Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC | ₹1.7 Cr | 1 | Accepted-AOC Being lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
6 Feb 2020, 6:00 pmClosed
CE 31 ZONE
CE 31 ZONE
CONVERSION OF 01 X IGLOO INTO AC MSL SHED AND ALLI
2019_MES_265310_2
CONVERSION OF 01 X IGLOO INTO AC MSL SHED AND ALLI
Open Tender
Civil Works
Lump-sum
554 days
GE 874 EWS KUPWARA
AS PER TENDER DOCUMETNS
6 documents required · 6 mandatory
₹1,000
Yes
GE 874 EWS KUPWARA
₹2.1 L
Yes
27 Aug 2020
5 Oct 2019
11 Feb 2020
5 Oct 2019
6 Feb 2020
2 Nov 2019
9 Oct 2019 - 15 Oct 2019
Amount
Sch 'A' Part-I ( Building works) carried forward from pre-priced Schedule.
Sch 'A' Part-II (Sec-I) ( Repair works) carried forward from pre-priced Schedule.
Sch 'A' Part-II (Sec-II) ( Repair works) carried forward from pre-priced Schedule. Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Chipping out existing internal/external wall surfaces incl (RCC beam, slab & Columns etc) of existing Igloo No-3 cleaning/washing the surface with water thoroughly then apply diluted cement modified grout (diluted latex 1:6) on roughened and cleaned surfaces to sealing the porosity/and minor cracks in existing surfaces incl (RCC wall, beam, slabs etc) at any height, complete all as specified and as directed. (Note :- (i) Application and consumption of "Diluted Latex/Sika SBR LATEX" shall be as per manufacturer's instructions). (ii) Work shall be carried out only through authorised applicators of approved manufacturers and they have taken a guarantee for no leakage and seepage in that treated surfaces for ten years)
Preparation of existing substrate surfaces by cleaning using wire brush and water jet in order to remove all loose particles and to ensure that the surface is free from any foreign material and drilling of holes at locations as directed by Engr-in-Charge and fixing nozzles to required depth and diameter by mechanical means and sealing using Fosroc plug or equivalent and applying pressure by mechanical mean to inject Sika injection 101 h or equivalent followed by Sika injection 202 or equivalent as per manufacturers instructions and plugging the holes all as specified and as directed by Engineer-in-Charge. (Note :- Work shall be carried out only through authorised applicators of approved manufacturers and they have taken a guarantee for no leakage and seepage in that threated surface for ten years)
Supply only Sika or equivalent (Plastering liquid water proofer) all as specified and directed.
M&L for preparing plastered/un-plastered surfaces of RCC wall, beams, columns and all concrete duly cleaning unsound surfaces by pressure washing throughly and mopping the surfaces complete to remove loose materials, dirt, debris etc and applying crystalise coating using two coats of Sika 101h or equivalent in two coats over a coat of bonding primering Sika SBR or equivalent all as specified by manufacturers and as directed by Engineer-in-Charge. (Note :- Work shall be carried out only through authorised applicators of approved manufacturers and they have taken a guarantee for no leakage and seepage in that threated surface for ten years)
Taking out/striping out all existing roof treatment including layers of bitumen felt, concrete padding and benching including hacking for key, scrubbing down with water complete to receive new roof treatment at any height including rubbish off the premises upto a distance exc 250m but n.exc 500m complete all as specified and directed.
M&L for preparation internal old plastered/un-plastered wall & surfaces of any description wood, steel, iron concrete, brick, stone etc and applying two coats of fire resisting paint over a coat of wall putty exceeding 10cm in width of girth after complete removal of existing treatment upto 7.5 m height from ground level (GL) complete all as specified and directed.
M&L for preparation external old plastered/un-plastered surfaces of RCC braces, beams, columns and all concrete applying two coats of weather coat paint (with camouflage pattern) over one coat of primer after complete removal of existing treatment complete all as specified and directed.
Dismantling of mud mixed with rubble/brick bats from roof incl mud plaster or leeping if any incl removal to a distance exc 50m and n.exc 250 mtr compelte all as specified and directed.
20 mm thick rendering in CM 1:4 on roof surface incl finished even and smooth incl a coat of bonding agent (as directed by manufacturer) all as specified and directed.
Laying of 400 micron thick geomembrane (HDPE) incl all necessary materials like adhesive etc complete as per manufacturer directions (work will be executed through manufacturer app aplicater)
Raising of earth (as reteived from item above) after screening and again mixing with brick bats segregated during survey as per direction of Engineer-in-charge and laying on roof in layers n exc 30 cm thick complete all as specified and directed.
Eath filling in layers as in roof in layers n exc 30 cm thick incl mixing with brick bats n exd 75mm in size complete all as directed by Engineer-in-Charge and as specified. (Earth will be brought from outside MoD land)
Sch 'A' Part-III (Sec-I) (Internal Electrification carried forward from pre-priced Schedule.
Sch 'A' Part-III (Sec-II) (Internal Electrification) Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
VELOCITY ceiling fan AC single phase 230V/240V 50 Hz of size 1200 mm sweep,290 rpm and complete with connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts complete all as specified and directed. Make: Havells Model-Velocity or equivalent in Crompton/khaitan
Delite Plus 22 W decorative ultra slim round LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack 1x 22 W LED tube (4 ft) having minimum 2000 lumens with extruded engineering plastic housing polycarbonate diffuser, G-13 polycarbonate end cover, the LED with 120 degree vie angle>120 lumen/watt, lumen maintenance 70% at 50000 hrs colour temperature of 6500 K>70 colour rendering the driver must be integral APFC and constant current type having THD<20% and power factor>0.9 with reverse polarity protection and open circuit protection. Make: Havells Model No LHEXBTP7IN1S022/equivalent in CG, Philips including 1x22 watt LED tube.
ENDURA PEARL New generation energy saving and environment friendly long life LED street light fitting 20W LED 5700 K in and including LED lamps made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 65 protection and impact resistance of IK07 complete all as specified and testing on completion and includingn GI wall mounting bracket 40 mm dia 1.2 Mtr long incl 30 degree bend with 02 No FI clamps 25x3mm size with necessary nut bolts etc. Make - Havells Cat part No ENDURAPEARLLSL20WLED757SASYTOPC/ Equivalent in Philips, CG .
MCB SP 240 V, 50 Hz, 10 KA , 'B' series of rating 6 Amp make: Havells cat Part No - DHMGBSPF006 OR equivalent SCHEINDER/C&S.
MCB SPN 240 V, 50 Hz, 10 KA , 'C' series of rating 40 Amp make: Havells cat Part No - DHMGCSNF040 OR equivalent SCHEINDER/C&S.
MCB SP 16 Amps 240 V, 50 Hz AC , C curve made from moduled self exitinguising thermostat plastic and suitable for :'c' curve, 10 KA braking capacity. Make -Schneider Cat part No. A9N2P16C or equivalent in legrand/ hager/seimens
Sheet metal enclosure SPN factory made, double door for DBs 230 Volts,single pole and neutral 6 way complete all as specified and directed. Cat part No. DSSDBXO195 Make- Havells OR equivalent in Scheinder/Hager
Sch 'A' Part-IV (Lightening Protection Works) carried forward from pre-priced Schedule
Schedule 'A' Part-V (DG Set) Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply ,installation,commissioning and testing of silent diesel engine driven generating set with canopy and acoustic as per guide line issued by CPCB and environment Act(415 volts,AC supply 3 phase 50 HZ four wire complete suitable for giving an output of 40 kva (32KW) after considering factor conforming to IS-10001/10002 and alternator as per IS-13364 complete at 1610 metre altitude above mean sea level and capacity for operating between temperature range -15 degree celcius to +35 degree celcius at Kupwara area of (J&K) and alternator of suitable capacity coupled with each other and cabable of taking 10% over load for one hour on every 12 hours as per BS-5514/649 with flexible coupling mounted on common base plate on the antivibration pads on foundation as recommended by manufacture.The DG Set shall comprising of electric starter motor with batteries ,turbocharger, water cooled and comprising all standard fittings/fixtures and all piping etc water cooled with radiator complete with in built tank of capacity as per manufacturers specification all as specified and comprising following:- Makes : i. Crompton Greaves, ii. Cummins, iii. Kirloskar Oil engines Note:- Rate for Srl Item No 7.01 to 7.06 shall be quoted against Srl No 7.01. The cost of components of DG Set as stated under Item No 7.02 to 7.06 shall be deemed to be included in the rate quoted against srl Item No 7.01 and nothing extra shall be admissible on this Account.
(A) DIESEL DRIVEN ENGINE Developing a net rated output of minimum 56 BHP or next higher capacity suitably matched with alternator to give a net rated output of 40 kva the engine should be capable of delivering the required output at 1500 rpm as per BS 649 under NTP condition with provision of 10% over load for one hour in every 12 hour and interlia with the following accessories and all as specified.
(i) Fly wheel to suit flexible coupling and fly wheel housing (ii) Air cleaner as per manufacturer specification. (iii) Fuel injection rotary nozzle pump (iv) Electric governor (v) Oil filter and mounting (vi) Flexible coupling with guard nuts bolts (vii) Fuel filter and mounting (viii) Lubricating oil pump and oil cooled (ix) Starter motor as per manufacurer design (x) Lubricating Oil Cooler (xi) Exhaust silencer ,industrial type with exhaust pipe of length , beyond impeller from wall from DG Set room (xii) Drip tray (xiii) Battery charger suitable capacity fitted with transformer/ rectifier unit DC ammeter /off/trickle/ boost switch ,DC volt meter and other standard fittings hour running meter,KWH meter etc. (xiv) 01 No maintenance free battery 12 V Battery,180 AH (xv) Cold starting Kit.
(B) ALTERNATOR The above engine will be coupled through flexible coupling on an indegeous alternator mounted on strong steel fabricated common base frame suitable for mounting in an acoustic. The alternator will be 3 phase 50HZ 1500 RPM self regulating self-exciting type and generating 40 kva output at 0.8 power factor 4 wire ,415 Volts AC supply after considering degradation factor at 1610 M altitude above mean sea level at Kupwara area of J&K with provn of 10%over load for one hour in every 12 hours running at 1500 RPM , the alternator should be screen protected and fitted with shield ball/ roller bearing confirming to BS 2613/IS 4722. (C) MANNUAL CONTROL PANEL The in built control panel body will be fabricated out of 16 SWG MS sheet. Panel will be suitable for canopy mounting indoor installation ,dust & vermin .
(h) Totally enclosed busbar having copper 4 strip of size 40x5mm thick and Neutral respectively supported on porcelain insulated with colour red, yellow, blue and black. (j) Necessary foundation to fix the panel board and connecting testing and commissioning all as specified. (k) Complete wiring of panel board with suitable size copper strip from incoming MCCB to bus bar and Busbar to outing MCCB with RYB colour coated.
Sch 'A' Part-VI (Sec-I) (Road, Path, Culvert & Hardstanding Works) carried forward from pre-priced Schedule.
Schedule 'A' Part-VI (Sec-II) (Road, Path, Culvert & Hardstanding Works) Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M & L for 150mm thick (Compacted thickness) wet mix macadam (WMM) inntwo equal layers 75mm thick each layer with caorse aggregates of grading 02 (63 to 40mm size) or of grading 03 ( 50 to 20mm size) spread, watered, rolled with 8 to 12 tonne power roller and consolidated to required gradient and camber complete all as specified and directed.
Preparation of unsurfaced WMM surface by brushing with wire brush for removing caked mud etc/sweeping with brooms and finally fanning cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a priming coat with bitumen primer (VG-30) @ 10 Kg/10 Sqm, bituminous premix asphaltic semi dense concrete 40mm consolidated thickness with 5.5% paving bitumen (VG-10) of binder content by weight of total mix, rolled and conpacted to required camber and gradient with 8 to 12 tonner power roller complete all as specified and directed.
Sch 'A' Part-VII (Stone Pitching Works) carried forward from pre-priced Schedule.
Sch 'A' Part-VIII (Sec-I) (External water Supply works ) carried forward from pre-priced Schedule
Schedule 'A' Part-VIII (Sec-II) (External water Supply works ) Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of brick masonry stagging for overhead water tank 2.4m height from ground level including necessary earth work in any type of soil, complete all as shown on drawing No CESD/TD-1101/2011 sheet 1/1 dated 01 Dec 2011 complete all as specified and directed.
Valve pit of size 90cmx90cmx105cm(internal dimesnsions) brick masonry construction, including all necessary excavation and earth work in any type of soil, returing filling in disposal of surplus soil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), PCC coping in PCC (1:2:4) Type B-0 using 12.5mm crushed stone graded aggregate, brick masonry in cement (1:4) internally, finished even and fair and pointing flush externally as the work proceedsin the same mortar, mild steel angle iron 50x50x6mm frame, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS Work with two coats of synthertic enamel paint of the tint as apporved b y the GE over a coat of red oxide primer and painting all the MS embedded in PCC With two coats of black bituminous paint, complete all as specified and directed.
Sch 'A' Part-IX (Sec-I) (External Electrification works ) carried forward from pre-priced Schedule
Schedule 'A' Part-IX (Sec-II) (External Electrification works ) Note : This schedule is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L for weather proof/out door type mild steel 1.6 mm thick junction box of standard size front door openable and having locking arrangment key type, including PVC cable glands for incoming and out going cables, including following items:- (a) Aluminium bus bar of size 20X5 mm thick - 02 nos duly fitted on suitable insulators, (b) MCB SPN 6 Amp - 01 No
Supply and fixing GI bracket for fixing of street light fittings bend to shape, made out of 32mm GI pipe light grade upto 1.5m long fixed with and including clamps made from flat iron of size 40x4mm, MS clamps bolt, nuts & washers & two coats of aluminium paint over a coat of red oxide primer, complete all as specified
Supply, laying, jointing, commissioning and testing cable (armoured) XLPE (Aerial Bunched Cable) insulated screened followed by copper tape, PVC outer sheathed conforming to IS 7098 (PII) all three core twisted around bare messenger wire as per IS 398 armoured electric cable (heavy duty) with stranded aluminium conductors, 11000 volts grade of cross sectional size 3-core X 70 sqmm + 1 x 50 sqmm complete all as specified and directed.
Supply and fixing LED street light fitting, of capacity 90 watt with having high pressure die cast aluminium housing with sealed toughened glass cover suitable for pole mounting, protection IP 65 complete, all as specified and directed. Make Havells Cat part No Endura Cityliner NEO 90 W LED 757SASYBOTG.
Sch 'A' Part-X (Area drainage) carried forward from pre-priced Schedule.
Sch 'A' Part-XI (Fencing, Security wall & Gate) carried forward from pre-priced Schedule.
Sch 'A' Part-XII (Protective Work) carried forward from pre-priced Schedule.
Sch 'A' Part-XIII (Site Clearance and Earth work) for works covered under Sch 'A' Part-II to XII) carried forward from pre-priced Schedule.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .