Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.6 Cr+₹2.0 L (1.25%)Rejected-AOC C141 SUN CITY SECTOR 35 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.6 Cr+₹2.0 L (1.25%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.7 Cr+₹13.5 L (8.55%)Rejected-AOC | ₹1.7 Cr+₹13.5 L (8.55%) | L3 | Rejected-AOC Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
23 Mar 2021, 6:55 pmClosed
EE PHED No.1 Rohtak
PHED No.1 Jhajjar Road Rohtak
Sanghi augmentation of w s scheme providing functional household tap connections and laying the balance pipe lines in village sanghi under jjm Construction of open inlet channel, brick lined SandS tank high level tank filter bed clear water tank repa
2021_HRY_163858_1
DNIT Approved vide SE Endst No. 501 dt. 13.03.2021
Open Tender
Civil Works
Works
450 days
VPO SANGHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.9 L
Yes
9 Apr 2021
15 Mar 2021
24 Mar 2021
15 Mar 2021
23 Mar 2021
15 Mar 2021
Amount
RAW WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame at water works 2800 LPM X 12 M. Head
CLEAR WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame at water works 2800 LPM X 45 M. Head
CLEAR WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame at Boosting Station 1000 LPM X 45 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items
For 2 no Pumping Sets of 2800 LPM x 12 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 2800 LPM x 12 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 2 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 2 no Pumping Sets of 2800 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 2800 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 2 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 2 no Pumping Sets of 1000 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 1000 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 2 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc.
10mm2 3core
25mm2 3core
Specials for Pumping Machinery Supply, erection, fixing & testing of CI Double flanged pipe complete with all jointing materials
Providing & fixing of 200 mm i/d floating arm / floating drum fabricated with 16 guage GI sheet along with MS bolt, CI flange welded with 1 side collor & 1 side wire mesh to prevent foreign elements from entering into the floting arm, fixed with swivel bend, CI base plate fixed with anchor bolts in tank hodi complete in all respect.
Taking out filter all layers of filter media from the filter beds and placing it out side the fiter bed.
Taking out RCC bed plates from the filter beds and placing the out side ( 0.45 x 0.45 x 0.05 m)
washing of Drains & Main Drain with the help of wire brush
Placing of RCC plates after washing & cleaning
Placing in layers of filter media from top layer to bottom layer after washing, cleaning & screening complete in all respect as per direction of Engineer-in-charge.
Supply erection, testing & commissioning of light fittings including complete wiring alon with all material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. ( for Store))
Providing & fixing in position GI elbow ISI marked complete in all respect 15 mm i/d 1154 x 4 = 4616
Providing & fixing in position GI Nipple ISI marked complete in all respect 15mm x150mm /100 mm 1154 x1 = 1154
Providing & fixing in position GI Socket ISI marked complete in all respect 15mm i/d 1154 X 1 = 1154
Bidder Name
Amount
SATVIR SINGH CONTRACTOR(GSTN-06ABNPS8716P1ZO)
Lalit Kumar(GSTN-06ALGPB5309Q1ZY)
Surinder Singh Hooda(GSTN-06AABPH9599L2Z1)
Surinder Singh Hooda
SATVIR SINGH CONTRACTOR
Lalit Kumar
SATVIR SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .