Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.8 L+₹2.4 L (8.88%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.0 L+₹6.7 L (24.3%)Rejected-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹36.1 L+₹8.7 L (31.7%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.9 L+₹10.5 L (38.3%)Rejected-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | ARUNOTHAYA TRADERS L2 | Shiva Shakthi Electrical Enterprises L4 | ADR ENTERPRISES L1 | navreet construction L3 | Deepak Electricals L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for taking out old RCC pole of any size along with old Street light fittings of any capacity complete including breaking PCC and clearing the debris from the site complete all as specified and directed. | 80 | Each | 1,000 ₹80,000 | 250 ₹20,000 | 600 ₹48,000 | 200 ₹16,000 Lowest | 500 ₹40,000 |
| 2.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. | 314 | CUM | 300 ₹94,200 | 280 ₹87,920 | 200 ₹62,800 Lowest | 250 ₹78,500 | 240 ₹75,360 |
| 3.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m in depth for foundation (Laying of underground cables) in hard/dense soil and getting out complete all as specified and as directed. | 1.73 | CUM | 450 ₹778.5 | 350 ₹605.5 | 200 ₹346 Lowest | 300 ₹519 | 325 ₹562.25 |
| 4.00 | Returning, filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. | 251.2 | CUM | 50 ₹12,560 | 45 ₹11,304 Lowest | 80 ₹20,096 | 60 ₹15,072 | 50 ₹12,560 |
| 5.00 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 62.54 | CUM | 50 ₹3,127 | 45 ₹2,814.3 Lowest | 80 ₹5,003.2 | 60 ₹3,752.4 | 50 ₹3,127 |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed. | 7,250 | Each | 33 ₹2,39,250 | 25 ₹1,81,250 Lowest | 26 ₹1,88,500 | 40 ₹2,90,000 | 40 ₹2,90,000 |
| 7.00 | M&L for Foundation for steel tubular poles of concrete 1:2:4 Type B-2 (using 40 mm graded stone aggregate) for foundation of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed. | 4.32 | CUM | 4,500 ₹19,440 | 3,600 ₹15,552 Lowest | 5,000 ₹21,600 | 6,200 ₹26,784 | 7,500 ₹32,400 |
| 8.00 | M&L for Foundation for steel tubular poles of concrete 1:4:8 Type D-2 (using 40 mm graded stone aggregate) for foundation of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed. | 23.76 | CUM | 4,500 ₹1,06,920 | 3,600 ₹85,536 | 4,800 ₹1,14,048 | 3,500 ₹83,160 Lowest | 6,000 ₹1,42,560 |
| 9.00 | M&L for Foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed. | 1.58 | CUM | 4,500 ₹7,110 | 4,500 ₹7,110 | 5,000 ₹7,900 | 4,000 ₹6,320 Lowest | 6,000 ₹9,480 |
| 10.00 | M&L for Coping, steel tubular poles 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed. | 2.1 | CUM | 4,500 ₹9,450 Lowest | 4,500 ₹9,450 Lowest | 5,000 ₹10,500 | 5,500 ₹11,550 | 8,000 ₹16,800 |
Tender Value
₹42.3 L
EMD Value
₹84,560
Closing Date
24 Feb 2026, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIR/REPLACEMENT OF OLD RCC SECURITY LIGHT POLES AND CONNECTED ITEMS FROM RO PLANT TO DSC MANDIR GATE AT DOMESTIC AREA AT AFS YELAHANKA
2026_MES_751162_1
8468/E8
Open Tender
Civil Works
Item Rate
180 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹84,560
Yes
27 Mar 2026
3 Feb 2026
3 Mar 2026
3 Feb 2026
24 Feb 2026
17 Feb 2026
M&L for taking out old RCC pole of any size along with old Street light fittings of any capacity complete including breaking PCC and clearing the debris from the site complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m in depth for foundation (Laying of underground cables) in hard/dense soil and getting out complete all as specified and as directed.
Returning, filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
M&L for Foundation for steel tubular poles of concrete 1:2:4 Type B-2 (using 40 mm graded stone aggregate) for foundation of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
M&L for Foundation for steel tubular poles of concrete 1:4:8 Type D-2 (using 40 mm graded stone aggregate) for foundation of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
M&L for Foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
M&L for Coping, steel tubular poles 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.
Supply and fix, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core all as per IS, complete all as specified and directed.
Supply and fix, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as per IS, complete all as specified and directed.
Supply and fix, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core all as per IS, complete all as specified and directed.
Supply and fix, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core all as per IS, complete all as specified and directed.
Supply and fix of light grade galvanised mild steel pipe 40 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed as for cable protection. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule)
M&L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure complete all as specified and directed.
Supply and fix, erecting of steel tubular swaged poles with cast iron base plate of size 300 mm x 300mm x 6mm, final taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with Sky Blue & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over Sky blue painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed.
Supply and fix of bracket made out of GI tubing single piece bended type(not welded) at proper angle of size 40 mm dia, light grade 120cm long including painting with aluminium paint over one coat of red oxide to the bracket, MS clamps 02 Nos with 04 Nos nuts bolts and washer etc complete including 4sqmm 2.0 core flexible Copper cable PVC insulation 6.5 mtr long in PVC conduit with clamp U type from junction box to connector of street light fitting complete all as specified and directed.
S&F in repair pole mounted junction box (Street light box) made up of FRP/ Polycarbonate with sliding type doors fits to base by 3 phase busbar insulator - 04 Nos for street lighting system with nuts and bolts with fixing arrangement outdoor type of dimension 240 x 130 x 110 mm for with suitable screen printed skull and bones for danger notice on middle and top cover of the box complete all as specified and directed.
S&F in repair three single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s one complete all as specified and directed.
S&F in repair 230V 10KA 'C' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the Junction box/DB complete with connection testing and commissioning complete all as specified and directed.
S&F in repair of 7 metre high hot dipped, synthetic enamel grey colour coated octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade "J" type foundation bolts and numbering of poles, in white paint over black painted circle of dia 10 cm at a height of 1.0m from bottom of pole with 5 cm large bold letters 2" (inch) wide etc with accessories as required including dismantling existing pole complete all as specified and directed.
S&F and commissioning of street light fitting 70W LED, new generation energy saving and environmental friendly long life led street light with Auto on/Off based on Lux Level sensitivity with LDR Sensor, THD less than 10, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 inc, 10KV External Surge Protection, Operating temp -01 Degree celcius to 45 degree celcius, CCT 5700 K, including 1.5 Sqmm 3 Core connecting wire for street light to pole box complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed. Note:- (a) Earthing value should be less than 5 ohms. (b) If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision.
Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 40mm and inner dia 32mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax or equivalent
Design, Supply, installation, testing and commissioning in repair outdoor Street light LT Panel double door of an advanced Distributed Electrical Load Regulation and Control Interface (15KW, 3-Phase) embedded within a unified telemetry-based automation matrix employing GPRS and GSM communication protocols. The apparatus shall be capable of sustaining a per-phase inductive/resistive load of 32A and facilitate multi-modal operability through TCPIP Protocol & encrypted MQTT/TCP Protocol, browser-based user interfaces, and dedicated Android-compatible mobile applications. Actuation sequences shall be dynamically regulated via photometric or astronomical controller stimulus referencing complete all as specified and directed. Technical Features: GSM multislot class 12 with GPRS coding scheme is CSI,CS2,CS3,CS4 Available And access information (24×7-365) Data logging: Minimum 2 months on Server Inbuilt RTC and auto sunrise/sunset calculation based on GPS Fault detection: Over/under voltage, overcurrent, overload, under load, over/under frequency Whatsup MSG OR Email alerts on power/fault events Battery backup: Min. 10–12 hours Operation Modes: GSM / continuous monitoring and remotely controlling through android app and website. example:-remotely On/off time, schedule set, update data interval frequency, and set RTC as per Server Time/ Bypass GPRS interface for live electrical data (kW, kWh, PF, I, V) CCMS controller (RTU) has inbuilt 16x2 LCD Display. CCMS controller (RTU) has inbuilt keyboard interface to set the schedule time Locally at site CCMS controller (RTU) has schedule ON/OFF time on its LCD display CCMS controller (RTU) has inbuilt RTC(Real TIME CLOCK) and its clock displays time and date on LCD Display CCMS controller (RTU) has inbuilt RTC(Real TIME CLOCK) and its clock displays time and date on LCD Display CCMS controller (RTU) has DLMS/ RS485 communication interface for meter communication parameters. Cabinet Enclosure: IP55-rated metallic structure mounted on fabricated mild steel angle iron pedestal (600mm elevation), anchored with PCC 1:2:4 Type B1 grouting. Scope includes decommissioning of legacy distribution panels. The panel should be CPRI Approved . The proposed system design and specifications shall be submitted to the Garrison Engineer (GE) for necessary scrutiny and prior approval. Execution of any part of the work shall begin only upon receipt of written approval from the GE
Supply and fixing in repair, “Lithium based Energy Efficient Integrated Solar Street Light of 40Watt” in rust proof Aluminium housing with Monocrystalline Solar PV Panel of 75W(-0/+4W)Mono , Lithium Battery 12.8V, 42AH(BIS Certified), IP 65, High brightness W-LED(150 Lm/watt) lamp with Aluminium reflector for better light distribution, Color Temperature 6500K +500K, Microcontroller based charge controller cum driver, automatic dimming function(with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 5 degree C to (+) 45 degree C, Charging time 1 day and Autonomy 2 days with dimming Protections: Short Circuit, overload, Reverse polarity and battery protections complete all as specified and directed.
Supply and fixing in repair of 6 metre high hot dipped, synthetic enamel grey colour coated octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet along with base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade "J" type foundation bolts and numbering of poles, in white paint over black painted circle of dia 10 cm at a height of 1.0m from bottom of pole with 5 cm large bold letters 2" (inch) wide etc with accessories as required including dismantling existing pole complete all as specified and directed.
Supply and fixing in repair of flexi strip trica ac led tricolor strip light street light for poles with optimum brightness and uniformity for perfect cove light, IP-65, 120 LED/Mtr with rated input power 8W per metre, LED Driver : AC Adaptor, input voltage 220-240V AC, frequency 50 Hz, Power factor, Protection open circuit LED reverse polarity, surge withstanding 2.0KV CCT 3000K/4000K/6500K suitable for working temp 0 to 100 degree Celcius and also protects against harsh environment outdoor complete all as specified and directed. Make : Havells/PHILLIPS/WIPRO/CROMPTON
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_841292.xls
BOQ • 0.43 MB
Tender8468.pdf
Tender Documents • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .