| 4 | Schedule 4 | AADI HEALTH CARE | 1 | ₹75.8 L |
| 5 | Schedule 5 | AADI HEALTH CARE | 1 | ₹75.8 L |
Tender Value
₹3.3 Cr
EMD Value
Exempted
Closing Date
22 Jan 2026, 4:00 pmClosed
Size 6 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction
Size 7 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction
Size 8 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction
Size 7 Spiral reinforced soft and flexible tube with adjustable neck flange with a practical push button mechanism with cuff embedded subglottic suction scale and 15 mm connector
Size 8 Spiral reinforced soft and flexible tube with adjustable neck flange with a practical push button mechanism with cuff embedded subglottic suction scale and 15 mm connector
8677360
GEM/2025/B/6969200
Two Packet Bid
Size 6 Polyurethane made Tracheostomy Tube with cuff
Delhi; South, Delhi; South Delhi
Item wise evaluation
BOQ
7 documents required · 7 mandatory
2 yrs
₹1.6 Cr
₹1.6 Cr
20%
DIRECTOR, Safdarjung Hospital, Department of Health and Family Welfare, Central Health Service Ministry of Health and, Family Welfare, Ministry of Health and Family Welfare, (Director)
Exempted
22 Jan 2026
1 Jan 2026
22 Jan 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Size 6 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction | Tracheostomy tube should be made up of thermosensitive Polyurethane and DEHP free material The size of the Tracheostomy tube should correspond to the inner diameter of the inner cannula For e g In 7 mm of tube size the inner diameter of the inner cannula should also be 7 mm The tube should also have a low pressure cuff and subglottic suction The tube should be supplied with 2 inner cannulas with white 15 mm connector 2 connectors for suction devices a perforated obturator and a neck strap The useful life of the tube should be 29 days from first use The tracheostomy tube should have Double swivel neck flange movable and swivels in both vertical and horizontal directions following the patients desired head movements The forward angled eyelets in the neck flange allow application of threading the neckband The shelf life should be 5 years | 12 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 2 | Size 7 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction | Tracheostomy tube should be made up of thermosensitive Polyurethane and DEHP free material The size of the Tracheostomy tube should correspond to the inner diameter of the inner cannula For e g In 7 mm of tube size the inner diameter of the inner cannula should also be 7 mm The tube should also have a low pressure cuff and subglottic suction The tube should be supplied with 2 inner cannulas with white 15 mm connector 2 connectors for suction devices a perforated obturator and a neck strap The useful life of the tube should be 29 days from first use The tracheostomy tube should have Double swivel neck flange movable and swivels in both vertical and horizontal directions following the patients desired head movements The forward angled eyelets in the neck flange allow application of threading the neckband The shelf life should be 5 years | 1,062 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 3 | Size 8 Polyurethane made Tracheostomy Tube with cuff Swivel neck flange and subglottic suction | Tracheostomy tube should be made up of thermosensitive Polyurethane and DEHP free material The size of the Tracheostomy tube should correspond to the inner diameter of the inner cannula For e g In 7 mm of tube size the inner diameter of the inner cannula should also be 7 mm The tube should also have a low pressure cuff and subglottic suction The tube should be supplied with 2 inner cannulas with white 15 mm connector 2 connectors for suction devices a perforated obturator and a neck strap The useful life of the tube should be 29 days from first use The tracheostomy tube should have Double swivel neck flange movable and swivels in both vertical and horizontal directions following the patients desired head movements The forward angled eyelets in the neck flange allow application of threading the neckband The shelf life should be 5 years | 1,056 | pieces | Gajendra Singh Practical Push Button Mechanism 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 With Cuff Embedded | 180 |
| 4 | Size 7 Spiral reinforced soft and flexible tube with adjustable neck flange with a practical push button mechanism with cuff embedded subglottic suction scale and 15 mm connector | Spiral reinforced soft and flexible tracheostomy tube with adjustable neck flange with a practical push button mechanism low pressure cuff embedded subglottic suction scale and 15 mm connector The tube should also have a X ray contrast line The tube should have a variably adjustable neck flange The neck flange should be able to move on the cannula with the help of a practical push button mechanism The neck flange should be locked unlocked by moving the lever upward downward The flexible wings on the neck flange should be able to be adjusted independently of one another to accommodate the individual patients anatomy The tube shouldf be equipped with an embedded subglottic suction The opening of the subglottic suction should be at the lowest possible point above the cuff The tube should be supplied with 2 connectors for suction devices Obturator Adjustable neck strap and Product info card with two detachable labels The useful life of the tube should be 29 days from first use and the material should be DEHP free The shelf life should be 5 years | 1,263 | pieces | Gajendra Singh Practical Push Button Mechanism 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 With Cuff Embedded | 180 |
| 5 | Size 8 Spiral reinforced soft and flexible tube with adjustable neck flange with a practical push button mechanism with cuff embedded subglottic suction scale and 15 mm connector | Spiral reinforced soft and flexible tracheostomy tube with adjustable neck flange with a practical push button mechanism low pressure cuff embedded subglottic suction scale and 15 mm connector The tube should also have a X ray contrast line The tube should have a variably adjustable neck flange The neck flange should be able to move on the cannula with the help of a practical push button mechanism The neck flange should be locked unlocked by moving the lever upward downward The flexible wings on the neck flange should be able to be adjusted independently of one another to accommodate the individual patients anatomy The tube shouldf be equipped with an embedded subglottic suction The opening of the subglottic suction should be at the lowest possible point above the cuff The tube should be supplied with 2 connectors for suction devices Obturator Adjustable neck strap and Product info card with two detachable labels The useful life of the tube should be 29 days from first use and the material should be DEHP free The shelf life should be 5 years | 1,263 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8677360.pdf
GEM_BID
boq_item_sample_file_-10_2025-12-05-12-53-17_abde94c6c291647c21d66d2f62fd6d5f.pdf
BOQ
boq_item_sample_file_-10_2025-12-05-12-53-17_03dd4e4437129c6cff06e3da127e8b0b.csv
BOQ
Integrit_14cb8f10-428e-4df9-8e111764921776519_SURGICALCONSUMABLE@SJH.pdf
OTHER
blacK_1f4e3c14-4a7f-4157-aec61764921817921_SURGICALCONSUMABLE@SJH.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Integrit_14cb8f10-428e-4df9-8e111764921776519_SURGICALCONSUMABLE@SJH.pdf
GEM_OTHER • 0.12 MB
blacK_1f4e3c14-4a7f-4157-aec61764921817921_SURGICALCONSUMABLE@SJH.pdf
GEM_OTHER • 0.23 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.70 MB
Download all tender documents and submit your bid