor and rates deemed to be included in the quoted rate. Otherwise a penalty of Rs. 100/- per day will be charged. (v) Any items not covered in Sch 'A' (excpet car cabin, landing door, sheave rim and Srl item No 02 to 20 of Sch 'A') shall be deemed to be included in the unit rate quoted for above items for the smooth functioning of lifts and the contractor may quote the rate accordingly. Contractor is expected to inspect the lift before quoting the rate and Lifts will be handed over in the same condition. No claim will be admissible thereof.
Notes for item No. 1.00 to 1.07 (contd.):- (vi) Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, penalty shall be charged as given below:- (a) up to 1st day- NIL (b) 2nd day- Rs 1000/- day (c) Subsequency for every days - Rs 2000/day. (vii) Contractor shall be responsible to register the day to day complaints of lifts and addressed the same with in the stipulated timeframe and the complaint register will be putup to the JE / Engr-in-charge on daily basis. (viii) The comprehensive / preventive / periodical maint incl fortnightly, monthly, quarterly, half yearly inspection / testing as per service manual or as per IS standard will be submitted to Engr-in-charge. (ix) Contractor shall submit safety security certificate of lifts from OEM in every month as per performa mentioned in tender documents. (x) Adequate arrangements shall be made to dewatering the lift pit as and when water accumulates. Cost Should be included in the quoted rate. Otherwise penality of Rs 500 per day per lift will be recovered from the contractor. (xi) Contractor shall be responsible to update the imp tele number and safety precautions of inside the car cabin of each lifts and update the same time to time.
Supply & fix in replacement of maintenance free Battery, 12 V 7AH complete all as specified & directed.
Supply & fix in replacement of ARD/ERD Battery EBD Mono 12 V 12 AH all as per site requirement complete all as specified & directed.
Supply & fix in replacement of ARD Battery EBD Mono 12 V 18 AH all as per site requirement complete all as specified & directed.
S&f in replacement lithium Ion batteries (alkaline) 9v complete all as directed.
Supply & fix in repair of 1350 Rpm Car Fan/blower as per existing type complete all as specified & directed. Make : Bajaj, Usha, Havells.
Supply & fix in replacement travelling cable multistranded copper conductor of size 12 core 0.5 sqmm all as directed by Engr-in-Charge.
S&f in replacement copper cable 1.5 Sqmm single core, 1100V PVC round sheathed flexible type complete all as directed.
S&F in replacement RCCB/RCBO in sheet metal enclosure 40 Amps, 300mA, four pole, 415 Volts complete all as directed.
S&F in repair MCCB 4 pole 63 A 16 kA in sheet metal enclosure fix to wall complete all as directed.
S&F in repair MCCB 4 pole 160 A 16 kA in sheet metal enclosure fix to wall complete all as directed.
S&F in replacement MCB SP 6 to 16 Amps complete all as directed.
S&F in replacement MCB TPN 63 Amps complete all as directed.
Supply and fix in repair, Metallic body exhaust fan of 350/380 mm sweep, single phase including necessary addn/altn to accommodate at the existing location or making provision by cutting/chasing wall and making good the disturbed surfaces, matching with the existing colour of wall all as directed by Engr-in-Charge.
Supply & fix in repair as in shaft light of lift environmental friendly, ultra modren, energy saving LED bulk head 10W IP 65 in die cast aluminium housing & frosted glass with all connection incl wiring all as per site requirement complete all as specified and directed.
S&F in repair decorative ultra slim linear LED , 2 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable up to main connection all as per site requirement and directed by EIC Make- Havells /Philips/Surya .
S&F in repair decorative ultra slim linear LED 4' long (18 W) lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack complete with connecting up with three core twisted flexible copper conductor cable up to main connection all as per site requirement.
S&F in replacement 07 W ultra slim decorative aluminium casted, recess mounted round/square fixture (as per existing size and type) in white finish with opal diffuser and electronic driver, suitable for low depth ceiling of lift complete all as per site requirement directed by Engr-in-Charge. Make : Surya/Havells/Bajaj
M&L in reapir for earthing with Galvanised Steel earth plate electrode of size 600 x 600 x 6mm thick directly burried in ground (earth pit not less then 4Mtr deep below ground level with tope edge of earth plate not less than 1.5 Mtr below the ground level connected by GI Earth Strip of Size 32x 6mm thick by means of Bolts, Nut,Check Nuts and Washer of GI or Steel GI Pipe 40mm Bore light grade for protection of earthing strip, PCC CHAMBER 1:4:8 TYPE D-1 using 20mm graded stone agg. Internal surfaces of chamber shall be plastered 12mm thick in CM 1:4 funnel with wire guage of 22 guage(0.63mm) 8 mesh per linear inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm grade stone agg. reinforced with 8mm dia TMT Bar @80mm C/C both ways and charcoal dust and common salt all as specified and shown in electrical plate No of 5 of SSR part-I including excavation of earth work, returning , filling, removing surplus soil not exc 50 m and connecting the earthing to an earthing test point as specified and testing on completion
Supply & fix in repair GI strip 32x6mm, buried in ground or fixed to wall incl saddling etc for loop earthing.
M/s Adhikari construction co.
MB Enterprises
M/s Dhapola Elevator and Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .