| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹7.2 L+₹1.1 L (17.6%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 3 | L3₹8.7 L+₹2.5 L (41.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 4 | L4₹9.1 L+₹2.9 L (47.8%)Rejected-Finance 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L4 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 5 | L5₹9.3 L+₹3.1 L (50.5%)Rejected-Finance | L5 | Rejected-Finance HIGHER AMOUNT QUOTED |
Tender Value
₹8.7 L
EMD Value
₹17,480
Closing Date
21 Sept 2020, 6:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR OF U/G AND O/H LINE, TRANSFORMER AND MISC WORK FOR DISTRIBUTION SYSTEM OF EXTERNAL ELECTRIFICATION IN ARMY AREA AT MOUNT ABU UNDER AGE(I) UDAIPUR
2020_MES_368680_2
8548/E8/AGE I UDAIPUR
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ARMY AREA MOUNT ABU
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹17,480
Yes
19 Dec 2020
5 Sept 2020
23 Sept 2020
5 Sept 2020
21 Sept 2020
8 Sept 2020
Amount
Dismantling insulator, any size from LT poles and removing from site all as specified and directed.
Dismantling of cross arms of MS channel or angle section etc and removing from site or setting aside for reuse complete all as specified and directed.
Material & labour for PCC 1 : 3 : 6 type C-2 using 40mm grade stone aggregate for foundation of stay/pole/ strut as per specified and directed.
Material & labour for PCC 1 : 3 : 6 type C-1 using 20mm graded stone aggregate for pedestal including necessary from work including finishing to exposed surface even and smooth without using extra cement complete all as specified and directed. Note for item No 3 & 4 : Volume of pole/ strut embedded in concrete shall be deducted for the purpose of payment.
Material & labour for cross arms, bracing, supports, back plate & clamps fabricated from structural steel section including nuts, bolts, washer cuttings, welding bending cold or hot, drilling holes for bolts in any shape for bolts in any shape or size inclusive of painting with 2 coats of aluminum paint over a coat of primer complete all as specified and directed.
Material & labour for pin type, porcelain vetreous white, brown or insulators incl one gaivanized MS spindle, two galcanized iron washers & one GI nut, 100mm height, 65mm dia, 1100 Volts grade complete all as specified and directed.
Material & labour for shackle type insulator, porcelain vetreous white, incl gaivanized MS strips washers & nuts working pressure 1100 Volts, 100mm high and 115mm dia complete all as specified and directed.
Dismantling and carefully taking down and Material & labour for galvanized steel stranded stay wire of any size for stay of poles including necessary clamps of 50 x 6mm FI and bolts nuts of suitable size complete all as specified and directed.
Dismantling and carefully taking down and Material & labour for 8 SWG (4mm dia/or nearest) mild steel, galvanized wire laid for earth continuation main guarding wire with cardle including straining properly and binding with steel winding complete all as specified and directed.
Stringing and tightening only aluminium conductor steel reinforced (ACSR) any size, straining properly on insulators and binding with aluminium binding wire on the existing HT/LT poles complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 120 sqmm
Matrial & labour for repair of GO to smooth operation & alighment of contacts, connect/tighting of HT cable including greasing of moving mechanism, replacement of Male contact/moving contact blade, female contact/fix contact jaw, tinned copper flexible jumper, MS jumper carrier, back connector plate where required and replacement of handle/lever, nut-bolts washers etc. of required size and length and testing all as specified and directed by Engr-in-charge.
Excavating in trenches n.exc 1.50mtr wide and n.exc 1.5mtr in depth for foundation/ pipes/ cables etc, n.exc 10sqm on plan and n.exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in soil complete all as specified and directed.
Removing of excavated surplus soils, n.exc 50mtr and depositing where directed at a level n.exc 1.50mtr above the starting point complete all as specified and directed.
Material & labour for sand cushioning for PVC cable with screened and washed sand and punning to provided a required covers all as specified and directed.
Material & labour for brick protection cover to LT under ground cable with old size sub class 'B' bricks laid dry width equal to length of brick abouting each other with gaps between adjacent brick not exc 10mm al1 as specified and directed.
M & L for cutting of tree-branches touching HT/LT OH lines having girth exc 30cm and n.exc 100cm and disposal of the branches to a distance n.exc 50mtr and clearing the site all as specified and as directed.
M & L Painting of old surface and applying two coats of aluminiuim paint over a coat of zinc chrome primer to existing MS channel, clamps, etc on existing any type of poles of 9/11 mtr all as specified and directed.
M& L Painting of old surface and applying two coats of black and white as Zebra crossing, white painting of pedestal etc on existing RCC poles of 9/11 mtr all as specified and directed.
De-Hydration and filtration of transformer oil of the transformer, and Voltage stablizer, AC, 11KV/433 Volts mounting on 2 pole/4 pole structure/platform from all as specified and directed by Engineer- in- charge.
Topping the transformer with new transformer oil of dielectric strength more than 50 KV, mounting on 2/4 pole structure/plate from all specified & directed by Engineer-in-charge.
Painting of Transformer 11/0.433 KV form painting out side with two coats of synthetic enamel grey paint after scraping old painted surfaces complete all as specified and directed of cap. Upto 315 KVA.
Replacement of breather including sillica gel for transformer of capacity 63/ 250/ 315 KVA complete all as specified & directed.
Repair to DG Set 15-25 KVA with prime mover water cooled engine 4 stroke vertical dismantling of head assy and carrying out over hauling of the engine by repair and replacement of the following parts :- (a) Repalcement of fuel filter element - 01 No (b) Repalcement of oil & oil filter (c) Repair to engine panel wiring by replacement of wire looms, indicator lamp etc. (d) Replacement of tappet cover gasket - 01 set (e) Tightening of head stud nuts - 01 set (f) painting of complete DG set after cleaning and testing after repair as directed by Engr-in-Charge. (g) Battery 90 AH and Charger.
Supply & Fixing in repair of following items in existing LT panel boards and testing of complete panel after repair all as specified and directed.
Phase indicating lamp neon type complete with contact block & holder assembly RYB
Volt meter for 3 phase supply 0-500
Ameter for 3 phase load range 0-400
Supply & Fixing MCCB, 415 Volts, 3 Phase,with necessary modifications in Panel Board for connection of MCCBs complete all as directed including connecting and testing of the following capacity :-
160 Amps, 36 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts, Make : ABB/Legrand/Schneider
100 Amps, 16 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts,Make : ABB/Legrand/Schneider
63 Amps, 16 KA breaking Capacity,4 Pole, 50 Hz, 415 Volts, Make : ABB/Legrand/Schneider
M & L spray painting the existing LT panel boards outdoor type of any size with two coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. The panel door shall be painted internally and externally both and remaining portion of the panel shall be painted externally only.
M&L for repair of LT panel inner/outer doors by replacing of door hinges, handle, locking arrangement & misc work for smooth operation of panels doors.
Disconnecting and taking out carefully existing defective copper cables from panel boards and Supply, fixing & testing PVC insulated multi stranded copper conductor heavy duty 1100 Volts grade single core LT cable of size 16 Sqmm for connection between bus bar and main switch of LT panel board or alternator to panel board including providing solderless copper thimbles complete all as directed.
M&L Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size.
M&L Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm .
Dismantling old unserviceable LT poles, any type/size and removing from site complete all as directed.
Dismantling stay assembly complete, any type, any size complete making good disturbed surfaces and removing from site as per specified and directed.
Supply and errect in position 9.00mtr long PCC poles of cross section 102x172mm at top and 102x279mm at bottem, class 10, conforming to IS-1678-1978 complete all as specified and directed.
Supply & fix stay assembly comprising of stay bow galvanized 14mm dia x 400mm long, stay rod 16mm x 2.15 meter long with nuts, bolts, washer, mild steel galvanised stay plate of size 30cm x 30cm x 6mm thickness, two Nos thimble and clamps etc complete all as specified in electrical No 1 of SSR Part-I. Note for item 35 & 36 : Loop type insulator, excavation & earth work and concrete foundation shall be measured and paid separately under respective of Sch 'A'
Repair to DG Set 15-25 KVA with prime mover water cooled engine 4 stroke vertical, repair of alternator and balancing of engine, dismantling of head assy and carrying out over hauling of the engine by repair and replacement of the following parts :- (a) Repalcement of fuel filter element - 01 No (b) Repalcement of oil & oil filter (c) Repair to engine panel wiring by replacement of wire looms, indicator lamp etc. (d) Replacement of tappet cover gasket - 01 set (e) Tightening of head stud nuts - 01 set (f) painting of complete DG set after cleaning (g) replacement of battery 90 AH & charger, asssemble & refix on plaform including rubber absorber etc and testing all as specified & directed by Engr-in-Charge.
Supply and laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm
Repairing of LED street light by tightning of jumper/replace wheather proof cable or taking down carefully from LT pole or building of any make/model & watt and deposite to MES store for repair and refixing.
Dismentling of security light fitting and repair by replacing LED drive set, wheather proof cable, bolts-washers and refixing at specified location and testing complete all as directed. (LED driver & cable measured and paid seperately)
Supply and fixing of LED security light driver for 48 w
Supply and fixing of LED security light driver for 60/70 w
Supply and fixing of LED security light driver for 90 w
Taking down old unsv security fitting and Supply & fixing Pressure die cast aluminum housing Heat resistance toughened glass 60 W IP 66 protection better optics for uniform distribution LED Street light Make : Crompton/ PHILIPS/BAJAJ
Supply and fix & connecting PVC insulated cable weather proof twin core having aluminium stranded conductor of size 2.50 sqmm, 1100 volts grade as per IS 694 as per ISI marked for street light fitting to over head lines.
Taking down and removing Old pipe bracket of any size and length and supply and fixing GI pipe bracket made of GI pipe 25/32 mm dia 1.20 mtr length light grade bent to shape.
Taking down old unsv garden light and Supply & fixing LED garden bollard light 1 x 10 Watt.Make:-CG Cat Part No LBLS1-10-CDL or as approved by Engineer-in-charge with necessary connection and PCC work for foundation.
Taking down old unsv garden light 1 x 10 Watt.Make CG Cat Part No LBLS1-10-CDL and replace complete driver set & rectify other defect and refixing, testing including necessary PCC work for foundation, complete all as directed by Engr-in-charge.
Taking down old lamp type Post top fittings and Supply & fixing 40 W LED gate light fitting, IP 65 protection, Resistant to impact and corrosion, Glare-free and better uniformity including drilling holes, necessary electric connections & PVC protection pipe all as directed. Make :- Crompton/ PHILIPS / BAJAJ approved by Engr-in-charge
Taking down haigh mast light and replacement of unsv lights with LED flood light luminaire with high IP65 PDC floodlight aesthetically designed. Make : CROMPTON CAT part LFLN-120-CDL/60 or equaivalent of PHILIPS/BAJAJ approved by Engr-in-charge.
Supply and lay cable protection pipes galvanised 'Light grade' supplied and laid complete incl fittings 40 mm dia.
Material & labour for XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 2 core complete with lugs and clamps all as specified & directed.
Supply and fix Sheet metal enclousers 2 way for DB,s when MCBs to be used single pole & neutral 240 volts.
Taking down and removing of old unsv clamps of any size and S & F supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as directed.
Supply and fix MCB 16/20 Amps SPN, 240 volts.
Supply and fix MCB 32 Amps SPN, 240 volts.
Supply & fixing of MCB TPN 40/63 Amp
Material & labour for Jali as per sample, made of angle iron & wiremesh, size of jali as per existing size of pillar and light fitting for protection of gate light fitting fixing by drilling holes and suitable size of nut bolts-washers and necessary PCC work all as per directed .
M/S Balkishan Panwar Construction
Choudhary Traders and Engineers
shri balaji trading corporation
boon construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .