Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L1 | Accepted-AOC ok | |
| 2 | L2₹8.8 L+₹1.4 L (19.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
24 Oct 2022, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Repair/Maint of DG Set, AMF panel, replacement of UNSV UG Cable and connected works at AF Stn Bihta.
2022_MES_554090_1
8260/BHT/E8
Open Tender
Civil Works
Item Rate
150 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹20,000
Yes
21 Nov 2022
24 Sept 2022
26 Oct 2022
24 Sept 2022
24 Oct 2022
8 Oct 2022
Amount
All as per item no 1 above but DG set of cap 75 KVA make Kirloskar installed at AF Net Site 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 62.5 KVA make Kirloskar installed at pump house No 3 complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at P H No 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 40 KVA Make Sonilika installed at Tropo perimeter SS No 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC sub station (Alt) complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 40 KVA Make Sonilika installed at OTES complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC S/S complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Main Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Sub Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at Sub stn No 2 (Tropo) complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at 10 ASC complete all as specified and directed by Engr-in-Charge.
Inspection, maintenance and servicing of DG set 75 KVA installed at AF Net site 1 including Alternator, excluding AMF panels connected to DG sets for routine check up of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc, complete all as specified and directed by Engr-in-Charge. Note:- Engine oil & Coolant oil will be measured and paid separately.
All as per item no 13 above but DG set of cap 75 KVA installed at AF Net Site 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 62.5 KVA installed at pump house No 3 complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 40 KVA installed at P H No 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 40 KVA installed at ATC sub station (Alt) complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 40 KVA installed at OTES complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 40 KVA installed at ATC S/S complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 25 KVA Installed at Main Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 25 KVA Installed at Sub Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo) complete all as specified and directed by Engr-in-Charge.
All as per item no 13 above but DG set of cap 15 KVA Installed at 10 ASC complete all as specified and directed by Engr-in-Charge.
Supply only engine oil SAE 20W-40W. Make:- Volvoline / IOC
Supply & filling radiator coolant Make:Volvoline / IOC
Servicing & Maintenance of AMF panels pertains to 75 KVA DG SET installed at AF Net site 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points complete all as specified and directed by Engr-in-Charge. Note:- Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
All as per item no 27 above but DG set of cap 75 KVA installed at AF Net Site 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 62.5 KVA installed at pump house No 3 complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 40 KVA installed at P H No 2 and all as directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2 complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 40 KVA installed at ATC sub station (Alt) complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 40 KVA installed at OTES complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 40 KVA installed at ATC S/S complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 25 KVA Installed at Main Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 25 KVA Installed at Sub Guard room complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo) complete all as specified and directed by Engr-in-Charge.
All as per item no 27 above but DG set of cap 15 KVA Installed at 10 ASC complete all as specified and directed by Engr-in-Charge.
Removing the self starter 12 Volt DC from the engine of 15 to 75 KVA DG sets and taking to work shop for rewinding of armature/field including replacement of brush and bush and refixing the same to the engine and testing complete all as specified and directed by Engr-in-Charge.
Supply only 12 V DC stopping solenoid suitable for 15 to 75 KVA DG sets. (Spares for executing the Sl item Nos. 27 to 38)
Supply only Water Temp gauge with adapter. (Spares for executing the Sl item Nos. 27 to 38)
Supply only Oil Temp gauge with adapter. (Spares for executing the Sl item Nos. 27 to 38)
Supply only Oil pressure guage with pipe. (Spares for executing the Sl item Nos. 27 to 38)
Supply only AC / DC Timer. (Spares for executing the Sl item Nos. 27 to 38)
Supply only PLA Relay with Base. (Spares for executing the Sl item Nos. 27 to 38)
Supply only Volt meter DC. (Spares for executing the Sl item Nos. 27 to 38)
Supply only Ammeter DC. (Spares for executing the Sl item Nos. 27 to 38)
Supply and fixing Battery 12 Volts 80AH including inbuilt battery charger complete all as specified and directed by Engr-in-Charge.
Supply and fixing Battery 12 Volts 100AH including inbuilt battery charger complete all as specified and directed by Engr-in-Charge.
Taking out unserviceable power contactor and Supply and fixing power contactor suitable for AMF panel up 40 to 75 KVA , Make : TC,LC1FDP 3304A
Supply and fix in repairs Air filter element as per existing make for 62.5 to 75 KVA DG Set
Supply and fix in repairs Air filter element as per existing make for 40 KVA DG Set
Supply and fix in repairs Air filter element as per existing make for 15 to 25 KVA DG Set installed at (SER No 21 &22)
S & F dynamo fan belt set suitable for DG Set 62.5 to 75 KVA Make : Kirloskar (2.00 to 2.50 for belts) Make: - Kirloskar, /Power king/power grip GTX/dunlop
S & F dynamo fan belt set suitable for for DG Se 15-40 KVA Make : Cummins Jakson
S & F water pump suitable for 62.5 to 75 KVA DG Set Make :Kirloskar, Make: Kirloskar /Power king/power grip GTX/dunlop
S & F water pump suitable for for DG Se 40 KVA Make : Cummins Jakson
S & F water hose pipe set with clamps suitable for 62.5 - 75 KVA DG Set Make: Kirloskar
S & F water hose pipe set with clamps suitable for 40 KVA DG Set Make : Cummins
S & F Relay suitable for Kirloskar Make DG Set 62.5-75 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing complete all as directed. Make: L&T/Siemens
S & F Relay suitable for Kirloskar Make DG Set 40 KVA (existing type & voltage -240 Volts AC) in AMF panel and making connections including testing complete all as directed. Make: L&T/Siemens
S & F Auxiliary contact suitable for Kirloskar Make DG Set 62.5-75 KVA (Existing type) with logic units. Make: L&T/Legrand/ Havells/ Siemens
S & F Main contactors four pole, 220 Volt suitable for 75 KVA DG set of existing model complete all as directed. Make- L&T Havells, legrand etc
S & F SMPS unit suitable for DG Set 62.5 - 75 KVA DG Set for battery charging including making connections and testing etc complete as specified and as directed.
S & F in replacement of unsv MCB DB 220 volts 12 way double door complete all as specified and directed by Engr-in-Charge.
Repair and maintenance of EOT crane 0.5 / 2.5 Ton installed at Rador by checking all mechnical and electrical equipment/system for normal working and testing with the load if provided by user including greasing,oiling and replacing minor spares and consumbles complete all as specified and directed by Engr-in-Charge.
Supply and fix breaker motor coil for the EOT crane 0.5 to 2.5 Ton complete all as specified and directed by Engr-in-Charge.
Supply and fixing single Phase Static Energy Meters,ISI Marked, Digital Energy meter for netmetering with enclosure having capacity 5-30Amp, 240V, Accuracy Class 1.0,DLMS Compliant,Optical Port and Load survey including suitable SMC Meter Box, sealing arrangement along with 2 nos. polycarbonate meter seal and making connection and complete all as specified and directed by Engr-in-Charge.
Material, Labour and checking for fire alarm system incl rectification of loop, smoke detector, hooter, mother board and MCP and if necessary armoured wire of 1.5 sqmm 2 core need to be supplied complete all as specified and directed by Engr-in-Charge.
Supply and fixing of ON load change over switch having current rating 200 Amps, 415 volts, 50 Hz, 4 pole with steel sheet encls conforming to IS :13947(part-3) IEC : 60947-3, complete all as specified and directed by Engr-in-Charge.
Dismantling of upper portion of Diesel Engine 75 KVA ,Water cooled, Turbo charged 1500 RPM vertical type installed at AF stn Bihta and Top over hauling and repair / servicing of engine including taking out radiator, fuel pump, hydraulic governors, lub oil pumps, water pump, turbo charger etc .Assembling of engine after replacement of UNSV defective parts complete all as specified and directed by Engr-in-Charge. Note:-Cost of defective parts included in quoted rate.
M & L for grinding, cutting of cylinder heads including inserting of new valves(Exaust and inlet) valve shafts guide, called valve spring etc complete all as specified and directed by Engr-in-Charge. Note:-Cost of Spares as required included in quoted rate.
Repair and overhauling and calibration of fuel pump complete with replacement of warm out parts such as bearings plunger, inplellar and oil seal etc including calibration of injector and refixing fuel injector pump and injector including testing complete all as specified and directed by Engr-in-charge.
Supply and fix on wall ' DO AND DON'T chart for electric installation and made out of plastic based paper with glass cover and aluminium frame of size 0.80 mtrs x 1.00 mtrs including two numbers clamp for hanging arrangements with instructions written in language in Hindi or English complete all as specified nd directed by Engr-in-charge.
Supply and fixing AVR complete all as directed by Engr -in-Charge.
Supply and fixing AMF panel of capacity upto 40 KVA DG set complete all as specified and directed by Engr -in-Charge.
Disconnecting and taking down of smoke detectors and refixing the same in false ceiling all as specified and as directed by Engr-in-Charge
Bikarma Enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .