Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC LOWEST BIDDER. | |
| 2 | L2₹16.2 L+₹1.6 L (11.2%)Rejected-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L2 | Rejected-AOC NOT LOWEST BIDDER. | |
| 3 | L3₹17.2 L+₹2.6 L (17.7%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST BIDDER. |
| Sl No | Description | Qty | Unit | Paragon Electrotechnics L1 | M/S JAINENDRA KUMAR JAIN L2 | JAYESH ASSOCIATE AND DEVELOPERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Labour only for taking down street light/security light/garden light/flood light from any position, checking the serviceability of different spares / components / parts of security light fittings LED light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
NOTES FOR SCH `A’ ITEM NO 1:-
(i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’.
(ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. | 250 | EACH JOB | 100 ₹25,000 Lowest | 200 ₹50,000 | 230 ₹57,500 |
| 2.00 | Labour only for extension of street light bracket from any position to upper most position to making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
(i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’.
(ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. | 250 | EACH JOB | 150 ₹37,500 Lowest | 150 ₹37,500 Lowest | 150 ₹37,500 Lowest |
| 3.00 | Supply only following materials suitable for various type of street light, security light for replacing against item no 1 here in before. Make of spares CG,Philips,Wipro
(a) LED Lamp suitable for 9 W light fittings. | 50 | EACH | 150 ₹7,500 | 95 ₹4,750 | 90 ₹4,500 Lowest |
| 3.01 | (b) Driver for 45 Watts LED street light luminaries complete. Make : CG or equivalent in Legrand/ L & T | 50 | EACH | 450 ₹22,500 Lowest | 550 ₹27,500 | 800 ₹40,000 |
| 3.02 | (c) Driver for LED street light / Flood light luminaries 90 to 125 Watt complete. Make : CG or equivalent in Legrand/ L & T | 50 | EACH | 850 ₹42,500 | 580 ₹29,000 Lowest | 1,000 ₹50,000 |
| 3.03 | (d) Driver for 135/150 Watts LED flood light luminaries complete. Make :CG CG or equivalent in Legrand/ L & T | 20 | EACH | 1,250 ₹25,000 | 1,050 ₹21,000 Lowest | 1,100 ₹22,000 |
| 3.04 | (e) Driver for Garden Light Bollard 10 Watt Make : CG or equivalent in Legrand/ L & T | 80 | EACH | 350 ₹28,000 | 345 ₹27,600 Lowest | 350 ₹28,000 |
| 4.00 | Taking down old unserviceable Street Light fittings and Supply fixing 90W LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must havepeanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 85Lumen/Watt (Minimum lumen output of luminaire should be3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire.
Make : CG TRP-425-90-57-HL2-LM-NBK or eqivalent in Wipro and Philips. | 23 | EACH | 3,250 ₹74,750 Lowest | 3,450 ₹79,350 | 5,000 ₹1,15,000 |
| 5.00 | Supply and fix bracket for street light fittings made out GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed. | 40 | EACH | 650 ₹26,000 | 550 ₹22,000 Lowest | 800 ₹32,000 |
| 6.00 | Taking down of Monkey guard ( which are fixed to protect the Bollard light), , pereparing suface for painting, painting of Monkey Guard with black synthetic enameled paint two coat and re-fixing in original position including minor repair to PCC foundation etc complete all as specified and as directed.
Note :- The quoted rates shall deemed to be included rates for Nuts bolts, paint, cement, aggregate and sand. | 45 | EACH JOB | 150 ₹6,750 | 50 ₹2,250 Lowest | 100 ₹4,500 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL RAVI KUMAR PATIYAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTENANCE OF VARIOUS TYPE OF STREET LIGHT, BOLLARD LIGHT FITTINGS AT MAINTENANCE COMMAND COMMUNICATION FLIGHT, 22 PROVOST AND SECURITY, AKSC VAYUSENA NAGAR, NAGPUR
2026_MES_747662_1
8799/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹40,000
9 Mar 2026
8 Jan 2026
31 Jan 2026
8 Jan 2026
29 Jan 2026
22 Jan 2026
Labour only for taking down street light/security light/garden light/flood light from any position, checking the serviceability of different spares / components / parts of security light fittings LED light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. NOTES FOR SCH `A’ ITEM NO 1:- (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
Labour only for extension of street light bracket from any position to upper most position to making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
Supply only following materials suitable for various type of street light, security light for replacing against item no 1 here in before. Make of spares CG,Philips,Wipro (a) LED Lamp suitable for 9 W light fittings.
(b) Driver for 45 Watts LED street light luminaries complete. Make : CG or equivalent in Legrand/ L & T
(c) Driver for LED street light / Flood light luminaries 90 to 125 Watt complete. Make : CG or equivalent in Legrand/ L & T
(d) Driver for 135/150 Watts LED flood light luminaries complete. Make :CG CG or equivalent in Legrand/ L & T
(e) Driver for Garden Light Bollard 10 Watt Make : CG or equivalent in Legrand/ L & T
Taking down old unserviceable Street Light fittings and Supply fixing 90W LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must havepeanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 85Lumen/Watt (Minimum lumen output of luminaire should be3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire. Make : CG TRP-425-90-57-HL2-LM-NBK or eqivalent in Wipro and Philips.
Supply and fix bracket for street light fittings made out GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Taking down of Monkey guard ( which are fixed to protect the Bollard light), , pereparing suface for painting, painting of Monkey Guard with black synthetic enameled paint two coat and re-fixing in original position including minor repair to PCC foundation etc complete all as specified and as directed. Note :- The quoted rates shall deemed to be included rates for Nuts bolts, paint, cement, aggregate and sand.
Taking down Unserviceable Junction Box of street light for repair/replacement of wiring, connector, thimbles and copper wire 1.5 sqmm three core upto street light. Refixing of Junction Box after repair with new nut/bolts, locking arrangement and clamp with suitable size as directed. Note :- The quoted rates shall deemed to be included rates for minor spare of Juction box nuts/bolts, conn.have been included in Item rate of this item.
Taking down unserviceable Junction Box of Garden Light for repair/replacement of wiring, connector, thimbles and copper wire 1.5 sqmm three core upto street light. Refixing of Junction Box after repair with new nut/bolts, locking arrangement and clamp with suitable size as directed. Note :- The quoted rates shall deemed to be included rates for minor spare of Juction box such CI nuts/bolts, clamp, locking arrangement wire etc.
Taking down old unserviceable UG cable and Supply & Laying for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq mm, 4 core in trenches or fixing in walls / poles or drawing through pipe including testing after laid and jointed all as specified and as directed.
Taking down old unserviceable UG cable and Supply & Laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
All as per item No 9 above but of size 10 sq mm 4 core
All as per item No 9 above but of size 6 sq mm 2 core
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Material and labour for Double wall corrugated High density polyethylene pipes (HDPE) of size 50 mm dia laid in trenches for passing of LT cable complete all as specified and directed.
Material and labour for PCC cable route indicator in mix of 1:2:4 type B1 of size 450x200x75mm with oval shape and writing the letter LT cable with synthetic enamel paint and embedded with PCC foundation type D2 1:4:8 of size minimum 250 mm depth including necessary earth work complete all as specefied and directed.
Material and labour for road cutting manually not less than 200 mm wide and 150 mm deep including making good to distrubed surface after the completion of work with PCC 1:2:4 type B-2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc all as specified and as directed.
Material and labour for galvanised iron tubing dia light grade of size 40 mm dia with all fitting laid under floor / road crossing or in trenches or fixed to pole /walls with clamps as required including sealing of pipe ends with approval sealing compound etc complete all as specified and directed.
Material and labour for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, cable duct, cover slab and benching including all necessary form works complete all as specified and directed.
Dismantling and Taking down old unserviceable cable junction boxes and Supply and fix thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 210x155x92 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sq mm 04 core cable with RYB cable terminal Bloack and all as specified and directed . Make- Hansel Cat No DK 1600 G or equivalent in Neptune/ sintex
Dismantling and taking out old unserviceable cable junction boxes and Supply and fixing thermoplastic cable junction boxes IP 66 "halogen free and weather proof" for outdoor Installation with metric knockout for cable entry of size130 x180x77mm fixing on pole with MS clamps, nut bolts, washers and glands suitable for 6 Sq mm 02 core cable with RYB cable terminal Block including taking down old unserviceable cable junction boxes all as specified and directed. Make - HENSEL Cat No DK-1000G or equivalent in Neptune/ sintex
Supply and fix automatic street light Control Switch using infrared sensor based NATURE SWITCH for automatic switching of street light, Three phase load of 12-15 KW (navdeep -66- 12kW3P-Dual) with 3 Nos Contactors, 3 Nos Incoming MCB, 3 Nos Outgoing MCB of capacity 32 Amps each & 3 nos Contractors(SP/2- pole/3-pole) of 32 Amp & circuit wiring (Copper) of 10 Sqmm Nature switch operation should be based Nature light Lux level. provision for Manual Operation i.e Sensor By-Pass Option setting features complete all as specified and directed. Make: M/s Healer Enterprises (Brand- Swadeep) or equivelnt in L & T/ Havells/ Legrand/ Novatuer Electricals
Taking down old unserviceable copper wire, Supply and fix 3 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Taking down old unserviceable GI pipe, Supply and fix 15 mm dia GI tubes light grade with all fitting from junction box to street light fittings with clamps, nuts & bolts complete all as specified and as directed
Taking down old unserviceable PVC wire, material and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 4 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Taking down old unserviceable PVC wire, material and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 6 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Taking down old unserviceable PVC wire, material and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 10 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Dismantling and Taking out old unserviceable time switch and Supply and fix astro time switch for controll street light 3P module,24 hours program,with battrey back up of 100 hours complete all as specified and as directed. Make : L&T Cat No Cat No AUTS02AST00 or equivalent in Legrand / Siemens
Dismantling and Taking out old unserviceable time switch and Supply and fix analog time switch for controll street light 3P module,24 hours program,with battrey back up of 100 hours complete all as specified and as directed. Make : L&T AUTS03ANA00 or equivalent in Legrand / Siemens
Dismantling and Taking out old unserviceable contactor and Supply and fix power contactor 4 pole 415 Volts,40 Amps , MCX 04 coil voltage of rating 240 Volts including taking down old unserviceable power contactor complete all as specified and as directed. Make:- L&T Cat NoCS97012 or equivalent in Legrand / Siemens
Dismantling and Taking out old unserviceable contactor and Supply and fix power contactor 2 pole 240 Volts,40 Amps , MNX 40-2P coil voltage of rating 240 Volts including taking down old unserviceable power contactor complete all as specified and as directed. Make :L&T Cat NoCS90242 or equivalent in Legrand / Siemens
Dismantling and Taking out old unserviceable contactor and Supply and fix single pole contactor 240 Volts,40 Amps , MR 13 Type coil voltage of rating 240 Volts including taking down old unserviceable power contactor complete all as specified and as directed. Make :-L&T Cat NoCS94992 or equivalent in Legrand / Siemens
Taking down old unserviceable, Supply & fixing MCB TPN 32 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed Make : Legrand 4086 58 or equivalent in Legrand / Siemens
Material and labour for preparing surfaces of street light poles of any type size including street light brackets, bracket clamps, cable protection pipe, terminal box, stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely including painting strips on poles with one coats of sky blue and white synthetic enamel paint complete all as specified and as directed.
Material and labour for stickering of pole No. with letters of size 15 Cm height on pole/ plate complete all as specified and as directed.
Dismantling and Taking out old unserviceable Garden/ Pathway Light fittings and Supply & fix of Integral LED Ground mounted Bollard of 10 watt Inverted pyramid tripod led bollard with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser complete all as specified and as directed. Make:- CG Cat No.LBLSN-10-CDL or equivalent in Philips/ Havells/ Wipro.
Dismantling and Taking out old unserviceable Garden/Pathway Light fittings and Supply, Installation, Testing and Commissioning of Integral LED Ground mounted Bollard Inverted LED bollard 10 W with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser complete all as specified and as directed. Make:- CG Cat No.LBLA3-10-CDL or equivalent in Philips/ Havells/ Wipro.
Dismantling and Taking out old unserviceable street Light fittings and Supply, Installation, Testing and Commissioning of Integral LED street light luminarie 45 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (4kV), open and short circuit protection. system wattage 45 W and power lumen efficacy 120 lum/w complete all as specified and as directed.
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 150 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 150 W and power factor 0.90. Make TFS-510-150-57-60D-HL2-LM-NGG or equivalent in Philips/Havells/ Wipro.
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 50 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 60 W and power factor 0.90. Make CG TFS-504-50-57-NL-SL-GL-NBK or equivalent in Philips/Havells/ Wipro.
Dismantling and Taking out old unserviceable Post Top Light fittings and Supply and fixing in replacement for Post Top latern fitting of 40 W with LED Decorative indirect posttop for garden,Gate,landscape lighting. IP 65 protection.Resistant to impact and corrosion. Glare-free and better uniformilty and complete all as directed by Engineer-in-Charge Make : CG Cat No LPTO-40-CDL -M or equivalent in Philips/Havells/ Wipro.
Taking down old unserviceable Post Top lantern fitting Supply and fixing Post Top lantern fitting with LED lamp12 Watts opal acrylic diffuser and accessories including nut, bolt, washers all as specified and directed.
Taking down old unserviceable light fittings, Supply & fixing of Spike Garde LED light 12 Watt (Green Colour) die cast aluminium housing black colouree floor mounted outdoor use, colour green, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 12 + 10% Rated Frequency- 50Hz, luminus flux - > 1200 Lm, LED light source - SMD,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), 6000 K(WH) Working Temperature - 0oc to 500c , Rated life > 40,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV including taking down Make : Luker (Product Code- LSSPK12W\ ) /CG / Philips/ GE
Taking down old unserviceable light fittings,Supply & fixing pathway LED light 6 Watt die cast aluminium housing silver gray floor/Wall recess mounted outdoor use, colour warm white, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 6W + 5% Rated Frequency- 50Hz, luminus flux - > 400 Lm, LED light source - SMD, Beam Angle-60 deg, Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV including taking down Make : Luker (Product Code-LOUR6)/ CG / Philips/ GE
Taking down old unserviceable light fittings,Supply & fixing of outdoor garden light 20W die cast aluminium housing dark gray surface mounted Flood light outdoor use, colour warm white, Input Voltage-AC 100V-265V, PF-> 0.9, Power consumption 20W + 10% Rated Frequency- 50Hz, luminus flux - > 2000 Lm, LED light source - COB,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV Make: Luker (Product Code-LODSP20)/CG/ Philips/ GE
Taking down old unserviceable light fittings,Supply & fixing of outdoor Wall light 2 x 3W die cast aluminium housing dark gray wall mounted outdoor use, colour warm white 3000K, Input Voltage-AC 140V-265V, PF-> 0.9, Power consumption 6W + 10% Rated Frequency- 50Hz, luminus flux - > 600 Lm, LED light source - COB,Color Rendering Index (CRI) > 80, Colour Temperature - 3000K(WW), Working Temperature - 0oc to 500c , Rated life > 50,000 hrs, IP rating-IP65, Surge Protectio Upto 3KV Make: Luker (Product Code-LODSQUPD10D)/CG/ Philips/ GE
Material and labour for double drum winch 350 kg load for high mast light to move upward and downward for repair purpose complete all as specified and directed.
Material and labour for fixing for trailing cable copper armoured 5 core 2.5 Sqmm for high mast light complete all as specified and directed.
Material and labour for stainless steel wire rope 6 mm for high mast light complete all as specified and directed.
Material and labour for 0.75 HP motor for to move upward and downward to high mast light complete all as specifed and directed. Make : CG/KIRLOSKAR/CALAMA/KSB
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 250 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat with toughened glass cover having system limen output>27500 lumens, All LEDs are Osram LEDs with individual lens, input voltage working range is 120Vac to 280 Vac with upper limit cut of at 300Vac, Fixture can with stand for 8hr in case of High voltage fault upto 400Vac, potted drivers is used with 4KV internal surge protection, Short Circuit Protection, Open Circuit Protection, High & Low voltage protection with one External 10KV External Surge protection, Fixture is IP66 protected & IK08 procted, THD<10%, CCT 5700+/-300K, PF>0.9, cable entry through PG9 Cable gland. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Make : CG CFS-506-250-57-60 SL-GL-NSG or eqivalent Wipro and Philips.
Labour, T&P and material for Cleaning of Solar Panel of Solar hybrid LED Street of capacity 50 Watt att by using Solar panel cleaner and stain remover to remove foreign deposit, dust, silth, and stain etc for optimum generation. All as specified and as directed. Note :- cleaning material, / labour and Vehicle with hydrolic standing platform or any other T&P required for the same shall be deemed to be included in the quoted rate.
Material and labour for taking U/S Solar LED hybrid street litght from pole and checking for serviceability of parts and replacing the unserviceable parts and re-fixing the same in original position and testing complete all as specified and directed.
Supply only Battery Lithium-ion 12.8V(LFP) for 50 Watt Solar hybrid Street LED Light of complete all as specified and directed. Make Crompton Model No CGSALFP42AHF or eqivalent Wipro and Philips.
Supply only Charge controller for 50 Watt Solar hybrid Street LED Light of complete all as specified and directed. Make Crompton Model No CSAHSMP50CDL or eqivalent Wipro and Philips.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_837296.xls
BOQ • 0.40 MB
TENDERDOCS8799.pdf
Tender Documents • 0.38 MB
CRIEDIT8799.pdf
Tender Documents • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .